ENVION TPP220H UV Air Purifier Instruction Manual
- June 6, 2024
- ENVION
Table of Contents
TPP220H UV Air Purifier
Instruction Manual
Thank you for purchasing the Therapure® 220H air purifier. With UV light and
cleanable Cleanable HEPA-Type filtration to clean the air, the Therapure® 220H
air purifier will greatly improve the quality of the air in your home, office,
or other environments. We want you to be fully satisfied with your Therapure®
220H.
That’s why your Therapure® 220H comes with a one-year limited warranty.
Once you’ve experienced the purity of Therapure® 220H air, visit us at our
website to find out more ways to improve the quality of your air and your life
with our premium products and upgrades.
Please be sure to read the following instructions carefully to ensure optimal
performance and safety.envion.com
Therapure® by BONECO North America Corp.
15821 Ventura Blvd. Suite 685
Encino, CA 91436
800.875.8577
SAFETY INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
WARNING: RISK OF ELECTRICAL SHOCK
Safety precautions should always be used when operating this or any electrical
appliance.
Decrease the risk of electrocution, electric shock, injury or fire by reading
and following all the warnings below.
Use only as described in this Therapure® 220H manual. To reduce the risk of
electric shock, do not attempt to service the product in any way other than in
the manner described in the “Cleaning & Maintenance” section of this manual.
READ ALL INSTRUCTIONS BEFORE OPERATING THE AIR PURIFIER.
-
This product operates at 120V AC, 60Hz only.
-
Do not run cord under carpeting. Do not cover the cord with throw rugs, runners, or similar coverings.
Arrange cord away from traffic area and where it will not be tripped over. -
Do not operate the product in any greasy environment, such as in the kitchen. This product is not intended to filter oil or grease from the air.
-
Do not use the Therapure® 220H air purifier in bathrooms or other humid environments. Do not use near fireplaces or in areas where flammable or combustible vapors or products may exist.
-
Always unplug the power cord from the electrical outlet when the purifier is not in use, before cleaning, inserting or removing parts or before moving to another location.
-
Never run the air purifier unless it is fully assembled.
-
This appliance has a polarized plug (one blade is wider than the other). To reduce the risk of electric shock, this plug is intended to fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Do not attempt to defeat this safety feature.
-
Always turn off all controls before unplugging the Therapure® 220H air purifier from the outlet.
-
Attempting to service the Therapure® 220H air purifier in any way that is not described in this owner’s manual will cause the warranty to be voided and could cause serious personal injury to the user and/or result in considerable damage to the unit.
-
Do not place the cord near a heated surface.
-
Do not operate this product with a damaged cord or plug. Discard the product or return to an authorized service facility for examination and/or repair.
-
Never use the power cord to pick up, carry, drag, pull, or lift the Therapure® 220H air purifier. Do not pull the cord against or around sharp corners and edges. This could result in injury to the user or damage to the cord.
-
Always remove the plug from its power outlet by holding onto the plug itself and pulling gently.
-
Never pull on the cord itself to unplug it from its power outlet.
-
Use care when operating the Therapure® 220H air purifier by keeping all foreign objects, fingers, body parts, hair, loose clothing, and jewelry away from openings.
-
Never touch the Therapure® 220H air purifier or its plug when your hands are wet.
-
The Therapure® 220H air purifier is an electrical appliance. Adult supervision is required when operating the Therapure® 220H in the presence of children.
-
To reduce the risk of fire or electric shock, do not use this air purifier with any solid-state speed control devices.
IMPORTANT WARNINGS
UV Lamp Notice
UV Light is harmful to bare skin and eyes and can cause temporary or cleanable
loss of vision. Never look directly at the UV lamp while it is illuminated;
doing so could cause loss of vision! Only view illumination through the window
at the front of the unit. To prevent exposure to ultraviolet light, disconnect
the power to the unit before servicing any part of the Therapure® 220H air
purifier.
UV Lamp Disposal
If the UV lamp breaks, turn off the unit. Do not operate the unit with a
broken lamp. Do not use a vacuum to clean up the breakage. Sweep debris into a
plastic bag and dispose of it properly. Contact your local waste management
authority for instructions regarding recycling and the proper disposal of old
lamp(s). To order a replacement lamp, call 1.800.875.8577 or go to
envion.com.
Mercury Notice
Because the Therapure® 220H contains a light bulb and light bulbs contain
mercury, Envion is required to provide the following warning:
WARNING: This product can expose you to Mercury, a chemical that is known
to the state of California to cause birth defects or other reproductive harm.
