CONDTROL XP3 Pro Laser Distance Meter User Manual

June 9, 2024
CONDTROL

CONDTROL XP3 Green Laser Distance Meter

CONDTROL-XP3-Green-Laser-Distance-Meter-product-image

Congratulations on your purchase of laser distance meter XP3 GREEN CONDTROL. Safety instructions can be found in the end of this user manual and should be carefully read before you use the product for the first time.

INTENDED USE

Laser distance meter XP3 GREEN is intended to measure distance, to stake out a line, to calculate area and volume of measured objects as well as perform calculations by tilt sensor and Pythagoras’ Theorem and able to transmit measuring results via Bluetooth. The product is suitable for use at both indoor and outdoor building areas.

DELIVERY SET

The delivery set of XP3 GREEN includes:

  1. Laser distance meter – 1pc.
  2. Carry pouch with a strap – 1 pc.
  3. User manual – 1 pc.
  4. Batteries (type AAA) – 3 pcs.
  5. USB charger – 1 pc.

TECHNICAL SPECIFICATIONS

Working range* 0,05– 120 m*
Measuring accuracy ** ± 1,5 mm**
Smallest unit displayed 1 mm
Display backlight +
Reference point setting +
Continuous measurement (tracking) +
Max./min. value +
Addition/subtraction +
Area/wall area/volume +
Calculation of horizontal distance by tilt sensor +
Calculations by Pythagoras’ Theorem +
Stake-out function +
Timer +
Bluetooth +
--- ---
Internal memory +
Laser Class II, 635 nm, <1 mW
Working temperature –10 °С … +50 °С
Storage temperature –20 °С … +60 °С
Dust and water protection IP54
Dimensions 136х59х28 mm
Weight 170 g
Power supply 3 х battery AAA 800 mAh 1.2V Ni-MH

PRODUCT DESCRIPTION

  1. Display
  2. Keyboard
  3.  Switch on the device / turn on laser beam / single distance measurement / continuous measurement
  4. Addition/up/increase the value/ flip through measuring results in memory (forward)
  5. Subtraction/down/decrease the value/ flip through measuring results in memory (backwards)
  6. Timer/measuring unit
  7. Calculation of area/wall area/volume/ point-to-point measurement
  8. Calculations by tilt sensor and Pythagoras’ Theorem /stake-out
  9. Bluetooth/reference point
  10. Memory/switch on/off the sound signal
  11. Switch off the device /clear / exit mode
  12. Strap location
  13. End-piece
  14. Mini-USB connector for charging

Display

  1. Main line
  2. Additional lines
  3. Indication of tilt angle
  4. Indication of the mode
  5. Indication of battery charge level
  6. Measuring unit
  7. Reference point

OPERATION

Insert/replace batteries
Insert batteries observing correct polarity. Use nickel-metal-hydride batteries.
Charge level is shown on display. Charge batteries when symbol on the display. Use USB charger delivered in the set only. Don’t use the product while charging.
It takes approximately 4 hours to fully charge the batteries.

Switch on/off

Switch on: press .
Switch off: press and hold for 1 sec.

Measuring unit
To select the appropriate measuring unit press and hold for 2 sec. required number of times.

Sound signal
To switch on/off sound signal press and hold for 2 sec.

Reference point

Press and hold for 1 sec.| Select reference point.

Corresponding symbol will appear on the display

---|---
****| Front
Tripod
RearEnd-piece

Single distance measurement

Press Switch on the device.
Press Switch on the laser beam. Aim the product at the object of measurement.
Press M– measuring result
Press Delete the last measuring result.

Continuous measurement (tracking)

Press and hold for 1 sec.| Activate continuous measurement (tracking) function. Laser beam is switched on simultaneously.
---|---
****|

  • tilt angle value
  • maximal value
  • minimal value
  • current value

Press Stop continuous measurement.

The last measured values are shown on the display.

Stake out

Press and hold for 2 sec.| Activate stake out function. Symbol  appears on the display.
---|---
Press    and |
Set the value of distance А*.
Press| Confirm the value of distance A.
Press  |
Set the value of distance В*.
Press| Confirm the value of distance B. Start taking measurements. Laser beam is flashing. Move the product slowly along the stake-out line. Arrows   and on the display indicate in what direction it is required to move the product in order to reach stake-out point.
| If sound signal is on, when approaching the stake- out point the product emits sound signal. When reaching the stake-out point symbol   appears on the display and sound signal tonality is changed.
---|---
****|

  • distance between the object and stake-out point of last measured distance. This value will increase after each next measurement by the value of last taken measurement.
  • value of distance A
  • value of distance В
  • current distance to the next stake-out point.

Mark point А and go on moving the product along stake-out line until you reach point B. If it is necessary to transfer several equal distances, repeat the last operation required number of times.

Press| Stop the measurement

  • If press and hold the speed is increased.
Press Switch on the laser beam. Aim the product at the object of measurement.
Press First measurement. Measuring result appears in the main line.
Press Activate addition  subtraction .
Press Switch on the laser beam. First measuring result moves to the line 2 on

the display.
Press


|

  • Second measurement.
  • first measurement
  • second measurement
  • result of addition/subtraction of 2 measurements

---|---
To do addition/subtraction of more than 2 measurements press  and perform the above mentioned operations required number of times.
Press| Exit the mode.

CALCULATIONS  Area

Press| Activate function of area calculation. Symbol appears on the display. Laser beam is on.
---|---
Press| First measurement (length).
Press| Second measurement (width).
****|

  • length
  • width
  • area

Wall area

Press 2 times| Activate function of wall area calculation. Symbol  appears on the display. Laser beam is on.
---|---
Press| First measurement (height).
Press| Second measurement (length 1).
Press| Third measurement (length 2).
****|

  • height
  • length 1
  • length 2
  • wall area

Press| 3rd, 4th, 5th etc. measurements can be done unlimited number of times. Each new wall surface is added to previously calculated wall area result.

Volume

Press 3 times| Activate function of volume calculation. Symbol  appears on the display. Laser beam is on.
---|---
Press| First measurement (length).
Press| Second measurement (width).
Press| Third measurement (height).
---|---
****|

  • length
  • width
  • height
  • volume

Point-to-point measurement

**** Long press for 1 sec.| Symbol     appears on the display.

Laser beam is on. Line       is flashing.

---|---
Press| First measurement (distance to point 1)
Press| Second measurement (distance to point 2)
|

  • distance to point 1 (measured)
  • distance to point 2 (measured)
  • distance between points 1 and 2 (calculated)

**Note:** Make sure that the starting point of the measurement (for example, the bottom end of the device) is the same in both measurements.

Calculation of horizontal distance by tilt sensor

Press| Activate function of horizontal distance calculation by tilt sensor. Laser beam is on. Symbol  appears on the display. 1 line – current tilt angle value.
---|---
Press| First measurement (hypotenuse).
Press

|

  • hypotenuse(measured)
  • tilt angle (measured)
  • vertical distance (calculated)
  • vertical distance (calculated)

Calculation of distance by 2 additional measurements (Pythagoras’ Theorem)

Press 2 times Symbol appears on the display.
Press First measurement (hypotenuse).
Press Second measurement (cathetus).
****
  • hypote nuse (measured)
  • cathetus (measured)
  • cathet us (calculated)

Calculation of distance by 3 additional measurements (Subtraction of 2 cathetuses)

Press   3 times Symbol appears on the display.
Press **** First measurement (hypotenuse 1).
Press **** Second measurement (hypotenuse 2).
Press Third measurement (cathetus).
****
  • hypotenuse 1 (measured)
  • hypotenuse 2 (measured)
  • cathetus (measured)
  • cathetus (calculated)

Calculation of distance by 3 additional measurements (Sum of cathetuses)

Press   4 times Symbol appears on the display.
Press First measurement (hypotenuse 1).
Press Second measurement (cathetus).
Press Third measurement (hypotenuse 2).
****
  • hypotenuse 1 (measured)
  • cathetus (measured)
  • hypotenuse 2 (measured)
  • cathetus (calculated)

Timer

Press Activate timer. Default value is 5 seconds.
Press    Adjust the timer response time.
Press Start timer.

Memory

Press| Enter memory. A number of saved measuring results is reflected on symbol   on the display.
---|---
Press      | Flip through saved measuring results.

