Telemecanique Sensors XCSC503 Safety Door Switches Instructions

June 9, 2024
Telemecanique Sensors

Telemecanique Sensors XCSC503 Safety Door Switches Instructions
Telemecanique Sensors XCSC503 Safety Door Switches

Safety interlock switch

Safety interlock switch

QR CODE

These devices have been designed to be in compliance with the standards currently in effect: EN/IEC 60947-5-1, EN/ISO 13849-1, EN/IEC 62061, EN/IEC 60947-1, EN/ISO 14119, EN/IEC 60204. These devices can achieve up to category 4 PL=e or SIL 3 (if combined with an appropriate Control Safety Unit PL=e / SIL 3).

Dimensions

1/2’’ NPT : in case of connection by a metal conduit, a flexible metal conduit shall be used.
Max. conduit torque : 9 N.m / 80 Lb.in

DIMENSION
DIMENSION
DIMENSION

DIMENSION

DIMENSION

Shim provided with XCSZ01 enabling an XCK-J with a ZCKY07 key to be replaced by an XCS-A/B/C with an XCSZ01 key without redrilling any attaching holes.

DIMENSION

Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material.

Tongued key actuation radi

Tongued key actuation
Tongued key actuation

Head orientation

Head orientation

Tightening torque

Tightening torque

Adjustment of tongued keys

The safety interlock switch must not be used as a mechanical stop or as a centring tool for the moving guard. An additional limit stop on the fixed part must be anticipated. After adjustment, make it impossible to dismantle the support key. Only keys XCSZ 01/02/03/05 must be used.

Adjustment of tongued keys

Contact status
  • Contact closed (1)
  • Contact open (0)
  • Transient state
    Contact status

Position of keylock on XCS-B/C

Position of keylock on XCS-B/C
Position of keylock on XCS-B/C

Wiring diagram

For mechanical/electrical redundancy, add another switch with positive opening contacts.

Cat. 1 – PL=c (EN/ISO 13849-1)
XCSA5••
XCSB5••
XCSC5••
NC + NO + NO

Check that starting cannot be carried out when the protector is opened.

Wiring diagram

Cat. 3* – PL=d (EN/ISO 13849-1)
XCSA7••
XCSB7••
XCSC7••
NO + NC + NC

Wiring diagram

Maintenance

It is imperative to check the following points regularly

  • the mechanical adjustment of product XCS/A/B/C with the XCSZ01/02/03/05 tongued key
  • wear: the devices should not be used beyond the characteristics stated in catalogues
  • make sure of t he good electric switching
  • it is forbidden to modify the devices.
    Any and all liability shall be excluded in case of non compliance with the requirements of this notice

DANGER

HAZARD OF ELECTRIC SHOCK, BURN OR EXPLOSION
Turn off all power before working on this equipment. Failure to follow these instructions will result in death or serious injury.

CAUTION

INCORRECT INSTALLATION

  • All spare tongued keys must be stored in a safe place and only used or installed by authorized persons.
  • Use of a master key, modified or dummy tongued key may give rise to dangerous situations.
  • Tongued keys must be fixed by soldering, riveting or unretractable screws.
    Failure to follow these instructions can result in equipment damage.

Characteristics

Product certifications UL, CSA, CCC, EAC
Ambient air temperature Operation : -25…+70 C° / -13…158 F°………..Storage :

-40…+70 C° / -40…158 F°
Vibration resistance| 5 gn (10-500 Hz) conforming to EN/IEC 60068-2-6
Shock resistance| 10 gn (11 ms) conforming to EN/IEC 60068-2-27
Number of operations| XCSA: 106
– XCSB/C: 0,6 x 106
Reliability data B10d| XCSA: 5.000.000 – XCSB/C: 3.000.000 (data value for a service life of 20 years can be limited by contact and mechanical wear)
Rated electric characteristics of use| a AC-15, A300 : Ue = 240 V, Ie = 3 A or Ue = 120 V, Ie = 6 A
c DC-13, Q300: Ue = 250 V, Ie = 0,27 A or Ue = 125 V, Ie = 0,55 A conforming to IEC 60 947-5-1, EN 60 947-5-1
Protection against electric shock| Class I conforming to EN/IEC 61140
Actuation speed| mini = 0,01 m/s (0.39 in/s) – maxi = 0,5 m/s (19.68 in/s)
Short-circuit protection| 10 A gG (gl) cartridge fuse (use type CC in the United States)
Cable connection| Screw clamps terminals…………………… Clamping capacity : min : 1

20 AWG (1 x 0.5 mm2

Minimum key pull-out resistance| XCSA: F min = 20 N / 4.5 lbf
Resistance to forcible withdrawal of actuator| XCSB/C: F1max=1500N / 337.2 lbf, fZh=1150N / 258.5 lbf

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals