Telemecanique XUM4ANXBM8 Photo Electric Sensors Instruction Manual

June 9, 2024
Telemecanique

XUM4ANXBM8 Photo Electric SensorsTelemecanique XUM4ANXBM8 Photo
Electric Sensors Instruction Manual

NPN – M8 Connector : PNP – M8 Connector :
XUM4ANXBM8 XUM4APXBM8
XUM5ANXBM8 XUM5APXBM8
XUM6ANXBM8 XUM6APXBM8
NPN – 2 m Cable : PNP – 2 m Cable :
XUM4ANXBL2 XUM4APXBL2
XUM5ANXBL2 XUM5APXBL2
XUM6ANXBL2 XUM6APXBL2
Model Sensing distance D
XUM4A 0,25 m / 0.82 ft
XUM5A 1,9 m / 6.23 ft
XUM6A 1,1 m / 3.61 ft

Telemecanique XUM4ANXBM8 Photo Electric Sensors - fig
1

DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH

  • Disconnect all power before servicing equipment.
  • Do not connect this device to AC power.
  • The power voltage must not exceed the rated range.

Failure to follow these instructions will result in death or serious injury.

WARNING
IMPROPER SETUP OR INSTALLATION

  • This equipment must only be installed and serviced by qualified personnel.
  • Read, understand, and follow the compliance below, before installing the XUM Photo-electric sensor.
  • Do not tamper with or make alterations on the unit.
  • Comply with the wiring and mounting instructions.
  • Check the connections and fastening during maintenance operations.
  • The proper functioning of the XUM photoelectric sensor and its operating line must be checked regularly and according to the application (for example number of  operations, level of environmental pollution, etc.).

Failure to follow these instructions can result in death, serious injury, or equipment damage.

Mounting and tightening torques

Telemecanique XUM4ANXBM8 Photo Electric
Sensors - fig 3

CAUTION
UNINTENDED EQUIPMENT OPERATION
Do not apply excessive impact on the sensor during the installation process, so as to prevent damage or deterioration in the degree of protection.
Failure to follow these instructions can result in injury or equipment damage.

LEDs and settings

Telemecanique XUM4ANXBM8 Photo Electric Sensors - fig
4

Wiring diagrams

Telemecanique XUM4ANXBM8 Photo Electric Sensors - fig
5

Electrical equipment should be installed, operated and maintained only by qualified personnel.
No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material.
© 2021 Schneider Electric. “All Rights Reserved.”

Wiring precaution

Telemecanique XUM4ANXBM8 Photo Electric Sensors - fig
6

NOTICE
UNINTENDED EQUIPMENT OPERATION
Do not pull on the sensor cable so as to prevent damage or deterioration in the degree of protection
Failure to follow these instructions can result in equipment damage.

Dimensions

Telemecanique XUM4ANXBM8 Photo Electric Sensors - fig
7

Accessories

Telemecanique XUM4ANXBM8 Photo Electric Sensors - fig
8

Pre-wired connectors (examples)
PVC cable for general use
PUR cable for severe industrial environments

M8, 4 pins
Cable length| | | M8 – M12, 4 pins| |
---|---|---|---|---|---
PVC| PUR| PVC| PUR| Jumper length| PUR| PUR
2 m / 6.56 ft.| XZCPV0941L2| XZCP0941L2| XZCPV1041L2| XZCP1041L2| 1 m / 3.28 ft.| XZCR1509041J 1| XZ CR1510041J1
5 m / 16.4 ft.| XZCPV0941L5| XZCP0941L5| XZCPV1041L5| XZCP1041L5| 2 m / 6.56 ft.| XZCR1509041J2| XZCR1510041J2
10 ml 32.8 ft.| XZCPV0941L10| XZCP0941L10| XZCPV1041L10| XZCP1041L10| | |

Sensors position adjustment

– Translate the sensor or object, up/down and left/right. When the setting is optimal, the stability indicator (green) is lit.
– Check sensor operation with the object and adjust the sensor, if necessary.
Telemecanique XUM4ANXBM8 Photo Electric Sensors - fig
13

Anti-interference for side by side mounting

Anti-interference system to ensure good detection even disturbed by another sensor when mounted side by side

Telemecanique XUM4ANXBM8 Photo Electric Sensors - fig
14

Anti-interference system allows a side by side installation and ensures a reliable detection.

Telemecanique XUM4ANXBM8 Photo Electric Sensors - fig
15

This Anti-interference system ensures an object detection in all conditions.

