DELL PowerVault MD3400 12Gb SAS SAN Storage Array User Guide
- June 13, 2024
- Dell
Table of Contents
Dell PowerVault MD3400/3420/3800i/3820i/
3800f/3820f Storage Arrays
Getting Started Guide
Regulatory Model: E03J and E04J Series
Regulatory Type: E03J001 and E04J001
Notes, Cautions, and Warnings
NOTE: A NOTE indicates important information that helps you make better
use of your computer.
CAUTION: A CAUTION indicates either potential damage to hardware or loss
of data and tells you how to avoid the problem.
WARNING: A WARNING indicates a potential for property damage, personal
injury, or death.
Installation and Configuration
WARNING: Before performing the following procedure, review the safety
instructions that came with the system.
Unpacking A Rack System
Figure 1. Installing the System in a Rack
Unpack your system and identify each item.
Assemble the rails and install the system in the rack following the safety
instructions and the rack installation instructions provided with your system.
Connecting The Power Cable(s)
Figure 2. Connecting the Power Cable(s)
Connect the system’s power cable(s) to the system.
Securing The Power Cable(s)
Figure 3. Securing the Power Cable(s)
Open the cable retention bracket by pulling the tabs on its sides, insert the
cable, and secure the system power cable, as shown in the illustration.
Plug the other end of the power cable(s) into a grounded electrical outlet or
a separate power source such as an uninterruptible power supply (UPS) or a
power distribution unit (PDU).
Turning On The System
Figure 4. Turning on the System
Turn the power switch on the back of the system to the On position. The power LED will turn on.
Installing The Bezel
Figure 5. Installing the Bezel
Install the bezel as shown in the figure.
Dell Software License Agreement
Before using your system, read the Dell Software License Agreement that came
with your system. You must consider any media of Dell-installed software as
BACKUP copies of the software installed on your system’s hard drive. If you do
not accept the terms of the agreement, call the customer assistance telephone
number. For customers in the United States, call 800-WWW-DELL
(800-999-3355). For customers outside
the United States, see dell.com/support and
select your country or region from the top left of the page.
Other Information You May Need
WARNING: See the safety and regulatory information that shipped with your
system. Warranty information may be included within this document or as a
separate document.
- The Owner’s Manual provides information about system hardware features and describes how to troubleshoot the system and install or replace system components. This document is available online at dell.com/support/manuals.
- The Administrator’s Guide provides information about Modular Disk Storage Manager software features and describes how to configure and manage your modular disk system. This document is available online at dell.com/support/manuals.
- The Deployment Guide provides information about cabling your system and the installation and initial configuration of the Modular Disk Storage Manager software. This document is available online at dell.com/support/manuals.
- For videos and other resources on PowerVault MD series, see dell.com/PVresources.
- The rack documentation included with your rack solution describes how to install your system into a rack, if required.
- Any media that ships with your system that provides documentation and tools for configuring and managing your system, including those pertaining to the operating system, system management software, system updates, and system components that you purchased with your system.
NOTE: Always check for updates on
dell.com/support/manuals and read the
updates first because they often supersede information in other documents.
NOTE: When upgrading your system, it is recommended that you download and
install the systems management firmware on your system from
dell.com/support.
Obtaining Technical Assistance
If you do not understand a procedure in this guide or if the system does not
perform as expected, see your system Owner’s Manual. Dell offers comprehensive
hardware training and certification. See
dell.com/training for more information. This
service may not be offered in all locations.
Technical Specifications
NOTE: The following specifications are only those required by law to ship with your system. For a complete and current listing of the specifications for your system, go to dell.com/support.
Power
AC power supply (per power supply)
Wattage| 600 W
Heat dissipation (maximum)| 100 W
NOTE: Heat dissipation is calculated using the power supply wattage
rating. The heat dissipation values are for the entire system which includes
chassis and two controllers.
Voltage| 100–240 V AC (8.6 A–4.3 A)
NOTE: This system is also designed to be connected to IT power systems
with a phase to phase voltage not exceeding 230 V.
