RUUD RA14AZ-18 Endeavor Achiever Series iM Air Conditioner User Manual

June 12, 2024
RUUD

RUUD RA14AZ-18 Endeavor Achiever Series iM Air Conditioner

RUUD-RA14AZ-18-Endeavor-Achiever-Series-iM-Air-Conditioner-
PRODUCT

RA14AZ

  • Cooling Efficiency up to: 14.3 SEER2/11.7 EER2
  • Nominal Sizes: 11/2 to 5 Ton [5.28 to 17.6 kW]
  • Cooling Capacities: 17.1 to 55.5 kBTU [5.0 to 16.3 kW]

Standard Feature Table

RUUD-RA14AZ-18-Endeavor-Achiever-Series-iM-Air-Conditioner-
FIG-1

Features and Benefits

  • Lighter Footprint & Less Environmental Impact from New 7mm Condenser Coil provided by a decrease in refrigerant requirements and an overall weight reduction
  • Efficient Cooling up to 14.3 SEER2/11.7 EER2
  • PlusOne Expanded Value Space: 3in – 4in – 5 in service valve space – provides a minimum working area of 27-square inches for easier access
  • PlusOne Triple Service Access: 15 in-wide, industry-leading corner service access – makes repairs easier and faster. The two fasteners, removable corner allows optimal access to internal unit components. Individual louver panels come out once fastener is removed, for faster coil cleaning and easier cabinet reassembly
  • System Matching Simplicity – matches to all tiers of gas furnaces
  • Modern cabinet aesthetics – High curb appeal with visually appealing design
  • Curved louver panels – provide ultimate coil protection, enhance cabinet strength, and increased cabinet rigidity
  • A diagnostic service window with a two-fastener opening –provides access to the high and low pressure.
  • External gauge port access – allows easy connection of “low-loss” gauge ports
  • QR code – provides technical information on demand for faster service calls
  • Fan motor harness with extra-long wires allows the unit top to be removed without disconnecting fan wire.

Air Conditioners

RUUD-RA14AZ-18-Endeavor-Achiever-Series-iM-Air-Conditioner-
FIG-2

  • [ ] Designates Metric Conversions

Available SKUs

Available Models Description
RA14AZ18AJ1NA Endeavor™ Line Achiever ® Series iM Air Conditioner 1 1/2

ton 14.3 SEER2 Single-Stage Air Conditioner-208/230/1/60
RA14AZ18AJ1NALHP| Endeavor™ Line Achiever ® Series iM Air Conditioner 1 1/2 ton 14.3 SEER2 Single-Stage Air Conditioner w/ High/Low Pressure-208/230/1/60
RA14AZ24AJ1NA| Endeavor™ Line Achiever ® Series iM Air Conditioner 2 ton 14.3 SEER2 Single-Stage Air Conditioner-208/230/1/60
RA14AZ24AJ1NALHP| Endeavor™ Line Achiever ® Series iM Air Conditioner 2 ton 14.3 SEER2 Single-Stage Air Conditioner w/ High/Low Pressure-208/230/1/60
RA14AZ30AJ1NA| Endeavor™ Line Achiever ® Series iM Air Conditioner 2 1/2 ton 14.3 SEER2 Single-Stage Air Conditioner-208/230/1/60
RA14AZ30AJ1NALHP| Endeavor™ Line Achiever ® Series iM Air Conditioner 2 1/2 ton 14.3 SEER2 Single-Stage Air Conditioner w/ High/Low Pressure-208/230/1/60
RA14AZ36AJ1NA| Endeavor™ Line Achiever ® Series iM Air Conditioner 3 ton 14.3 SEER2 Single-Stage Air Conditioner-208/230/1/60
RA14AZ36AJ1NALHP| Endeavor™ Line Achiever ® Series iM Air Conditioner 3 ton 14.3 SEER2 Single-Stage Air Conditioner w/ High/Low Pressure-208/230/1/60
RA14AZ42AJ1NA| Endeavor™ Line Achiever ® Series iM Air Conditioner 3 1/2 ton 14.3 SEER2 Single-Stage Air Conditioner-208/230/1/60
RA14AZ42AJ1NALHP| Endeavor™ Line Achiever ® Series iM Air Conditioner 3 1/2 ton 14.3 SEER2 Single-Stage Air Conditioner w/ High/Low Pressure-208/230/1/60
RA14AZ48AJ1NA| Endeavor™ Line Achiever ® Series iM Air Conditioner 4 ton 14.3 SEER2 Single-Stage Air Conditioner-208/230/1/60
RA14AZ48AJ1NALHP| Endeavor™ Line Achiever ® Series iM Air Conditioner 4 ton 14.3 SEER2 Single-Stage Air Conditioner w/ High/Low Pressure-208/230/1/60
RA14AZ60AJ1NA| Endeavor™ Line Achiever ® Series iM Air Conditioner 5 ton 14.3 SEER2 Single-Stage Air Conditioner-208/230/1/60
RA14AZ60AJ1NALHP| Endeavor™ Line Achiever ® Series iM Air Conditioner 5 ton 14.3 SEER2 Single-Stage Air Conditioner w/ High/Low Pressure-208/230/1/60
General Data

GENERAL DATA
Model No.| RA14AZ18| RA14AZ24| RA14AZ30| RA14AZ36| RA14AZ42| RA14AZ48| RA14AZ60
Nominal Tonnage| 1.5| 2.0| 2.5| 3.0| 3.5| 4.0| 5.0
Valve Connections|
Liquid Line O.D. – in.| 3/8| 3/8| 3/8| 3/8| 3/8| 3/8| 3/8
Suction Line O.D. – in.| 3/4| 3/4| 3/4| 3/4| 7/8| 7/8| 7/8
Refrigerant (R410A) furnished oz.¹| 94| 115| 120| 124| 149| 153| 203
Compressor Type| Scroll
Outdoor Coil|
Net face area – Outer Coil| 10.9| 13.3| 14.3| 16.4| 19.5| 19.5| 32.5
Net face area – Inner Coil| 10.5| 12.9| 13.9| 15.9| 18.8| 18.8| —
Tube diameter – in.| 0.276| 0.276| 0.276| 0.276| 0.276| 0.276| 3/8
Number of rows| 2| 2| 2| 2| 2| 2| 1
Fins per inch| 24| 24| 24| 24| 24| 24| 22
Outdoor Fan|
Diameter – in.| 20| 24| 24| 24| 24| 24| 26
Number of blades| 2| 2| 2| 2| 3| 3| 3
Motor hp| 1/7| 1/6| 1/6| 1/6| 1/5| 1/5| 1/3
CFM| 2156| 2723| 2830| 2991| 3655| 3655| 5178
RPM| 1075| 825| 825| 825| 850| 850| 910
watts| 152| 161| 165| 145| 214| 214| 271
Shipping weight – lbs.| 151| 185| 171| 185| 236| 228| 294
Operating weight – lbs.| 144| 178| 164| 178| 229| 221| 287
Electrical Data| | | | | | |
Line Voltage Data (Volts-Phase-Hz)| 208/230-1-60| 208/230-1-60| 208/230-1-60| 208/230-1-60| 208/230-1-60| 208/230-1-60| 208/230-1-60
Maximum overcurrent protection (amps)²| 20| 25| 30| 30| 40| 40| 60
Minimum circuit ampacity³| 14| 18| 19| 20| 24| 24| 40
Compressor
Rated load amps| 9| 12| 14| 13| 18| 18| 26
Locked rotor amps| 43| 60| 68| 83| 110| 102| 150
Condenser Fan Motor
Full load amps| 0.8| 0.8| 0.8| 0.8| 1.0| 1.0| 2.8
Locked rotor amps| 1.5| 1.5| 1.7| 1.7| 2.6| 2.6| —

  1. Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the installation instructions for information about set length and additional refrigerant charge required.
  2. HACR type circuit breaker of the fuse.
  3. Refer to the National Electrical Code manual to determine wire, fuse and disconnect size requirements.

Accessories

Model No.| RA14AZ18| RA14AZ24| RA14AZ30| RA14AZ36| RA14AZ42| RA14AZ48| RA14AZ60
---|---|---|---|---|---|---|---
Compressor crankcase heater*| 44-17402-44| 44-17402-44| 44-17402-44| 44-17402-44| 44-17402-45| 44-17402-45| 44-17402-45
Low ambient control| RXAD-A08| RXAD-A08| RXAD-A08| RXAD-A08| RXAD-A08| RXAD-A08| RXAD-A08
Compressor sound cover| 68-23427-26| 68-23427-26| 68-23427-26| 68-23427-26| 68-23427-25| 68-23427-25| 68-23427-25
Compressor hard start kit| SK-A1| SK-A1| SK-A1| SK-A1| SK-A1| SK-A1| SK-A1
Compressor time delay| RXMD-B01| RXMD-B01| RXMD-B01| RXMD-B01| RXMD-B01| RXMD-B01| RXMD-B01
Low-pressure control| RXAC-A07| RXAC-A07| RXAC-A07| RXAC-A07| RXAC-A07| RXAC-A07| RXAC-A07
High-pressure control| RXAB-A07| RXAB-A07| RXAB-A07| RXAB-A07| RXAB-A07| RXAB-A07| RXAB-A07
Liquid Line Solenoid (24 VAC, 50/60 Hz)| Solenoid Valve| 200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC
Solenoid Coil| 61-AMG24V| 61-AMG24V| 61-AMG24V| 61-AMG24V| 61-AMG24V| 61-AMG24V| 61-AMG24V
Liquid Line Solenoid (120/240 VAC, 50/60 Hz)| Solenoid Valve| 200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC
Solenoid Coil| 61-AMG120/240V| 61-AMG120/240V| 61-AMG120/240V| 61-AMG120/240V| 61-AMG120/240V| 61-AMG120/240V| 61-AMG120/240V
Classic Top Cap w/Label| 91-101123-21| 91-101123-21| 91-101123-21| 91-101123-21| 91-101123-21| 91-101123-21| 91-101123-21

Weighted Sound Power Level (dBA)

Unit Size – Voltage, Series| Standard Rating (dBA)| TYPICAL OCTAVE BAND SPECTRUM (dBA without tone adjustment)
---|---|---
125| 250| 500| 1000| 2000| 4000| 8000
RA14AZ18| 70.7| 48.2| 56.0| 61.9| 61.0| 56.5| 53.5| 45.7
RA14AZ24| 75.7| 46.5| 62.0| 68.1| 64.5| 60.8| 55.2| 48.4
RA14AZ30| 76.8| 48.2| 62.5| 68.8| 65.8| 62.0| 57.2| 49.6
RA14AZ36| 76.1| 48.4| 58.7| 67.3| 65.5| 62.6| 58.8| 52.1
RA14AZ42| 72.5| 46.6| 55.3| 63.9| 62.1| 59.4| 55.2| 48.2
RA14AZ48| 74.0| 45.4| 55.7| 64.2| 62.9| 60.8| 56.7| 51.2
RA14AZ60| 75.8| 43.4| 59.8| 67.2| 65.5| 62.7| 59.2| 53.1

NOTE: Tested in accordance with AHRI Standard 270-08 (not listed in AHRI)

Unit Dimensions


MODEL NO.

| OPERATING| SHIPPING
---|---|---
H (Height)| L (Length)| W (Width)| H (Height)| L (Length)| W (Width)
INCHES| mm| INCHES| mm| INCHES| mm| INCHES| mm| INCHES| mm| INCHES| mm
RA14AZ18| 25.00| 635| 29.75| 756| 29.75| 756| 26.50| 673| 32.38| 822| 32.38| 822
RA14AZ24| 25.00| 635| 33.75| 857| 33.75| 857| 26.50| 673| 36.38| 924| 36.38| 924
RA14AZ30| 27.00| 686| 33.75| 857| 33.75| 857| 28.50| 724| 36.38| 924| 36.38| 924
RA14AZ36| 31.00| 787| 33.75| 857| 33.75| 857| 32.50| 826| 36.38| 924| 36.38| 924
RA14AZ42| 35.00| 889| 33.75| 857| 33.75| 857| 36.50| 927| 36.38| 924| 36.38| 924
RA14AZ48| 35.00| 889| 33.75| 857| 33.75| 857| 36.50| 927| 36.38| 924| 36.38| 924
RA14AZ60| 51.00| 1295| 35.75| 908| 35.75| 908| 52.50| 1334| 38.38| 975| 38.38| 975

RUUD-RA14AZ-18-Endeavor-Achiever-Series-iM-Air-Conditioner-
FIG-3

CLEARANCES

RUUD-RA14AZ-18-Endeavor-Achiever-Series-iM-Air-Conditioner-
FIG-4

Control Wiring

RUUD-RA14AZ-18-Endeavor-Achiever-Series-iM-Air-Conditioner-
FIG-5

Application Guidelines

  1. Intended for outdoor installation with free air inlet and outlet. The outdoor fan external static pressure available is less than 0.01 -in. WC.
  2. The minimum outdoor operation air temperature for a cooling mode without a low-ambient operation accessory is 55°F (12.8°C).
  3. The maximum outdoor operating air temperature is 125°F (51.7°C).
  4. For reliable operation, the unit should be level in all horizontal planes.
  5. Use only copper wire for electric connections at the unit. Aluminum and clad aluminum are not acceptable for the type of connector provided.
  6. Do not apply capillary tube indoor coils to these units.
  7. Factory–supplied filter drier must be installed.

Refrigerant Line Size Information

14.3 SEER2 Single-Stage Air-Conditioners



Unit Size

| ****

Allowable Liquid Line Size

| ****

Allowable Suction Line Size

| Apply Long Line Guidelines if Linear Line Length Exceeds Those Shown Below (Feet)| Equivalent Length (Feet)
< 25| 26-50| 51-75| 76-100| 101-125| 126-150| 151-175| 176-200| 201-225| 226-250
(-)A14AZ| *Maximum Vertical Rise (Outdoor Unit Below Indoor Unit) / Capacity Multiplier**



1.5 Ton

**SEE NOTE 3

| 1/4″| 5/8″| N/A| 25 / 1.00| 50 / 0.99| 62 / 0.98| 43 / 0.98| 24 / 0.97| 5 / 0.97| NR| NR| NR| NR
5/16″| 5/8″| 223| 25 / 1.00| 50 / 0.99| 75 / 0.98| 98 / 0.98| 93 / 0.97| 88 / 0.97| 83 / 0.96| 78 / 0.96| 73 / 0.95| 68 / 0.94
3/8″| 5/8″| 148| 25 / 1.00| 50 / 0.99| 75 / 0.98| 100 / 0.98| 100 / 0.97| 100 / 0.97| 100 / 0.96| 100 / 0.96| 100 / 0.95| 100 / 0.94
1/4″| 3/4″| N/A| 25 / 1.00| 50 / 1.00| 62 / 0.99| 43 / 0.99| 24 / 0.99| 5 / 0.99| NR| NR| NR| NR
5/16″| 3/4″
| 223| 25 / 1.00| 50 / 1.00| 75 / 0.99| 98 / 0.99| 93 / 0.99| 88 / 0.99| 83 / 0.99| 78 / 0.98| 73 / 0.98| 68 / 0.98
3/8″| 3/4″**| 148| 25 / 1.00| 50 / 1.00| 75 / 1.00| 100 / 0.99| 100 / 0.99| 100 / 0.99| 100 / 0.99| 100 / 0.98| 100 / 0.98| 100 / 0.98




2 Ton

| 1/4″| 5/8″| N/A| 25 / 0.99| 50 / 0.98| 21 / 0.97| NR| NR| NR| NR| NR| NR| NR
5/16″| 5/8″| 213| 25 / 0.99| 50 / 0.98| 75 / 0.97| 87 / 0.96| 77 / 0.95| 69 / 0.94| 61 / 0.93| 53 / 0.92| 45 / 0.91| 37 / 0.90
3/8″| 5/8″| 142| 25 / 0.99| 50 / 0.98| 75 / 0.97| 100 / 0.96| 100 / 0.95| 100 / 0.94| 98 / 0.93| 95 / 0.92| 92 / 0.91| 89 / 0.90
1/4″| 3/4″| N/A| 25 /1.00| 50 / 1.00| 21 / 0.99| NR| NR| NR| NR| NR| NR| NR
5/16″| 3/4″| 213| 25 /1.00| 50 / 1.00| 75 / 0.99| 87 / 0.99| 77 / 0.98| 69 / 0.98| 61 / 0.98| 53 / 0.97| 45 / 0.97| 37 / 0.96
3/8″| 3/4″| 142| 25 / 1.00| 50 / 1.00| 75 / 0.99| 100 / 0.99| 100 / 0.98| 100 / 0.98| 98 / 0.98| 95 / 0.97| 93 / 0.97| 90 / 0.96



2.5 Ton

| 5/16″| 5/8″| N/A| 25 / 0.99| 50 / 0.98| 75 / 0.96| 70 / 0.94| 59 / 0.93| 48 / 0.91| 36 / 0.90| NR| NR| NR
3/8″| 5/8″| 117| 25 / 0.99| 50 / 0.98| 75 / 0.96| 100 / 0.94| 98 / 0.93| 94 / 0.91| 90 / 0.90| NR| NR| NR
5/16″| 3/4″| 175| 25 / 1.00| 50 / 0.99| 75 / 0.99| 70 / 0.98| 59 / 0.98| 48 / 0.97| 36 / 0.96| 25 / 0.96| 13 / 0.95| NR
3/8″| 3/4″| 117| 25 / 1.00| 50 / 0.99| 75 / 0.99| 100 / 0.98| 98 / 0.98| 94 / 0.97| 90 / 0.96| 86 / 0.96| 82 / 0.95| 78 / 0.95





3 Ton

| 5/16″| 5/8″| N/A| 25 / 0.99| 50 / 0.97| 66 / 0.94| 49 / 0.92| 32 / 0.90| NR| NR| NR| NR| NR
3/8″| 5/8″| 85| 25 / 0.99| 50 / 0.97| 75 / 0.94| 95 / 0.92| 89 / 0.90| NR| NR| NR| NR| NR
5/16″| 3/4″| 128| 25 / 1.00| 50 / 0.99| 66 / 0.98| 49 / 0.98| 32 / 0.97| 15 / 0.96| NR| NR| NR| NR
3/8″| 3/4″| 85| 25 / 1.00| 50 / 0.99| 75 / 0.98| 95 / 0.98| 89 / 0.97| 84 / 0.96| 78 / 0.95| 72 / 0.94| 67 / 0.93| 61 / 0.93
1/2″| 3/4″| 43| 25 / 1.00| 50 / 0.99| 75 / 0.98| 100 / 0.98| 100 / 0.97| 100 / 0.96| 100 / 0.95| 100 / 0.94| 100 / 0.93| 100 / 0.93
5/16″| 7/8″| 128| 25 / 1.00| 50 / 1.00| 66 / 1.00| 49 / 0.99| 32 / 0.99| 15 / 0.99| NR| NR| NR| NR
3/8″| 7/8″| 85| 25 / 1.00| 50 / 1.00| 75 / 1.00| 95 / 0.99| 89 / 0.99| 84 / 0.99| 78 / 0.98| 72 / 0.98| 67 / 0.98| 61 / 0.97
1/2″| 7/8″| 43| 25 / 1.00| 50 / 1.00| 75 / 1.00| 100 / 0.99| 100 / 0.99| 100 / 0.99| 100 / 0.98| 100 / 0.98| 100 / 0.98| 100 / 0.97



3.5 Ton

| 3/8″| 3/4″| 102| 25 / 0.99| 50 / 0.98| 75 / 0.97| 88 / 0.96| 80 / 0.95| 72 / 0.94| 65 / 0.92| 57 / 0.91| 49 / 0.90| NR
1/2″| 3/4″| 51| 25 / 0.99| 50 / 0.98| 75 / 0.97| 100 / 0.96| 100 / 0.95| 100 / 0.94| 100 / 0.92| 100 / 0.91| 100 / 0.90| NR
3/8″| 7/8″| 102| 25 / 1.00| 50 / 1.00| 75 / 0.99| 88 / 0.99| 80 / 0.99| 72 / 0.98| 65 / 0.97| 57 / 0.97| 49 / 0.96| 42 / 0.96
1/2″| 7/8″| 51| 25 / 1.00| 50 / 1.00| 75 / 0.99| 100 / 0.99| 100 / 0.99| 100 / 0.98| 100 / 0.97| 100 / 0.97| 100 / 0.96| 100 / 0.96

NOTES:

  1. Do not exceed 200 ft linear line length.
  2. Do not exceed 100 ft vertical separation if the outdoor unit is above the indoor unit.
  3. 3/4″ suction line should only be used for 1.5-ton systems if the outdoor unit is below or at the same level as the indoor to assure proper oil return.
  4. Always use the smallest liquid line allowable to minimize refrigerant charge.
  5. Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended but are allowed.
  6. Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop.

Refrigerant Line Size Information (con’t.)

14.3 SEER2 Single-Stage Air-Conditioners



Unit Size

| ****

Allowable Liquid Line Size

| ****

Allowable Suction Line Size

| Apply Long Line Guidelines if Linear Line Length Exceeds Those Shown Below (Feet)| Equivalent Length (Feet)
< 25| 26-50| 51-75| 76-100| 101-125| 126-150| 151-175| 176-200| 201-225| 226-250
(-)A14AZ| *Maximum Vertical Rise (Outdoor Unit Below Indoor Unit) / Capacity Multiplier**



4 Ton

| 3/8″| 3/4″| 110| 25 / 0.99| 50 / 0.98| 75 / 0.96| 77 / 0.95| 67 / 0.93| 57 / 0.92| 46 / 0.91| NR| NR| NR
1/2″| 3/4″| 55| 25 / 0.99| 50 / 0.98| 75 / 0.96| 100 / 0.95| 100 / 0.93| 100 / 0.92| 100 / 0.91| NR| NR| NR
3/8″| 7/8″| 110| 25 / 1.00| 50 / 0.99| 75 / 0.99| 77 / 0.98| 67 / 0.97| 57 / 0.97| 46 / 0.96| 36 / 0.96| 26 / 0.95| 15 / 0.95
1/2″| 7/8″| 55| 25 / 1.00| 50 / 0.99| 75 / 0.99| 100 / 0.98| 100 / 0.97| 100 / 0.97| 100 / 0.96| 100 / 0.96| 99 / 0.95| 97 / 0.95




5 Ton

| 3/8″| 3/4″| 0| 25 / 0.99| 50 / 0.97| 75 / 0.94| 61 / 0.92| 46 / 0.90| NR| NR| NR| NR| NR
1/2″| 3/4″| 0| 25 / 0.99| 50 / 0.97| 75 / 0.94| 100 / 0.92| 100 / 0.90| NR| NR| NR| NR| NR
3/8″| 7/8″| 0| 25 / 1.00| 50 / 0.99| 75 / 0.98| 61 / 0.97| 46 / 0.96| 32 / 0.95| 18 / 0.94| NR| NR| NR
1/2″| 7/8″| 0| 25 / 1.00| 50 / 0.99| 75 / 0.98| 100 / 0.97| 100 /0.96| 100 / 0.95| 97 / 0.94| 95 / 0.94| 92 / 0.93| 89 / 0.92
3/8″| 1-1/8″| 0| 25 / 1.01| 50 / 1.01| 75 / 1.00| 61 / 1.00| 46 / 0.99| 32 / 0.99| 18 / 0.99| NR| NR| NR
1/2″| 1-1/8″| 0| 25 / 1.01| 50 / 1.01| 75 / 1.00| 100 /1.00| 100 / 0.99| 100 / 0.99| 97 / 0.99| 95 / 0.99| 92 / 0.99| 89 / 0.98

NOTES

  1. Do not exceed 200 ft linear line length.
  2. Do not exceed 100 ft vertical separation if the outdoor unit is above the indoor unit.
  3. A 3/4″ suction line should only be used for 1.5-ton systems if the outdoor unit is below or at the same level as the indoor to assure proper oil return.
  4. Always use the smallest liquid line allowable to minimize refrigerant charge.
  5. Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended but are allowed.
  6. Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop.

Refrigerant Line Size Information

14.3 SEER2 Single-Stage Air-Conditioners



Unit Size

| ****

Allowable Liquid Line Size

mm [in.]

| ****

Allowable Suction Line Size

mm [in.]

| Apply Long Line Guidelines if Linear Line Length Exceeds Those Shown Below (Feet)| Equivalent Length (Meters)
< 8| 8-15| 16-23| 24-30| 31-38| 39-46| 47-53| 54-61| 62-69| 70-76
(-)A14AZ| *Maximum Vertical Rise (Outdoor Unit Below Indoor Unit) / Capacity Multiplier**



5.3 KW [1.5 Ton]

**SEE NOTE 3

| 6.35 [1/4]| 15.88 [5/8]| N/A| 8 / 1.00| 15 / 0.99| 19 / 0.98| 13 / 0.98| 7 / 0.97| 2 / 0.97| NR| NR| NR| NR
7.94 [5/16]| 15.88 [5/8]| 68| 8 / 1.00| 15 / 0.99| 23 / 0.98| 30 / 0.98| 28 / 0.97| 27 / 0.97| 25 / 0.96| 24 / 0.96| 22 / 0.95| 21 / 0.94
9.53 [3/8]| 15.88 [5/8]| 45| 8 / 1.00| 15 / 0.99| 23 / 0.98| 30 / 0.98| 30 / 0.97| 30 / 0.97| 30 / 0.96| 30 / 0.96| 30 / 0.95| 30 / 0.94
6.35 [1/4]| 19.05 [3/4]| N/A| 8 / 1.00| 15 / 1.00| 19 / 0.99| 13 / 0.99| 7 / 0.99| 2 / 0.99| NR| NR| NR| NR
7.94 [5/16]| 19.05 [3/4]
| 68| 8 / 1.00| 15 / 1.00| 23 / 0.99| 30 / 0.99| 28 / 0.99| 27 / 0.99| 25 / 0.99| 24 / 0.98| 22 / 0.98| 21 / 0.98
9.53 [3/8]| 19.05 [3/4]**| Metric| 8 / 1.00| 15 / 1.00| 23 / 0.99| 30 / 0.99| 30 / 0.99| 30 / 0.99| 30 / 0.99| 30 / 0.98| 30 / 0.98| 30 / 0.98



7.0 KW [2 Ton]

| 6.35 [1/4]| 15.88 [5/8]| N/A| 8 / 0.99| 15 / 0.98| 6 / 0.97| NR| NR| NR| NR| NR| NR| NR
7.94 [5/16]| 15.88 [5/8]| 59| 8 / 0.99| 15 / 0.98| 23 / 0.97| 27 / 0.96| 23 / 0.95| 21 / 0.94| 19 / 0.93| 16 / 0.92| 14 / 0.91| 11 / 0.90
9.53 [3/8]| 15.88 [5/8]| 39| 8 / 0.99| 15 / 0.98| 23 / 0.97| 30 / 0.96| 30 / 0.95| 30 / 0.94| 30 / 0.93| 29 / 0.92| 28 / 0.91| 27 / 0.90
6.35 [1/4]| 19.05 [3/4]| N/A| 8 / 1.00| 15 / 1.00| 6 / 0.99| NR| NR| NR| NR| NR| NR| NR
7.94 [5/16]| 19.05 [3/4]| 59| 8 / 1.00| 15 / 1.00| 23 / 0.99| 27 / 0.99| 23 / 0.98| 21 / 0.98| 19 / 0.98| 16 / 0.97| 14 / 0.97| 11 / 0.96
9.53 [3/8]| 19.05 [3/4]| 39| 8 / 1.00| 15 / 1.00| 23 / 0.99| 30 / 0.99| 30 / 0.98| 30 / 0.98| 30 / 0.98| 29 / 0.97| 28 / 0.97| 27 / 0.96


8.8 KW [2.5 Ton]

| 7.94 [5/16]| 15.88 [5/8]| N/A| 8 / 0.99| 15 / 0.98| 23 / 0.96| 21 / 0.94| 18 / 0.93| 15 / 0.91| 11 / 0.90| NR| NR| NR
9.53 [3/8]| 15.88 [5/8]| 36| 8 / 0.99| 15 / 0.98| 23 / 0.96| 30 / 0.94| 30 / 0.93| 29 / 0.91| 27 / 0.90| NR| NR| NR
7.94 [5/16]| 19.05 [3/4]| 53| 8 / 1.00| 15 / 0.99| 23 / 0.99| 21 / 0.98| 18 / 0.98| 15 / 0.97| 11 / 0.96| 8 / 0.96| 4 / 0.95| NR
9.53 [3/8]| 19.05 [3/4]| 36| 8 / 1.00| 15 / 0.99| 23 / 0.99| 30 / 0.98| 30 / 0.98| 29 / 0.97| 27 / 0.96| 26 / 0.96| 25 / 0.95| 24 / 0.95