Output mode setting: Light-On or Dark-On (Light-On by default)Telemecanique XUM4ANXBM8 Photo Electric Sensors - fig
16Telemecanique XUM4ANXBM8 Photo Electric
Sensors - fig 17

Sensor sensitivity adjustment

For an accurate detection, follow the set up below. (eg. Dark objects, with holes or with small size to reflect properly the light beam).

| Light-On| Dark-On
---|---|---
Telemecanique XUM4ANXBM8 Photo Electric Sensors - fig
18| 1-Connect the sensor to the power supply (see  page 1 for the wire connection & page 7 for the  power voltage).
Before settings, start with the potentiometer at the minimum position (resulting to point A).| 1-Connect the sensor to the power supply (see page 1 for  the wire connection & page 7 for the power voltage).
Before settings, start with the potentiometer at the  minimum position (resulting to point A).
Telemecanique XUM4ANXBM8 Photo Electric Sensors - fig
19| 2-Put the object in front of the sensor. Turn clockwise the potentiometer until the output led (yellow) switches on (resulting to point B).| 2-Put the object in front of the sensor. Turn clockwise the  potentiometer until the output led (yellow) switches off (resulting to point B).
Telemecanique XUM4ANXBM8 Photo Electric Sensors - fig
20| 3-For a stable detection, turn the potentiometer clockwise until the stability led (green) switches on  & the output led (yellow) remained on (resulting to point C).| 3-For a stable detection, turn the potentiometer clockwise  until the stability led (green) switches on & the output led  (yellow) remained off (resulting to point C).
Telemecanique XUM4ANXBM8 Photo Electric Sensors - fig
21| 4-The Sensor is set and ready to detect| 4-The Sensor is set and ready to detect

Detection curves

XUM4: Diffuse reflective (0,25 m) – Object size / Sensing distance
XUM5: Diffuse reflective (1,9 m) – Object size / Sensing distance
XUM6: Diffuse reflective (1,1 m) – Object size / Sensing distanceTelemecanique XUM4ANXBM8 Photo Electric Sensors - fig
30

XUM4: Diffuse reflective (0,25 m) – Lateral displacement
XUM5: Diffuse reflective (1,9 m) – Lateral displacement
XUM6: Diffuse reflective (1,1 m) – Lateral displacementTelemecanique
XUM4ANXBM8 Photo Electric Sensors - fig 31

XUM4: Diffuse reflective (0,25 m) – Excess gain
XUM5: Diffuse reflective (1,9 m) – Excess gain
XUM6: Diffuse reflective (1,1 m) – Excess gainTelemecanique XUM4ANXBM8 Photo
Electric Sensors - fig 32

Characteristics

Certification CE – UKCA – cULus

Sensing Range
(using a white paper 200 x 200)
Max. sensing distance (excess gain=1)| XUMS: 1,9 m – excess gain =1 1,5 m – excess gain=2
XUM6: 1,1 m – excess gain =1 0,8 m – excess gain=2
XUM4: 0,25 m – excess gain =1 0,17 m – excess gain=2
Color of detection light beam| XUM6: Red – XUM5 / XUM4: Infrared
Blind zone| XUM4 / XUM5 / XUM6: 10 mm
Hysteresis| 2% < H < 20% (at most sensitivity, white paper)
Sensing distance setting| Potentiometer 1 turn (- 240 degres)
Light-On/Dark-On selection| Switch (- 120 degres)
Output type| PNP or NPN
ON Voltage drop| 2 V max. (30 Vdc 100 mA) / 1,2 V max. (30 Vdc 10mA)
Current consumption| < 20 mA max.
Switching capacity| 100 mA
Response time| 0,5 ms max.
Recovery time| 0,5 ms max.
Switching frequency| 1000 Hz
Electrostatic discharge immunity| 4 kV (Contact), 8 kV (Air) conforming to IEC 61000-4-2
Electromagnetic field immunity| 10 V/m conforming to IEC 61000-4-3
Burst 5 kHz – 2kV conforming to IEC 61000-4-4
Fast transients immunity
Conducted disturbances immunity| 10 V conforming to IEC 61000-4-6
Emissivity Radiated disturbances| Class A conforming to EN 55011 / CISPR 11
Power Voltage| Rated operational voltage: 12…24 Vdc Ripple p-p 10% maximum Operating range: 10…30 Vdc (including ripple) ****
Product protection| Power supply : Reverse polarity protection Output: Short circuit protection
Reverse polarity protection
Light Immunity| Operating atmosphere; Sunlight 40 kLx max.
Incandescent light 10 kLx max.
Ambient Temperature| Operating : – 30…+55 °C (-22…+131 °F), Storage : – 40…+70 °C (-40…+158 °F)
Ambient Humidity| Operating : 35…95% RH, Storage : 35…95% RH
Degree of protection| IP65, IP67 conforming to EN/IEC 60529
Vibration resistance| Frequency range: 10 Hz to 500 Hz Acceleration: 9 gn
Shock resistance| Peak acceleration: 100 gn Duration of the pulse: 11 ms
Material| Housing: PBT, Lens: PMMA, Operation cover: PC, Adjustment potentiometer: PBT

Telemecanique XUM4ANXBM8 Photo Electric Sensors - fig
2Telemecanique XUM4ANXBM8 Photo Electric
Sensors - qr codehttp://qr.tesensors.com/XU0007
Scan the Qr-code to access this
Instruction Sheet in different languages or you can download this from our website at: www.tesensors.com

We welcome your comments about this document. You can reach us through the customer support page on your local website.

Manufacturer :
Schneider Electric Industries SAS
35 rue Joseph Monier
92500 Rueil Malmaison
France

UK Representative :
Schneider Electric Limited
Stafford Park 5
Telford, TF3 3BL
United Kingdom