RICE LAKE LaserLight 3 Remote Display User Guide

June 9, 2024
RICE LAKE

LaserLight 3 Remote Display
User Guide

This document describes how to set up the LaserLight3 to operate as a remote display.
Manuals and additional resources are available from the Rice Lake Weighing Systems website at www.ricelake.com
Warranty information can be found on the website at www.ricelake.com/warranties
NOTE: For more information about LaserLight3, see LaserLight3 Remote Display Technical Manual (PN 214748).

Preliminary Tasks

  • Unpack and visually inspect the LaserLight3 for damage. If parts were damaged in shipment, notify Rice Lake Weighing Systems and the shipper immediately.
  • Mount LaserLight3 with included mounting bracket.

Cable Connection

Connect data communication from an indicator to the CPU board..
NOTE: If using factory installed Wi-Fi communication, see addendum PN 214366 for configuration.
WARNING: The LaserLight3 has no on/off switch. Before opening the unit, ensure the power cord is disconnected from the power outlet.
Use a ground wrist strap to protect components from electrostatic discharge (ESD) when working inside the enclosure.

  1. Unplug LaserLight3 from power source.
  2. Loosen captive thumbscrews then open enclosure front door.
  3. Route communication cable from indicator through LaserLight3 cord grip into the enclosure.
  4. Connect cable to one of the following communication ports RS-232 (J3), RS-482/422 (J4), Ethernet (J8) or 20 mA (J11), while adhering to port pin assignment (Figure 1). Coordinate software settings with the installed wiring.

NOTE: The LaserLight3 parts kit includes four, five and six pin connectors to facilitate connection with the CPU board ports.RICE LAKE
LaserLight 3 Remote Display - fig

Software Configuration

Access Setup Mode
Press Menu to access the setup menu in setup mode and configure the LaserLight 3. If Setup mode is inaccessible by pressing the Menu Button, perform the following:

  1. Plug in LaserLight3 and allow to power on and initialize.

  2. Open front door using captive thumbscrews.

  3. Perform one of the following to enter Setup mode:
    • Short setup jumper pins (J25) on CPU board
    • Install shunt on audit jumper (J24) pins 2 and 3 on CPU board (enables Audit Trail mode and allows Setup access from Menu) and then press the Menu button

  4. Close front door and secure with captive thumbscrews.

RICE LAKE LaserLight 3 Remote Display - fig 1

CPU Board Jumper Function Application
J24 Audit Trail Off Install shunt on pins 1 and 2
Audit Trail On Install shunt on pins 2 and 3
J25 Setup Short pins 1 and 2 momentarily

Configure Display Type
The Type parameter in the Dsplay (Display) menu has three options to set the information that appears on the display. Set the Type parameter as:

  • Legacy (annunciators along the bottom)
  •  Standard (annunciators along the right side)RICE LAKE LaserLight 3 Remote Display - fig 2

Automatic Baud Configuration

The Auto (Automatic) baud configuration cycles through serial communication protocol (RS-232, RS-485/422 and 20 mA) baud settings (baud rate, bits and stop bits) until it establishes a serial connection.
Set the Auto setting for the Baud parameter of the communication protocol used.RICE LAKE LaserLight 3 Remote Display - fig 3

Auto-Learn and Data String Recognition
Auto-Learn examines the data stream sent from the connected indicator and determines the data settings and format used by the indicator. Auto-Learn is capable of  recognizing several common data string formats used in the weighing industry. If enabled, LaserLight3 attempts to learn the incoming data steam when it is powered on,  when the data stream starts or when the data stream is paused and restarted.
Set the used communication protocol (RS-232, RS-485/422, 20 mA, Ethernet or Wi-Fi) Trigger parameter as RmtIn (Remote In) to enable Auto-Learn.
NOTE: It is suggested to only configure one communication protocol as Remote In. If more than one communication protocol is configured as Remote In, LaserLight3 uses  the first configured communication protocol that occurs in the system menu. For example, if RS232-2 and 20mA were set as Remote In, RS232-2 would be used as it  occurs before 20MA in the system menu.RICE LAKE
LaserLight 3 Remote Display - fig 4

NOTE: If the text NODATA appears, verify connection from the indicator to LaserLight3.
If data does not display, ensure data stream is set to transmit from indicator.
Auto-Learn mode may be bypassed by using Manual mode.
If OvrRng (Over Range) displays after the Auto-Learn process parses data, then the weighment value sent is beyond the capabilities of the display (six characters). Manual  mode can frequently resolve character quantity issues.
If the LaserLight3 does not match a data format, it automatically attempts to parse the weight, units, mode, status and weight data out of frame. If a valid weight is not found,  manual mode must be used to configure LaserLight3.
For more information about Manual mode see LaserLight3 Remote Display Technical Manual (PN 214748).

© Rice Lake Weighing Systems Specifications subject to change without notice.
230 W. Coleman St. • Rice Lake, WI 54868 • USA
U.S.800-472-6703 • Canada/Mexico 800-321-6703 • International 715-234-9171 • Europe +31 (0)26 472 1319
September 30, 2022
www.ricelake.com
PN 215476 Rev A

Documents / Resources

| RICE LAKE LaserLight 3 Remote Display [pdf] User Guide
LaserLight 3 Remote Display, LaserLight 3, Remote Display, Display
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

RICE LAKE User Manuals

Related Manuals