For more information, visit
www.P65Warnings.ca.gov.
Do not place your used lamp(s) in the trash. Disposal of any item containing
mercury must be in accordance with any hazardous waste disposal or recycling
laws and regulations of your state.
This product complies with the maximum allowable concentration of ozone of
0.050 parts per million by volume (ppmv) in a 24-hour period. The Health
Canada Guideline 2010 recommends that the maximum exposure limit, based on an
averaging time of 8 hours, is 0.020 ppmv or less when tested in a sealed,
controlled room approximately 30 m3.
PRODUCT BENEFITS
- Effectively reduces smoke, pollen, dust, VOCs, animal dander, dust mites, mold and bacteria.
- 3-speed fan setting–lets you select the desired cleaning level.
MAIN PARTS
1. Locking Latch | 7. UV Indicator Light |
---|---|
2. Air Inlet Grill | 8. UV/VOC Button |
3. Cleanable HEPA-Type filter: the filter removes small visible and non-
visible particles.| 9. Air Outlet Grill
4. UV Lamp Cover| 10. Base of Unit
5. Control Panel| 11. UV Lamp
6. Control Dial: 3 fan speed settings: (low, medium, and high).
OPERATING THE THERAPURE® TPP220H
Before using the Therapure® 220H air purifier, please read the following
important information.
Electrical Ratings:
- 120V Setting: 120Vac, 60 Hz
- Power consumption: 35 watts (0.5 amperes) at high fan speed,
- 3 watt UV light lamp
- Net weight: 5.2 lbs.
- Dimension (LxWxH): 9.6” x 7.9” x 17.25”
Replacement Parts:
Lamp – TPP2200
Filter – TPP220F
Locate a level surface on which to place the Therapure® 220H air purifier near a 120V outlet (follow warnings in the “ SAFETY INSTRUCTIONS” and “IMPORTANT WARNINGS” sections of this manual). Position your Therapure® 220H at least one foot (12 inches) from the wall. Plugin the unit.
Before using the Therapure® 220H air purifier, please read the following
important information.
Safety
- Do not place near fans.
- Keep both sides of the unit at least 1 foot away from a wall.
- Do not place the unit near curtains.
- Placing the unit close to the source of air pollution is an effective way to improve indoor air quality.
Note:
DO NOT run the Therapure® 220H with a broken filter. Replace the filter if the
filter has a tear or a hole in it.
If the filter is damaged or needs replacement, please visit the Therapure®
website at envion.com to order a replacement filter. Or
call 1.800.875.8577.
CONTROLS/SETTINGS:
Power Control – To operate the Therapure® air purifier, turn the Control
Dial clockwise to turn it on.
Speed Control – The Therapure® has three different speeds of cleaning,
LOW, MED, and HI.
Turn the knob ONCE for LOW, TWICE for MED, and THIRD for HI.
UV Control – Press the UV/VOC control button “UV/VOC” to turn on the UV
lamp.
Press it again to turn off the UV and VOC. A blue UV indicator light will
light up around the button when UV/VOC is turned on.
CLEANING & MAINTENANCE
Keep the Therapure® 220H functioning properly by cleaning the Cleanable HEPA-
Type filter every four weeks. More frequent cleaning will be necessary if the
unit is located in an area with a high level of airborne contaminants
(excessive amounts of smoke, pet dander, etc.).
Exposing the Therapure® 220H to candle/oil/fireplace soot and smoke is not
recommended and will require more frequent cleaning.
Note: Always make sure the Therapure® 220H is turned off and unplugged before cleaning.
- Vacuuming will restore the performance of the Cleanable HEPA-Type filter. However, the filter may appear stained. This is normal and does not affect performance in any way.
- Do not use water or any household cleaners or detergents to clean the Cleanable HEPA-Type filter.
- The inlet grill may be cleaned (after the unit is turned off and unplugged) with a vacuum or a slightly damp cloth.
Cleaning the Cleanable HEPA-Type filter (steps 1-4 shown).
- Release the inlet grill by pressing on the locking latch (see a diagram of Main Parts).
- Remove the inlet grille from the unit as shown below.
- Grasp the left and right frames of the Cleanable HEPA-Type filter through the indentations on the sides of the filter enclosure and remove the filter.
- To clean the Cleanable HEPA-Type filter, use the brush or crevice attachment with a vacuum cleaner. Run the attachment along the inlet and outlet side of the filter, cleaning between the crevices as much as possible. Do not use water or any household cleaners or detergents to clean the Cleanable HEPA-Type filter.
