Z-Wave TZ06 Wall Dual Relay Switch Module User Manual
- June 10, 2024
- Z-Wave
Table of Contents
Z-Wave TZ06 Wall Dual Relay Switch Module
TZ06 In Wall Dual relay(1 way) switch module
This in-wall switch module is a transceiver which is a Z-WaveTM enabled device
and is fully compatible with any Z-WaveTM enabled network. Mini size design
let the module can easily hide itself into the wall box and that will be good
for the house decoration.
There are many kind of application by using the module to switch Load On and
Off , one main application is the light control. If connect the com port
directly to AC Line terminal ,the new smart relay calibration technology can
reduce the inrush current caused by the load and let the module work perfectly
with many kind of light like incandescent, fluorescent and LED light. This
module can also connect to alternative power supply like DC 12V to switch
on/off 12V MR-16 light as follow picture.
Adding to Z-Wave™ Network
In the front casing, there is an on/off button with LED indicator below which
is used to toggle switch on and off or carries out inclusion, exclusion, reset
or association.
When first power is applied, its LED flashes on and off alternately and
repeatedly at 2-second intervals. It implies that it has not been assigned a
node ID and cannot work with Z-Wave enabled devices.
Auto Inclusion
The function of auto inclusion will be executed as long as the in wall switch
does not have Node ID and just connect the switch to main power.
Note : Auto inclusion timeout is 4 minute during which the node
information of explorer frame will be emitted once every 5 seconds. Unlike
“inclusion” function as shown in the table below, the execution of auto
inclusion is free from pressing the On/Off button on the Switch.
The table below lists an operation summary of basic Z-Wave functions. Please
refer to the instructions for your Z-WaveTM Certificated Primary Controller to
access the Setup function, and to include/exclude/associate devices
Function | Description | LED Indication |
---|---|---|
No node ID | The Z-Wave Controller does not allocate a node ID to the Switch. |
2-second on, 2-second off
Inclusion| Have Z-Wave Controller entered
inclusion mode.
| One press one flash
Pressing Include button of TZ06 three times within 1.5 seconds will enter
inclusion mode.
Exclusion| Have Z-Wave Controller entered exclusion mode.| One press one flash
Pressing Include button of TZ06 three times within 1.5 seconds will enter
exclusion mode.|
Node ID has been excluded.| 2-second on, 2-second off
Reset| Pressing Include button of TZ06 three times within 1.5 seconds will
enter inclusion mode.| One press one flash
Within 1 second, press Include button of TZ06 again for 5 seconds until LED is
off.
IDs are excluded.| 2-second on, 2-second off
Association| Have Z-Wave Controller entered association mode.
Or
Pressing Include button of TZ06
three times within 1.5 seconds will enter association mode| One press one
flash
There are 3 groups for the switch|
Including a node ID allocated by Z-Wave Controller means inclusion. Excluding
a node ID allocated by Z-Wave Controller means exclusion.
Failed or success in including/excluding the node ID can be viewed from the
Z-Wave Controller.
Sometimes people are not easy to execute exclusion or inclusion especially when TZ06 already installed in a wall box. To solve this issue, TZ06 support a special feature that can use S1 or S2 to execute “exclusion, inclusion, Reset or Association” at the first 3 minutes when first time connect to main power.
LED Indication
State Type | LED Indication |
---|---|
Normal | Whenever we switch On and off of the TZ06 by S1 S2 or On/Off button or |
RF command , the LED will lights up 1 second and then off.
No node ID| Under normal operation, when the Switch has not been allocated a
node ID, the LED flashes on and off alternately at 2-second intervals. By
pressing S1 S2 or On/Off button, it will stop flashing temporarily. However,
after disconnect and reconnect the Switch, the LED will flash on and off
alternately at 2-second intervals.
Choosing a Suitable Location
- Do not locate the Switch facing direct sunlight, humid or dusty place.
- The suitable ambient temperature for the Switch is 0°C~40°C.
- Do not locate the Switch where exists combustible substances or any source of heat, e.g. fires, radiators, boiler etc.
- After putting it into use, the body of Switch will become a little bit hot of which phenomenon is normal.
Installation
- Put the in wall switch into a wall box and connect the AC power wire L,N to TZ06 connector L, N.
- Connect the wall switch to the TZ06 as Fig1 .
- There are 3 mode TZ06 can be configured to match different kind of wall switch, please refer to 3-2 Edge / Pulse / Edge-Toggle mode which described in next section of this user manual
- If Edge-Toggle mode has been set, and the S1 S2 is connect to normal bi-stable switch, every time when change the state of the wall switch will also swap the state of Relay1 or Relay2
Programming
Basic Command Class / Binary Switch Command Class
The Switch will respond to BASIC and BINARY commands that are part of the Z-Wave system.
BASIC_GET / BINARY_SWITCH_GET
Since the switch have two relay, the Switch will report its On/Off state to
the
Controller by setting Configuration parameter 1.
Configuration parameter 1=1(default) Report ON either relay 1 ON or relay 2
ON
Report OFF when both relay 1 and relay 2 OFF
Configuration parameter 1=2 Report ON when relay 1 ON
Report OFF when relay 1 OFF
Configuration parameter 1=3 Report ON when relay 2 ON
Report OFF when relay 2 OFF
Basic Get Command: [Command Class Basic, Basic Get]
Basic Report Command:
Report OFF : [Command Class Basic, Basic Report, Value = 0(0x00)]
Report ON :[Command Class Basic, Basic Report, Value = (255)0xFF]
Binary Switch Get Command:[Command Class Switch Binary, Switch Binary Get]
Binary Switch Report Command :
Report OFF :[Command Class Switch Binary, Switch Binary Report, Value
=0(0x00)] Report ON :[Command Class Switch Binary, Switch Binary Report,
Value = (255)0xFF]
BASIC_SET / SWITCH_BINARY_SET
Since the switch have two relay, the load attached to the Switch will turn on
or
off upon receipt of the following commands from a Z-Wave Controller by setting
Configuration parameter 1.
Configuration parameter 1=1(default) switch ON and OFF both relay 1 and
relay 2
Configuration parameter 1=2 switch ON and OFF of relay 1
Configuration parameter 1=3 switch ON and OFF of relay 2
[Command Class Basic, Basic Set, Value = (255)0xFF] : the load attached
to the Switch turns on.
[Command Class Basic, Basic Set, Value = 0(0x00)] : the load attached to
the Switch turns off.
[Command Class Switch Binary, Switch Binary Set, Value = (255)0xFF] : the
load attached to the Switch turns on.
[Command Class Switch Binary, Switch Binary Set, Value = 0(0x00)] : the
load attached to the Switch turns off.
Z-Wave’s Groups (Association Command Class Version 1)
The Switch can be set to send reports to control associated Z-Wave devices. It
supports 3 association groups which every group has one node support.
Group1~Group3 support SWITCH_BINARY_REPORT.
For group 1, the Switch will report ON/OFF status of Relay1 and Relay2
For group 2, the Switch will report ON/OFF status of Relay1
For group 3, the Switch will report ON/OFF status of Relay2
Auto report to Grouping 1 ~3(Maximum Node 1)
On/Off Event Report
When “on” or “off ” state has been changed (ex. Press S1 S2 or include on/off
button), it will send Binary Switch Report to the nodes of Group1~3.
Binary Switch Report
ON :[Command Class Switch Binary, Switch Binary Report, Value =(255)0xFF] OFF :[Command Class Switch Binary, Switch Binary Report, Value =0(0x00)]
Multi Channel Command Class Version 3
TZ06 also support muti channel command class(version 3) , which include BINARY_SWITCH_GET, BINARY_SWITCH_SET You may control or get report from 3 endpoint of TZ06
BINARY_SWITCH_GET ,
You may get the ON/OFF state from every endpoint, when endpoint set to 1 ,
TZ06 will reply ON(0xFF) either Relay 1 or Relay2 is ON, report OFF (0x00)
when both Relay 1 and Relay2 OFF . If endpoint set to 2 , TZ06 will reply
state of Relay1 . If endpoint set to 3 and TZ06 will reply state of Relay2
Below is a example show a source endpoint 5 send a get command to TZ06
endpoint 1
COMMAND_CLASS_MULTI_CHANNEL|
---|---
MULTI_CHANNEL_CMD_ENCAP|
Source End Point = 0x05| (this is the endpoint of command owner here we assume
endpoint is 5,if the owner doesn’t support multi Channel this value will be 0)
(Bit Address + Destination End Point = 0x01)| (Bit Address =0;Destination End
Point range from 1~3)
Command Class = 0x25| (Command_Class_Switch_Binary = 0x25)
Command =0x02| (Switch_Binary_Get = 0x02)
Below is the example show TZ06 report to last command
COMMAND_CLASS_MULTI_CHANNEL|
---|---
MULTI_CHANNEL_CMD_ENCAP|
Source End Point = 0x01| Since the endpoint is 1 so TZ06 will reply ON(0xFF)
either Relay 1 or Relay2 is ON, report OFF (0x00) when both
Relay 1 and Relay2 OFF
(Bit Address + Destination End Point = 0x05)| (Bit Address =0;Destination End
Point)
Command Class = 0x25| (Command_Class_Switch_Binary = 0x25)
Command =0x03| (Switch_Binary_Report = 0x03)
Parameter 1 = 0xFF| (ON=0xFF , OFF=0x00)
BINARY_SWITCH_SET
By using BINARY_SWITCH_SET Command of Multi Channel Command Class
Encapsulation Command, you can switch both Relay1 and Relay2 ON/OFF by setting
endpoint to 1 or switch Relay1 ON/OFF by setting endpoint to 2 or switch
Relay2 ON/OFF by setting endpoint to 3
The example of the command show that switch off relay1 of TZ06
COMMAND_CLASS_MULTI_CHANNEL|
---|---
MULTI_CHANNEL_CMD_ENCAP|
Source End Point = 0x01| (this is the endpoint of command owner here we assume
endpoint is 1,if the owner doesn’t support multi Channel this value will be 0)
(Bit Address+Destination End Point = 0x02)| (Bit Address =0;Destination End
Point range1~3)
Command Class = 0x25| (Command_Class_Switch_Binary = 0x25)
Command =0x01| (Switch_Binary_Set = 0x01)
Parameter 1 = 0x00| (ON=0xFF , OFF=0x00)
Z-Wave’s Configuration
Configuration Parameter| Function| Size
(Byte)
| Value| Unit| Default| Description
---|---|---|---|---|---|---
1| Slected End Point| 1| 1-3| | 1| 1:Relay1 &
Relay2
| | | | | 2:Relay1
| | | | | 3:Relay2
2| Edge or Pulse mode or Edge-Toggle mode| 1| 1-3| | 1|
- Edge mode
- Pulse mode
- Edge-Toggle
Selected Endpoint
If Controller not using Multi_Channel command class to access the endpoint of
TZ06, you may configure the endpoint value to react the Basic Command Class or
Binary Switch Command Class.
Selected Endpoint 1: Default Selected Endpoint is 1
Set command| Relay state|
---|---|---
Basic Set or Binary_Switch_Set ON| Relay1 ON
& Relay2 ON|
Basic Set or Binary_Switch_Set OFF| Relay1 OFF
&
Relay2 OFF|
Get command| Relay state| Report to command sender
Basic_Get or Binary_Switch_Get| Relay1 ON
or
Relay2 ON| ON
Basic_Get or Binary_Switch_Get| Relay1 OFF
&
Relay2 OFF| OFF
elected Endpoint 2
Similar like Selected Endpoint 1 but only relate to Relay1 and ignore Relay2
Selected Endpoint 3
Similar like Selected Endpoint 1 but only relate to Relay2 and ignore Relay1
Edge / Pulse / Edge-Toggle mode
Manual switch S1 and S2 can set to Edge mode or Pulse mode or Edge-Toggle mode
, default value is Edge mode.
Edge mode: this mode is suitable for the bi stable wall switch that has
indicator point on the switch, and the same position correspond to same state
of relay1 and relay2 .
if the TZ06 relay change the state because of receiving Z-Wave RF command, it
may need two times of change (switch on to off or switch off to on) to let
relay back to the correspond state.
Pulse mode: this mode is suitable for the toggle type wall switch to swap the
state of
Relay1 or Relay2
Edge-Toggle mode: this mode is suitable for the normal bi-stable switch, every
time when change the state of the wall switch will also swap the state of
Relay1 or Relay2
Command Classes
The Switch supports Command Classes including…
- COMMAND_CLASS_SWITCH_BINARY
- COMMAND_CLASS_BASIC
- COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
- COMMAND_CLASS_VERSION
- COMMAND_CLASS_SWITCH_ALL
- COMMAND_CLASS_ASSOCIATION_V1
- COMMAND_CLASS_CONFIGURATION
- COMMAND_CLASS_MULTI_CHANNEL_V3
- COMMAND_CLASS_ALARM
Troubleshooting
Symptom | Cause of Failure | Recommendation |
---|---|---|
The Switch not working and LED off |
- The Switch is not connect to the Main power
- The Switch break down
|
- Check power connections
- Don’t open up the Switch and send it for repair.
The Switch LED illuminating, but cannot control the ON/OFF Switch of the load
attached| Check if the load connect into the Switch has its own ON/OFF switch|
Set the ON/OFF switch of the load attached to ON
The Switch LED illuminating, but the Detector cannot control the Switch|
- Not carry out association
- Same frequency interference
|
- Carry out association
- Wait for a while to re-try
LED keep flashing continuously, but cannot control| Overload occurs| Remove the load attached or check max. load cannot exceed 1500W~1650W
Specification
Operating Voltage| 100 ~240VAC
24-60V DC ±10%
---|---
Maximum Load| 1500W X2 (220V) 800W X 2 (120V)
Range| Minimum 30 m in door 100m outdoor line of sight
Operating Temperature| 0°C ~ 40°C
Frequency Range| TZ06 868.42 (EU) / TZ06 908.42(USA/Canada) / TZ06
922.5/923.9/926.3MHz (Taiwan/JP)MHz