Bluetooth

Press| Activate Bluetooth function. Symbol  appears on the display. Switch on Bluetooth in your phone, tablet PC or laptop. For further operation please use application Smart Measure CONDTROL.
---|---

MESSAGE CODES
While operation, the following codes/symbols may appear on the display:

Message Cause Solution

ERR

|

Out of measuring range

|

Use the device within the range.

ERR 1

|

Laser signal is too weak

|

Use the reflecting plate.

ERR 2| Laser signal is too strong| Use the reflecting plate.
ERR 3| Low battery voltage.| Сharge or replace the batteries.

ERR 4

| The ambient temperature is out of the working range.| Use the device in the specified temperature.

ERR 5

| Measuring error in Pythagoras function.| Measure again and ensure that hypotenuse is bigger than cathetus.
ERR 6| Failure of tilt sensor.| Please contact service center.

SAFETY REGULATIONS

The user manual should be read carefully before you use the product for the first time. Unintended use of the product can be dangerous for human’s health and cause serious injury. Keep this user manual. If the product is given to somebody for temporary use, be sure to enclose user manual to it.

  • Do not misuse the product
  • Do not remove warning signs and protect them from abrasion, because they contain information about safe operation of the product.

The device belongs to laser product class 2 in accordance with EN60825-1:

  • Do not look into the laser beam or its reflection, with unprotected eye or through an optical instrument. Do not point the laser beam at people or animals without the need. You can dazzle them.
  • To protect your eyes close them or look aside.
  • It is prohibited to disassemble or repair the product yourself. Entrust product repair to qualified personnel and use original spare parts only.
  • Do not use the product in explosive environment, close to flammable materials.
  • Avoid heating the batteries to avoid the risk of explosion and electrolyte leakage. In case of liquid contact with skin, wash it immediately with soap and water. In case of contact with eyes, flush with clean water during 10 minutes and consult the doctor.

CARE AND MAINTENANCE

Attention! The instrument is a precise device and requires careful handling. The following recommendations will extend the life of the product:

  • Do not point the product at the sun
  • Protect the product from bumps, falls, and excessive vibration; do not let liquids, construction dust and foreign objects get inside the product.
  • Do not expose the product to extreme temperatures.
  • If liquids get inside the product first remove the batteries, then contact a service center.
  • Do not store or use the product under high humidity conditions for a long time.
  • Clean the product with soft wet cloth.
  • Keep device optics clean and protect it from mechanical damage.
  • Сarry out control measurements occasionally, especially if the product is subject to excessive mechanical or other impact, before and after taking important measurements.

UTILIZATION
Expired tools, accessories and package should be passed for waste recycle. Please send the product to the following address for proper recycle:

  • CONDTROL GmbH
  • Wasserburger Strasse 9
  • 84427 Sankt Wolfgang

Germany
Do not throw the product in municipal waste!
According to European directive 2002/96/ЕC expired measuring tools and their components must be collected separately and submitted to environmentally friendly recycle of wastes.

WARRANTY

All CONDTROL GmbH products go through post-production control and are governed by the following warranty terms. The buyer’s right to claim about defects and general provisions of the current legislation do not expire.

  • CONDTROL GmbH agrees to eliminate all defects in the product, discovered during the warranty period, that represent the defect in material or workmanship in full volume and at its own expense.
  • The warranty period is 36 months and starts from the date of purchase by the end consumer (see the original supporting document).
  • The warranty doesn’t cover defects resulting from wear and tear or improper use, malfunction of the product caused by failure to observe the instructions of this user manual, untimely maintenance and service and insufficient care, the use of non-original accessories and spare parts. Modifications in design of the product relieve the seller from responsibility for warranty works. The warranty does not cover cosmetic damage, that doesn’t hinder normal operation of the product.
  • CONDTROL GmbH reserves the right to decide on replacement or repair of the device.
  • Other claims not mentioned above, are not covered by the warranty.
  • After holding warranty works by CONDTROL GmbH warranty period is not renewed or extended.
  • CONDTROL GmbH is not liable for loss of profit or inconvenience associated with a defect of the device, the rental cost of alternative equipment for the period of repair.

This warranty applies to German law except provision of the United Nations Convention on contracts for the international sale of goods (CISG).
In warranty case please return the product to retail seller or send it with defect description to the following address:
CONDTROL GmbH
Wasserburger Strasse 9
84427 Sankt Wolfgang
Germany

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals