TESLA 047-1406 Smart Sensor Smoke User Manual
- June 9, 2024
- Tesla
Table of Contents
- TESLA 047-1406 Smart Sensor Smoke
- Packing List
- Product Description
- Indicator and Buzzer States
- Network Setting
- Installation Instructions
- Precautions
- Fire Alarm Function
- Mute Function
- Troubleshooting
- Technical Parameters
- INFORMATION ABOUT DISPOSAL AND RECYCLING
- EU DECLARATION OF CONFORMITY
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
TESLA 047-1406 Smart Sensor Smoke
Packing List
Please check if all accessories are included
Product Description
Please check if all accessories are included
Indicator and Buzzer States
- Red indicator flashes. | The buzzer beeps. |Alarm is triggered.
- Red indicator flashes once every 50 seconds. | The buzzer does not beep. | The product works properly.
- Yellow indicator flashes once every 40 seconds. | The buzzer beeps shortly. | Battery power is low.
- Red indicator flashes. | The buzzer beeps 4 times. | The product is in self-checking and alarm simulating state.
- Green indicator flashes quickly. | The buzzer does not beep. |
- The product is in network setting mode.Indicator and Buzzer States Red indicator flashes. | The buzzer beeps. |Alarm is triggered.
- Red indicator flashes once every 50 seconds. | The buzzer doe not beep. | The product works properly.
- Yellow indicator flashes once every 40 seconds. | The buzzer beeps shortly. | Battery power is low.
- Red indicator flashes. | The buzzer beeps 4 times. | The product is in self-checking and alarm simulating state.
- Green indicator flashes quickly. | The buzzer does not beep. |
- The product is in network setting mode.
Network Setting
- Power on the product
- Press the reset button for 5S and release, the green LED will flash for network setting.
Network setting note:
- Press the button for 5s-10s, the red LED is on, it will turn off after 5s. Then green LED is on. Release the reset button, the green LED flashes for network setting.
- The green LED will be on for 5s then turns off to indicate network setting succeeds, the product is in networking detecting status. If network setting fails in 60s, the yellow LED is on for 5s then turns off, the product is in standalone working status
Installation Instructions
1. Installation methods
- Using screws
- Using 3M sticker
- Installation checking
Check if the product is installed properly
If the semicircle on the product is aligned with the line on the mounting base to form an arrow, the product is installed improperly.
If the semicircles on the product and mounting base are aligned to form a circle, the product is installed properly
Precautions
-
Mount the product only on indoor ceilings.
-
Install the product at least 50 cm away from lighting products.
-
Do not install the product in bathrooms or other moist environments.
-
Do not install the product in places with non-fire smoke or steam.
-
Ensure that the temperature of the installation envi-ronment is within the range of-10°C to +55°C.
-
If a cupboard is near the ceiling, install the product at least 60 cm away from the cupboard.
-
Install the product at least 150 cm away from ventilators, air conditioners, and air vents.
-
You are advised to use screws to install the product.
If you use a 3M sticker to install it, any product damage or safety accidents incurred therefrom will be your responsibility. -
If you choose to use a 3M sticker, affix the product to a smooth, even, dry, and clean surface.
-
Regularly check whether the product is attached to the surface securely to prevent it from falling down.
-
The product cannot be mounted to the mounting base unless the battery is installed.
-
If you affix the product to a painted surface, peeling of the paint may cause the product to fall down. If this occurs, you are liable for any problems incurred therefrom.
Fire Alarm Function
-
When the product detects smoke, it immediately sends audible and visual alarm signals.
-
In case of fire, take proper measures immediately. For example, call the fire emergency number, or use a fire extinguisher to put out the fire.
-
If there is no fire, press the mute/self-diagnostic button to mute the product.
The product will be mute for 90s. During this period, the product will not generate any audible or visual alarm. After 90s, the product will be restored to the detection state. -
The product will generate a fire alarm when the following items contact it directly:
-
Mist sprayed from pesticides or cosmetics
-
Smoke generated by cigarettes and incense sticks
-
Smoke-type or thermal evaporation-type pesticides
-
Cooking smoke or steam
-
Condensation
Alarm and Test
-
Detection state: The status indicator blinks red at 50s intervals.
-
Self-checking state: When you press the mute/self-chec-king button, the status indicator will turn red. If you press and hold the mute/ self- diagnostic button for less than 5s, the product will enter the self-checking state, the status indicator will flash red, and the buzzer will beep (same as in alarm state).