10.6 KW [3 Ton]

| 7.94 [5/16]| 15.88 [5/8]| N/A| 8 / 0.99| 15 / 0.97| 20 / 0.94| 15 / 0.92| 10 / 0.90| NR| NR| NR| NR| NR
9.53 [3/8]| 15.88 [5/8]| 26| 8 / 0.99| 15 / 0.97| 23 / 0.94| 29 / 0.92| 27 / 0.90| NR| NR| NR| NR| NR
7.94 [5/16]| 19.05 [3/4]| 39| 8 / 1.00| 15 / 0.99| 20 / 0.98| 15 / 0.98| 10 / 0.97| 5 / 0.96| NR| NR| NR| NR
9.53 [3/8]| 19.05 [3/4]| 26| 8 / 1.00| 15 / 0.99| 23 / 0.98| 29 / 0.98| 27 / 0.97| 26 / 0.96| 24 / 0.95| 22 / 0.94| 20 / 0.93| 19 / 0.93
12.70 [1/2]| 19.05 [3/4]| 13| 8 / 1.00| 15 / 0.99| 23 / 0.98| 30 / 0.98| 30 / 0.97| 30 / 0.96| 30 / 0.95| 30 / 0.94| 30 / 0.93| 30 / 0.93
7.94 [5/16]| 22.23 [7/8]| 39| 8 / 1.00| 15 / 1.00| 20 / 1.00| 15 / 0.99| 10 / 0.99| 5 / 0.99| NR| NR| NR| NR
9.53 [3/8]| 22.23 [7/8]| 26| 8 / 1.00| 15 / 1.00| 23 / 1.00| 29 / 0.99| 27 / 0.99| 26 / 0.99| 24 / 0.98| 22 / 0.98| 20 / 0.98| 19 / 0.97
12.70 [1/2]| 22.23 [7/8]| 13| 8 / 1.00| 15 / 1.00| 23 / 1.00| 30 / 0.99| 30 / 0.99| 30 / 0.99| 30 / 0.98| 30 / 0.98| 30 / 0.98| 30 / 0.97


12.3 KW [3.5 Ton]

| 9.53 [3/8]| 19.05 [3/4]| 31| 8 / 0.99| 15 / 0.98| 23 / 0.97| 27 / 0.96| 24 / 0.95| 22 / 0.94| 20 / 0.92| 17 / 0.91| 15 / 0.90| NR
12.70 [1/2]| 19.05 [3/4]| 15| 8 / 0.99| 15 / 0.98| 23 / 0.97| 30 / 0.96| 30 / 0.95| 30 / 0.94| 30 / 0.92| 30 / 0.91| 30 / 0.90| NR
9.53 [3/8]| 22.23 [7/8]| 31| 8 / 1.00| 15 / 1.00| 23 / 0.99| 27 / 0.99| 24 / 0.99| 22 / 0.98| 20 / 0.97| 17 / 0.97| 15 / 0.96| 13 / 0.96
12.70 [1/2]| 22.23 [7/8]| 15| 8 / 1.00| 15 / 1.00| 23 / 0.99| 30 / 0.99| 30 / 0.99| 30 / 0.98| 30 / 0.97| 30 / 0.97| 30 / 0.96| 30 / 0.96

NOTES:

  1. Do not exceed 200 ft linear line length.
  2. Do not exceed 100 ft vertical separation if the outdoor unit is above the indoor unit.
  3. 3/4″ suction line should only be used for 1.5-ton systems if the outdoor unit is below or at the same level as the indoor to assure proper oil return.
  4. Always use the smallest liquid line allowable to minimize refrigerant charge.
  5. Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended but are allowed.
  6. Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop.

Refrigerant Line Size Information (con’t.)

14.3 SEER2 Single-Stage Air-Conditioners



Unit Size

| ****

Allowable Liquid Line Size

mm [in.]

| ****

Allowable Suction Line Size

mm [in.]

| Apply Long Line Guidelines if Linear Line Length Exceeds Those Shown Below (Feet)| Equivalent Length (Meters)
< 25| 26-50| 51-75| 76-100| 101-125| 126-150| 151-175| 176-200| 201-225| 226-250
(-)A14AZ| *Maximum Vertical Rise (Outdoor Unit Below Indoor Unit) / Capacity Multiplier**


