RICE LAKE LaserLight3 ConnexLink Wireless Radio Installation Guide

June 9, 2024
RICE LAKE

RICE LAKE LaserLight3 ConnexLink Wireless Radio Installation Guide

ConnexLink™ Wireless Radio Installation

The ConnexLink Wireless Radio kit (PN 212753) allows communication from a LaserLight3 to a device with the matching radio (such as an indicator or remote display).
Manuals and additional resources are available from the Rice Lake Weighing Systems website at www.ricelake.com
Warranty information can be found on the website at www.ricelake.com/warranties
NOTE: For more information about LaserLight3, see LaserLight3 Large Display Indicator Technical Manual (PN 213589) orLaserLight3 Remote Display Technical Manual (PN 214748).
ConnexLink documentation and resources can be found at www.lairdconnect.com.
CAUTION: The LaserLight3 does not have a power switch. Before working with the unit, ensure the power cord is disconnected from the power outlet.

Parts Lis

Installation

IMPORTANT: Each ConnexLink radio is marked as Client or Server. Install the server type in indicators and the client type in remote displays.

LaserLight3 Type or Operating Mode| ConnexLink Type in LaserLight3| Paired ConnexLink
---|---|---
LaserLight3 Indicator| Server| Client
LaserLight3 Remote Display| Client| Server

  1. To attach adhesive feet to ConnexLink, align adhesive standoffs with ConnexLink mounting holes then secure with provided screws

  2. Disconnect LaserLight3 power cable from power outlet.

  3. Open the LaserLight3 enclosure.
    IMPORTANT: The ConnexLink power cable has a black (negative) wire and a black with white segments (positive) wire.
    Ensure power cables wires are connected to the power supply terminals with the same polarity.

  4. Attach the black negative power wire’s spade to the free -V0 terminal on LaserLight3 power supply.

  5. Attach the black and white positive power wire’s spade to the free +V0 terminal on LaserLight3 power supply

  6. Attach the power supply cable barrel connector to the ConnexLink 7-18VDC jack.

  7. Unscrew the antenna hole screw plug (bottom of enclosure) then collect the nut and washer (inside enclosure)

  8. Remove nut and tooth washer from antenna extension cable

  9. Inside enclosure, insert threaded end of antenna extension cable into antenna hole.

  10. Install washer and nut (previously removed) on threaded end of extension cable protruding from bottom of enclosure.

  11. Turn antenna clockwise onto the antenna extension cable until tight.

  12. Turn the free end of the antenna extension cable clockwise onto the antenna jack on ConnexLink until tight

  13. Attach transceiver 6-pin connector to RS-232 port (J3) on LaserLight3 CPU board.

  14. Attach the transceiver cable 9-pin connector to the ConnexLink I/O port and finger tighten retaining screws.

  15. Clean mount surface with Isopropyl Alcohol, and let dry.

  16. Peel protective backing off adhesive standoffs and position ConnexLink with power jack at top (vertically) in left side ofLaserLight3 enclosure.
    IMPORTANT: Ensure ConnexLink position will not obstruct enclosure door operation or make contact with circuit boards.

  17. . Apply firm pressure to adhesive pads for 30 seconds.

Serial Configuration

After hardware installation, LaserLight3 software must be configured to communicate from its RS-232 port with the ConnexLink.
In order to function correctly, the Baud and Bits parameters in the LaserLight3 require setup.
NOTE: By default LaserLight3 is configured with the required parameters to operate the ConnexLink. Ensure that the following settings are configured. If LaserLight3 default serial communication configuration has been altered, the system will not function. For more information about LaserLight3, see LaserLight3 Large-Display Weight Indicator Technical
Manual (PN 213589) or LaserLight3 Remote Display Technical Manual (PN 214748).

  1. Enable Setup mode by either pressing the key (if a shunt is installed on J24 pins two and three) or opening the LaserLight3 and shorting J25 pins momentarily.
    NOTE: Enabling Setup mode grants access to various LaserLight3 menus that are restricted in normal operation, including the Setup menu

  2. Perform one of the following:
    • For LaserLight3 Remote Display, navigate to Setup ▼Comm ▼Serial ▼ RS232 1/2 ▼ Trigger ► Baud
    • For LaserLight3 Large-Display Weight Indicator, navigate to Audit ► Setup ▼Comm ▼Serial ▼ RS232 1/2 ▼ Trigger ► Baud

Specs

This kit features a ConnexLink communication module. Visit www.lairdconnect.comto view the latest list of technical specifications on the communication module.

Frequency Band

  • 902-928 MHz

Modulation

  • FHSS FSK

Interface

  • Standard: RS-232 (DB9 Male)
  • ConnexLink Pro: RS-485 (6-Pin Terminal Block)

Serial Interface Data Rate

  • Up to 115-200 kbps

Output Power

  • 5 mW-1000 mW variable

Input Power

  • 7-18 VDC

Current Draw (at 12 VDC)

  • 400 mA TXD, 40 mA RXD

Channels

  • 32 selectable channels

Security

  • 1-byte system ID, DES

Sensitivity

  • -99dB at full RF data rate

Range (line-of-sight):

  • Up to 20 miles (32 km)

Temperature:

  • -40°F to 176°F (-40ºC to 80°C)

Humidity (non-condensing):

  • 10% to 90%

Weight:

  • <6 oz (<170 g)

Dimensions:

  • 75 x 2.75 x 1.17 in (121 x 70 x 30 mm)

Antenna Connector:

  • Reverse polarity SMA jack (female)

Read More About This Manual & Download PDF:

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

RICE LAKE User Manuals

Related Manuals