Battery| 6.6 V DC, 1100 mAh, 7.26 W Lithium Ion Battery
Physical
PowerVault MD3400/MD3800f/MD3800i
Height| 8.68 cm (3.41 inches)
Width| 44.63 cm (17.57 inches)
Depth| 60.20 cm (23.70 inches)
Weight (maximum configuration)| 29.30 kg (64.6 lb)
Weight (empty)| 8.84 kg (19.5 lb)
PowerVault MD3420/MD3820f/MD3820i
Height| 8.68 cm (3.41 inches)
Width| 44.63 cm (17.57 inches)
Physical
Depth| 54.90 cm (21.61 inches)
Weight (maximum configuration)| 24.22 kg (53.4 lb)
Weight (empty)| 8.61 kg (19 lb)
Environmental
NOTE: For additional information about environmental measurements for
specific system configurations, see
dell.com/environmental_datasheets.
Temperature
Maximum Temperature Gradient (Operating and Storage)| 20 °C/hour (36 °F/hour)
Storage Temperature Limits| -40 °C to 65 °C (-40 °F to 149 °F)
Temperature (Continuous Operation)
Temperature Ranges (for altitude less than 950 m or 3117 ft)| 10 °C to 35 °C
(50 °F to 95 °F) with no direct sunlight on the equipment
NOTE: For information on supported expanded operating temperature range
and configurations,
see the Owner’s Manual
dell.com/support/manuals.
Humidity Percentage Range| 10% to 80% Relative Humidity with 26 °C (78.8 °F)
maximum dew point.
Relative humidity
Storage| 5% to 95% RH with 33 °C (91 °F) maximum dew point. Atmosphere must be
non-condensing at all times
Maximum vibration
Operating| 0.26 Grms at 5 Hz to 350 Hz in operational orientation
Storage| 1.88 Grms at 10 Hz to 500 Hz for 15 minutes (all six sides tested)
Maximum shock
Operating| One shock pulse in the positive z axis (one pulse on each side of
the system) of 31 G for 2.6 m in the operational orientation.
Storage| Six consecutively executed shock pulses in the positive and negative
x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 m.
Altitude
Operating| –30.5 m to 3048 m (–50 to 10,000 ft).
NOTE: For altitudes above 2950 ft, the maximum operating temperature is
derated 1.8 ºF/1000 ft.
Storage| Up to 12,000 m ( 39,370 ft).
Operating Altitude De-rating| Up to 35 °C (95 °F) maximum temperature is
reduced by 1 °C/300 m (1 °F/547 ft) above 950 m (3,117 ft)
35 °C to 40 °C (95 °F to 104 °F) maximum temperature is reduced by 1 °C/175 m
(1 °F/319 ft) above 950 m
(3,117 ft)
40 °C to 45 °C (104 °F to 113 °F) maximum temperature is reduced by 1 °C/125 m
(1 °F/228 ft) above 950 m (3,117 ft)
Particulate Contamination
NOTE: This section defines the limits to help avoid IT equipment damage
and/or failure from particulates and gaseous contamination. If it is
determined that levels of particulates or gaseous pollution are beyond the
limits specified below and are the reason for the damage and/or failures to
your equipment it may be necessary for you to remediate the environmental
conditions that are causing the damage and/or failures. Remediation of
environmental conditions will be the responsibility of the customer.
Air Filtration
NOTE: Applies to data center environments only. Air filtration
requirements do not apply to equipment designed to be used outside a data
center, in environments such as an office or
factory floor.| Data center air filtration as defined by ISO Class 8 per ISO
14644-1 with a 95% upper confidence limit.
NOTE: Air entering the data center must have MERV11 or MERV13 filtration.
Conductive Dust
NOTE: Applies to data center and non-data center environments.| Air must
be free of conductive dust, zinc whiskers, or other conductive particles.
Corrosive Dust
NOTE: Applies to data center and non-data center environments.| • Air
must be free of corrosive dust.
• Residual dust present in the air must have a deliquescent point less than
60% relative humidity.
Gaseous Contamination
NOTE: Maximum corrosive contaminant levels measured at ≤50% relative
humidity
Copper Coupon Corrosion Rate| <300 Å/month per Class G1 as defined by
ANSI/ISA71.04-1985.
Silver Coupon Corrosion Rate| <200 Å/month as defined by AHSRAE TC9.9.
References
- Product Safety, EMC and Environmental Datasheets | Dell
- Support | Dell US
- Manual-Hub.com – Free PDF manuals!
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>