14.1 KW [4 Ton]

| 9.53 [3/8]| 19.05 [3/4]| 34| 8 / 0.99| 15 / 0.98| 23 / 0.96| 24 / 0.95| 20 / 0.93| 17 / 0.92| 14 / 0.91| NR| NR| NR
12.7 [1/2]| 19.05 [3/4]| 17| 8 / 0.99| 15 / 0.98| 23 / 0.96| 30 / 0.95| 30 / 0.93| 30 / 0.92| 30 / 0.91| NR| NR| NR
9.53 [3/8]| 22.23 [7/8]| 34| 8 / 1.00| 15 / 0.99| 23 / 0.99| 24 / 0.98| 20 / 0.97| 17 / 0.97| 14 / 0.96| 11 / 0.96| 8 / 0.95| 5 / 0.95
12.7 [1/2]| 22.23 [7/8]| 17| 8 / 1.00| 15 / 0.99| 23 / 0.99| 30 / 0.98| 30 / 0.97| 30 / 0.97| 30 / 0.96| 30 / 0.96| 30 / 0.95| 30 / 0.95



17.6 KW [5 Ton]

| 9.53 [3/8]| 19.05 [3/4]| 0| 8 / 0.99| 15 / 0.97| 23 / 0.94| 19 / 0.92| 14 / 0.90| NR| NR| NR| NR| NR
12.7 [1/2]| 19.05 [3/4]| 0| 8 / 0.99| 15 / 0.97| 23 / 0.94| 30 / 0.92| 30 / 0.90| NR| NR| NR| NR| NR
9.53 [3/8]| 22.23 [7/8]| 0| 8 / 1.00| 15 / 0.99| 23 / 0.98| 19 / 0.97| 14 / 0.96| 10 / 0.95| 5 / 0.94| NR| NR| NR
12.7 [1/2]| 22.23 [7/8]| 0| 8 / 1.00| 15 / 0.99| 23 / 0.98| 30 / 0.97| 30 /0.96| 30 / 0.95| 30 / 0.94| 29 / 0.94| 28 / 0.93| 27 / 0.92
9.53 [3/8]| 28.58 [1-1/8]| 0| 8 / 1.01| 15 / 1.01| 23 / 1.00| 19 / 1.00| 14 / 0.99| 10 / 0.99| 5 / 0.99| NR| NR| NR
12.7 [1/2]| 28.58 [1-1/8]| 0| 8 / 1.01| 15 / 1.01| 23 / 1.00| 30 / 1.00| 30 / 0.99| 30 / 0.99| 30 / 0.99| 29 / 0.99| 28 / 0.99| 27 / 0.98

NOTES

  1. Do not exceed 200 ft linear line length.
  2. Do not exceed 100 ft vertical separation if the outdoor unit is above the indoor unit.
  3. 3/4″ suction line should only be used for 1.5-ton systems if the outdoor unit is below or at the same level as the indoor to assure proper oil return.
  4. Always use the smallest liquid line allowable to minimize refrigerant charge.
  5. Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended but are allowed.
  6. Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop.

Performance Data @ AHRI Standard Conditions – Cooling

Designated Tested Combination (DTC)

Outdoor Unit| Indoor Coil| Total Capacity BTU/H [kW]| Net Sensible BTU/H [kW]| Net Latent BTU/H [kW]| SEER2| EER2| Indoor CFM [L/s]
RA14AZ18AJ1| RCFZ2417STAN| 17100 [5.0]| 13100 [3.8]| 4000 [1.2]| 14.3| 11.7| 600 [283.2]
RA14AZ24AJ1| RCFZ2417STAN| 22800 [6.7]| 17000 [5.0]| 5800 [1.7]| 14.3| 11.7| 735 [346.9]
RA14AZ30AJ1| RCFZ3617STAN| 28600 [8.4]| 20800 [6.1]| 7800 [2.3]| 14.3| 11.7| 910 [429.5]
RA14AZ36AJ1| RCFZ3617STAN| 34200 [10.0]| 25000 [7.3]| 9200 [2.7]| 14.3| 11.7| 1030 [486.1]
RA14AZ42AJ1| RCFZ4821STAN| 39500 [11.6]| 28500 [8.4]| 11000 [3.2]| 14.3| 11.7| 1295 [611.2]
RA14AZ48AJ1| RCFZ4821STAN| 46000 [13.5]| 32500 [9.5]| 13500 [4.0]| 13.8| 11.2| 1420 [670.2]
RA14AZ60AJ1| RCFZ6024STAN| 55500 [16.3]| 39500 [11.6]| 16000 [4.7]| 13.8| 11.2| 1595 [752.8]

NOTE: This data includes DTC (Designated Test Combination) ratings and is for reference purposes only. A full listing of official ratings and system match-ups, along with downloadable certificates, can be accessed from the AHRI website: www.ahridirectory.org.

[ ] Designates Metric Conversions

GENERAL TERMS OF LIMITED WARRANTY

Ruud will furnish a replacement for any part of this product that fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty.

  • For complete details of the Limited and Conditional Warranties, including applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certificate.

Conditional Parts

  • (Registration Required)……………………………. Ten (10) Years

In keeping with its policy of continuous progress and product improvement, Ruud reserves the right to make changes without notice.

  • Ruud Heating, Cooling & Water Heating
  • 5600 Old Greenwood Road
  • Fort Smith, Arkansas 72908
  • www.ruud.com