respekta CH 22010 SB Inclined Cooker Hoods Instruction Manual

June 4, 2024
respekta

respekta CH 22010 SB Inclined Cooker Hoods

respekta CH 22010 SB Inclined Cooker Hoods-fig2

General installation overview:

respekta CH 22010 SB Inclined Cooker Hoods-fig3

Content:

  • Mounting the V-Flap
  • Installation of the hood for recirculation mode
  • Mounting the hood for exhaust air operation
    Before beginning, make sure the power supply is secure. This must be set up by a specialist.
    Attention! Before installing the hood, insert the V-Flaps as described below:

INSTALLATION INSTRUCTION

If the valve flaps are not factory-mounted:

  • First install half part 1 in connection nozzle B10
  • Pins 3 must be in upwards position.
  • Insert the axle 4 into the holes 5 on the nozzle B10.
  • Repeat all operations for mounting the half part 2.

Montage der Haube für Umluftbetrieb:

  1. Using pencil, draw a horizontal line at the height on the wall on which the hood bottom edge should lie. (It is best to use a water level) Attention! Observe minimum distance according to chapter 11.1 of the operating instructions.
  2. Hold the supplied drill template with the bottom edge on the drawn pencil line against the wall and mark the four drill holes. (Fig. a)
  3. Drill a 30mm deep hole in the wall with an 8mm masonry drill at the 4 pencil marks. For safety, check the diameter of the plugs with a caliper gauge.
  4. Place one plug into each of the 4 holes.
  5. Screw a ST4 × 30mm screw into the two upper dowels (Fig. a) Attention! The screw heads must protrude 3 – 5 mm out of the dowels so that the hood can be hanged on them. (maybe readjust)
  6. Hang the hood with the two eyelets on its back (Fig. b) by the two screws on the wall.
  7. Mount the stabilizer- and mounting plate at the top of the lower flue with two ST4 * 8mm screws (Fig. c)
  8. Place the lower chimney shaft on the hood.
  9. Firmly press the chimney shaft against the wall and mark with pencil the two drill holes through the holes in the chimney stabilize- and mounting plate. (Fig. d)
  10.  Remove the chimney from the hood.
  11. Drill two 40mm deep holes into the wall at the marked locations using an 8mm masonry drill.
  12. Push the upper (inner) chimney shaft from above into the lower (outer) chimney shaft.
  13. Place the nested chimneys on the hood.respekta CH 22010 SB Inclined Cooker Hoods-fig5
  14. Pull the inner chimney shaft straight up to the ceiling and place one marking line on the sides of the shaft. (Fig. e)
  15. Remove the chimneys from the hood.
  16. Hold the upper (inner) chimney mounting bracket (Fig. f) at the top center of the ceiling between the drawn marks (Fig. e) and mark the drilled holes with the two holes (Fig. f) in the mounting bracket a pencil.
  17. Using an 8mm masonry drill, drill two 40mm deep holes at the pencil markers and place two plugs.
  18. Fix the inner chimney mounting bracket (Fig. f) to the wall with two ST4 × 40mm screws at the top of the ceiling.
  19. Place the two nested chimneys on the hood.
  20. Slide the inner chimney shaft all the way down.
  21. Attach the lower chimney stabilize- and mounting plate (Fig.d) to the wall with two ST4 x 40mm screws.
  22. Fix the lower chimney shaft with two ST4 * 8mm screws on the sides of the hood (Fig. g).
  23. Pull the upper (inner) chimney shaft all the way up and secure it to the mounting bracket with two ST4 * 8mm screws. (Fig. h)
  24. Lift the hoods on the front, remove the grease filter and secure the hood from the inside with two ST4 × 30mm screws through the 2 holes in the hood back panel to secure the hood. (Fig. i)
  25. Mount the carbon filters on the sides of the motor. (See user’s manual chapter
    “Using the carbon filters”).

Mounting the hood for exhaust air operation:

  • Attention! Be sure to observe chapter 11. “Installation” of user’s manual.
  • The wall duct must be dimensioned for a 150 mm exhaust hose. (Drill hole about 155mm).
  • To mount the hood in exhaust air mode, mount it as described in the above chapter: “Mounting the hood for recirculation mode:” , but without mounting the carbon filters.
  • Proceed as follows during assembly:
    1. Remove the outer and inner chimney.
    2. Mount the exhaust hose. (Fig. k)
    3. Replace the outer and inner chimney shaft.
      For the final assembly of the hood in exhaust air operation, you need an exhaust grille with a 150mm socket (a) for the connection of the exhaust air hose. This is not included in the delivery.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

respekta User Manuals

Related Manuals