-
When the smoke density reaches the preset alarm threshold, the product generates an alarm.
-
During self-checking test, keep away from the buzzer to avoid loud alarm sound from damaging your hearing.
-
If the product generate an alarm when it is monitoring, potential risks may exist. Do not ignore the alarm and try to locate the cause.
IMPORTANT
Ignoring the alarm could result in property damage, personal injury, or even
death. If the product fails a test, see „Troubleshooting“ to rectify the
fault. If the fault persists, replace the product immediately.
Mute Function
If the product generates an alarm, potential risks may exist. Before you mute
the product, ensure that there is no fire. Do not block the product or disable
it in any way. If you do so, the product can no longer provide you with
protection. If the product generates an alarm because it detects smoke in the
kitchen but not a fire (for example, bacon frying), pre-ss the mute/self-
diagnostic button on the panel to mute the product. When the product is muted,
the status indicator will rapidly blink red. The product sensitivity will be
restored automatically within 90s.
Note: If the smoke density surrounding the product is still high, the product
will generate an alarm again. Open the door and window to let out the smoke.
If you do not know the cause for the alarm, try to locate the source of the
smoke, as ignoring the alarm could result in property damage, personal injury,
or even death.
Routine Maintenance
The product has a maintenance-free design. You only need to perform the
following routine operations to ensure that the product works properly.
- Suggest to test the product at least once every week. For details on how to test the product, see „Alarm and Test“.
- Keep the product clean and remove dust from it with a vacuum cleaner and soft brush at least once every year. v
Use a cotton cloth or sponge to clean the product. Do not use solvents or
detergents, which may enter the product and cause damage to the sensor or
circuit.
Note: Do not paint your product. The paint may block smoke intake vents
of the product, causing the product to malfunction.
Troubleshooting
If the product malfunctions, its battery may have reached its valid lifespan, or the product may be affected by dust, smo-ke residue, or other dirt. If this is the case, refer to „Routine Maintenance“ for instructions on cleaning the product. If the fault persists, perform the following operations:
- If the product does not respond, check whether the product is correctly mounted to the mounting base.
- If the product intermittently beeps (at about 40s intervals), the battery level is low. Replace the battery within one week.
- If you often encounter non-fire alarm, please try to relocate your smoke alarm.
- If the product generates alarms frequently when there is no fire or smoke, clean the product or reinstall the product in another position.
IMPORTANT
If the fault persists after you perform the preceding operations, contact the
local vendor. Do not disassemble the product yourself, or the warranty service
for the product will become invalid.
Technical Parameters
- Wireless Technology ZigBee
- Transmission Frequency 2.4 GHz
- Working Voltage DC 3 V CR123A battery
- Low power indication Supported
- Working Temperature -10°C to +55°C
- Detector Type Independent smoke detector
- Alarm Sound Pressure ≥ 80 dB (3 m in front of the smoke detector)
- Installation Position Ceiling
- Battery Lifespan More than 3 years (20 times/day)
- Dimensions 90 mm x 37 mm
INFORMATION ABOUT DISPOSAL AND RECYCLING
This product is marked with the symbol for separate collection.
The product must be disposed of in accordance with the regulations for
disposal of electrical and electronic equipment (Directive 2012/19/EU on waste
electrical and electronic equipment). Disposal together with regular municipal
waste is prohibited. Dispose of all electrical and electronic products in
accordance with all local an European regulations at the designated collection
points which hold the appropriate authorisation and certification I line with
the local and legislative regulations. Correct disposal and recycling help to
minimise impacts on the environment and human health. Further information
regarding disposal can be obtained from the vendor, authorised service centre
or local authorities.
EU DECLARATION OF CONFORMITY
Hereby, Tesla Global Limited declares that the radio equipment type TSL-SEN- SMOKE is in compliance with EU directives. The full text of the EU declaration of conformity is available at the following internet address: tsl.sh/doc
- Connectivity: Wi-Fi 2,4 GHz IEEE 802.11b/g/n
- Frequency band: 2.412 – 2.472 MHz
- Max. radio-frequency power (EIRP): < 20 dBm
Manufacturer
Tesla Global Limited
Far East Consortium Building,
121 Des Voeux Road Central
Hong Kong
www.teslasmart.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>