- Once the Cleanable HEPA-Type filter has been cleaned and checked for any possible damage, replace the filter back in the reverse direction described here.
Cleaning External Surfaces
- Turn off and unplug the unit.
- Use a washcloth slightly dampened with a little water and dishwashing soap to wipe the outer case surfaces.
- Do not allow water to slip into the internal parts as this could damage your unit and result in electrical shock and injury to you.
- Allow the unit to thoroughly dry before use.
UV Lamp
The lifetime of the UV lamp is up to 12 months of continuous, effective
operation. After this time, the bulb may remain illuminated, but its
effectiveness is greatly reduced. For maximum effectiveness, please replace
the UV bulb annually.
If the lamp stops functioning or needs replacement, please visit our
website at envion.com to order a replacement lamp.
Or call 1.800.875.8577.
Caution:
- Do not touch the glass part of the lamp. Oil from the fingertips will decrease the effectiveness of the lamp.
- Never operate the unit without a filter or with a damaged filter. UV lamp cover must be installed at all times. The UV light from the UV lamp will result in severe damage to the eyes and could cause blindness.
UV Lamp Notice Warning:
UV Light is harmful to bare skin and eyes and can cause temporary or cleanable
loss of vision.
Never look directly at the UV lamp while it is illuminated-doing so could
cause loss of vision!
Before replacing the UV lamp, make sure the Therapure® 220H air purifier is
turned off and unplugged. Let the lamp cool down for 5 minutes before
replacing it.
Replacing the UV Lamp:
- Release the inlet grill by pressing on the locking latch (see a diagram of Main Parts).
- Remove the two bolts used to fix the UV lamp cover and remove the cover from the unit.
- Unscrew the old UV lamp from the lamp base of the unit.
- Install the new UV lamp into the lamp base of the unit.
- Install the UV lamp cover with the two bolts on the unit.
- Install the inlet grill on the unit.
TROUBLESHOOTING
PROBLEM | REASON | SOLUTION |
---|---|---|
Unit will not operate | The power button has not been turned on. |
The unit is unplugged.
The inlet grill has not been installed & locked into place.| Press the Power
button.
Check to ensure the unit is plugged in.
Check to make sure the filter and inlet grill is properly installed & locked
into place.
Reduced airflow or poor filtering| The inlet or outlet grill may be blocked.
The cleanable filter may be clogged.| Check to ensure nothing is blocking the
air inlet & outlet.
Check & clean the filter, if necessary.
No visible light in the UV light view window| UV button is not turned on UV
lamp is broken| Check that the UV button is turned on Replace the UV lamp
ONE-YEAR LIMITED WARRANTY
ONE YEAR LIMITED WARRANTY
Your Therapure® 220H air purifier is warranted to be free from defects in
materials and workmanship for one year from the original purchase date. Should
the product have a defect in materials or workmanship, we will repair or
replace it without charge to you (a shipping and processing fee will apply).
To obtain service under warranty, simply call our customer service center
toll-free at 800.875.8577 | M-F 7-4 PST / 7-3 Sat.
This warranty does not cover damage caused by accident, misuse or any use
other than as intended and described in this product manual, or damage
resulting from failure to maintain and clean this product as specified in this
product manual. This warranty applies only to the original purchaser of the
Therapure® 220H air purifier.
ALL EXPRESS AND IMPLIED WARRANTIES FOR THIS PRODUCT, INCLUDING IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE
LIMITED IN DURATION TO THE WARRANTY PERIOD, AND NO WARRANTIES, WHETHER EXPRESS
OR IMPLIED, WILL APPLY AFTER THIS PERIOD.
Some states do not allow limitations on the duration of implied warranties, so
the above limitation may not apply to you. While this warranty gives you
specific legal rights, you may also have other rights which may vary from
state to state.
Contact Info for Warranty Service:
Therapure® by BONECO North America Corp.
15821 Ventura Blvd. Suite 685 | Encino, CA | 91436
1.800.875.8577 | envion.com
© 2020 BONECO North America Corp. All Rights Reserved. Patents Pending.
ARBITRATION AGREEMENT
PLEASE READ THIS AGREEMENT CAREFULLY. YOU ACCEPT THE TERMS OF THIS AGREEMENT
BY RETAINING THE PRODUCT(S) SHIPPED IN CONNECTION WITH THIS AGREEMENT (THE
“PRODUCTS”) FOR MORE THAN THIRTY (30) DAYS AFTER RECEIPT. IF YOU DO NOT AGREE
TO THE TERMS OF THIS AGREEMENT, YOU MAY RETURN THE PRODUCT TO THE COMPANY
WITHIN THIRTY (30) DAYS OF RECEIPT FOR A FULL REFUND.
THIS ARBITRATION AGREEMENT (“AGREEMENT”) CONTAINS A MANDATORY ARBITRATION
PROVISION THAT AFFECTS YOUR LEGAL RIGHTS AND REMEDIES BY PROVIDING THAT
DISPUTES BETWEEN YOU AND THE MANUFACTURER, DISTRIBUTOR, AND/OR SELLER OF THIS
PRODUCT (COLLECTIVELY, “COMPANY”), MUST BE RESOLVED THROUGH BINDING
ARBITRATION AND NOT IN COURT. IT ALSO PROVIDES THAT ANY DISPUTE CAN NOT BE
RESOLVED IN A CLASS ACTION OR OTHER PROCEEDING WHERE YOU REPRESENT OTHER
PERSONS OR OTHER PERSONS REPRESENT YOU AND THAT NO CLASS OR REPRESENTATIVE
ARBITRATIONS ARE PERMITTED. PLEASE CAREFULLY READ ALL TERMS IN THIS
AGREEMENT.
-
RESOLUTION OF CLAIMS OR DISPUTES.
Any claim or dispute between you and Company (or any of Company’s subsidiaries or affiliates) arising out of or relating in any way to the Product or this Agreement shall be resolved through final, binding arbitration. This arbitration obligation is reciprocally binding on both you and the Company and applies regardless of whether the claim or dispute involves a tort, fraud, misrepresentation, product liability, negligence, violation of a statute, or any other legal theory. Both you and Company specifically acknowledge and agree that you waive your right to bring a lawsuit based on such claims or disputes and to have such a lawsuit resolved by a judge or jury. -
LIMITATION OF LEGAL REMEDIES.
All arbitrations under this Agreement shall be conducted on an individual (and not a class-wide) basis, and an arbitrator shall have no authority to award class-wide relief. You acknowledge and agree that this Agreement specifically prohibits you and the Company from commencing arbitration proceedings as a representative of others or joining in any arbitration proceedings brought by any other person. The parties agree that no class or representative actions of any type are permitted. -
ARBITRATION PROCEDURES.
a. Before instituting an arbitration, if you have any dispute, we strongly encourage you to contact the Company to try to resolve the matter by calling 800-875-8577, although you are not required to do so.
b. The arbitration of any claim or dispute under this Agreement shall be conducted in accordance with the expedited procedures set forth in the JAMS Comprehensive Arbitration Rules and Procedures as those Rules exist on the date you receive the Product, including Rules 16.1 and 16.2 of those These rules and procedures are available by calling JAMS or by visiting its web site at www.jamsadr.com. The arbitration of any claim or dispute under this Agreement shall be conducted by an arbitrator who has at least five years of experience conducting arbitrations.
c. The arbitration of any claim or dispute under this Agreement shall be conducted in the State of California or the location in which you received this Agreement. For claims of Sio,000 or less, you may choose whether the arbitration proceeds in person, by telephone, or based only on submissions.
d. The Company shall pay costs for the arbitration of claims, including any JAMS Case Management Fee and all professional fees for the arbitrator’s services. The Company shall pay the fees and costs of its own counsel, experts, and witnesses and shall not be able to recoup them from you even if you do not prevail in the arbitration. Unless otherwise provided by law, you acknowledge and agree that you shall pay the fees and costs of your own counsel, experts, and witnesses. -
CHOICE OF LAW.
The arbitration provisions of this Agreement and any arbitration conducted pursuant to the terms of this Agreement shall be governed by the Federal Arbitration Act (9 U.S.C. Secs. 1-16). In this respect, the parties acknowledge that this Agreement involves a transaction conducted in interstate commerce. Otherwise, this Agreement and the rights of the parties hereunder shall be governed by and construed in accordance with the laws of the State of California, exclusive of conflict or choice of law rules. -
SEVERABILITY.
If any provision of this Agreement is declared or found to be unlawful, unenforceable or void, such provision will be ineffective only to the extent that it is found unlawful, unenforceable or void, and the remainder of the provision and all other provisions shall remain fully enforceable.
References
- ENVION - good for your health and home - ENVION
- JAMS: Mediation, Arbitration and ADR Services
- P65Warnings.ca.gov
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>