FUSION EXO Spot 30 White LED Light User Manual

June 10, 2024
FUSION

FUSION EXO Spot 30 White LED Light

FUSION-EXO-Spot-30-White-LED-Light

User Manual: Fusion EXO Spot 30

Product Information

The Fusion EXO Spot 30 is a lighting fixture manufactured by German Light Products GmbH. The fixture software version is V1.0.00. The product is trademarked under the names ‘GLP’ and ‘German Light Products’ and is registered in Germany, the United States of America, and other countries. The product has multiple mounting options and can be secured with a safety cable. It can be installed on a rigging truss or any similar structure or can be placed on a horizontal surface. The fixture requires AC mains power and can be connected to DMX data for control. The product has a control menu with an onboard display. It also has a cleaning and service section in the user manual.

Product Usage Instructions

Installation
The Fusion EXO Spot 30 can be installed using the permitted mounting options mentioned in the user manual. It can be secured with a safety cable and installed on a rigging truss or any similar structure. It can also be placed on a horizontal surface. Please refer to section 4 of the user manual for detailed installation instructions.

AC mains power
The fixture requires AC mains power and comes with included items for connecting to power. Please refer to section 5 of the user manual for detailed instructions on connecting to power and installing power connectors.

Connecting to DMX data
The Fusion EXO Spot 30 can be connected to DMX data for control. Please refer to section 6 of the user manual for detailed instructions on connecting to DMX data.

Starting and stopping operation
The product can be started and stopped using the control menus and onboard display. Please refer to section 7 of the user manual for detailed instructions on starting and stopping operation.

Control menus and onboard display
The product has a control menu with an onboard display. Please refer to section 9 of the user manual for detailed information on the control menus and display options.

Service
The product has a cleaning and service section in the user manual. Please refer to section 13 of the user manual for detailed instructions on cleaning and GLP service and support.

User Manual

Fusion EXO Spot 30
Software version V1.0.00

GLP® Fusion EXO Spot 30 User Manual ­ Revision D
This document covers fixture software version V1.0.00
© 2020 – 2022 German Light Products GmbH. All rights reserved.
The marks GLP’ andGerman Light Products’ are trademarks registered as the property of German Light Products GmbH in Germany, in the United States of America and in other countries.
The information contained in this document is subject to change without notice. German Light Products GmbH and all affiliated companies disclaim liability for any injury, damage, direct or indirect loss, consequential or economic loss or any other loss occasioned by the use of, inability to use or reliance on the information contained in this document.
Manufacturer’s head office: German Light Products GmbH (GLP), Industriestrasse 2, 76307 Karlsbad, Germany Tel (Germany): +49 7248 92719 – 0
Service & Support EMEA: GLP, Industriestrasse 2, 76307 Karlsbad, Germany Tel. (Germany): +49 7248 9271955 Email: support@glp.de www.glp.de
Service & Support USA: GLP USA, 1145 Arroyo St., Ste. A, 91340 San Fernando, California Tel (USA): +1 818 767 8899 Support (US): info@germanlightproducts.com www.germanlightproducts.com

German Light Products®

Safety

1. Safety
Key to symbols
The following symbols are used in the Fusion EXO Spot 30 lighting fixture’s user documentation:

Warning! Safety hazard. Risk of severe injury or death.
Warning! See user manual for important safety information.

Warning! Hazardous voltage. Risk of lethal or severe electric shock.
Warning! Fire hazard.

Warning! Risk of eye injury.

General safety information
Read this manual carefully before installing, using or servicing the Fusion EXO Spot 30 lighting fixture.
If you have any doubts or questions about how to use the fixture safely, contact your GLP® supplier for assistance. Your GLP supplier will be happy to help.
The user documentation for GLP Fusion EXO Spot 30 lighting fixtures consists of:
This document, the EXO Spot 30 User Manual, supplied with the fixture and available for download from www.glp.de. The User Manual contains important safety information and installation instructions that the installer and user must read.
The EXO Spot 30 DMX Channel Index, available for download from www.glp.de. The Channel Index is a separate guide to the DMX control channel layout and DMX commands available.
All documents are available for download from www.glp.de.
The Fusion EXO Spot 30 is intended for use by experienced professionals with the knowledge and skills to set up, operate, and maintain high-powered, remotely controlled lighting equipment safely and efficiently. These operations require expertise that may not be provided in this Manual or in the User Manual.
Respect all warnings and directions given in the fixture’s user documentation and on the fixture. Read the user documentation and familiarize yourself with the safety precautions it contains before installing or using the fixture. GLP and affiliated

EXO Spot 30 User Manual Rev. D

5

www.glp.de

Safety

companies will take no responsibility for damage or injury resulting from disregard for the information in the user documentation.
Check the GLP website at www.glp.de and make sure that you have the latest version of this manual. Check the fixture software version indicated on page 2 of this manual and then use the fixture’s control panel to check the version installed in the fixture. If the versions are not the same, this manual may still cover the fixture, because software updates do not always affect the way you use the fixture. However, it is possible that this manual does not match the fixture perfectly. Software release notes can help clarify this question. You can consult software release notes and download the correct version of this manual on the GLP website if necessary.
Make all user documentation available to all installers and operators. Save this document for future reference.
If you have any questions about the safe operation of the fixture, please contact an authorized GLP distributor (see list of distributors at www.glp.de).
Use the fixture only as directed in this manual. Observe all markings in this manual and on the fixture.
Refer all repairs and any service operation not described in this manual to a technician authorized by GLP.
The light source in this fixture must not be changed by the end user.
Read and follow the user documentation for all additional equipment.

Electrical safety
Do not allow the fixture to become immersed. Do not expose the fixture to highpressure water projections.
Keep any unused connectors on the fixture sealed with their protective caps at all times, both when the fixture is in use and when not in use.
Use only a source of AC mains power that complies with local building and electrical codes and has both overload and ground fault (earth fault) protection.
Ensure that the fixture is electrically connected to ground (earth).
Disconnect the fixture from AC mains power before carrying out any installation or maintenance work and when the fixture is not in use.
Disconnect the fixture from power immediately if any seal, cover, cable, connector or other component is damaged, defective, deformed or showing signs of overheating. Do not reapply power until the fixture has been repaired and made safe by a technician authorized by GLP.
Check that all power distribution equipment, cables and connectors are in perfect condition, rated for the electrical requirements of all connected devices, suitable for their application and suitable for the installation environment.

6

EXO Spot 30 User Manual Rev. D

German Light Products®

Safety

Use only Neutrik PowerCON TRUE1 cable connectors for AC mains power input at the fixture’s Mains IN connector and for relaying AC mains power from one fixture’s Mains OUT (Thru) connector to another fixture’s Mains IN connector.
Use minimum 14 AWG or 1.5 mm2 power input and relay cables that are minimum 16 A-rated and temperature-rated to suit the application. In the USA and Canada the cables must be UL-listed, type SJT or equivalent. In the EU the cables must be type H05VV-F or equivalent.
Do not connect devices to power in a chain if the total maximum current draw of all the devices in the chain when added together will exceed the current rating of any cable or connector used at any point in the chain. The supplied power input cable is rated as follows:
– US power cable: 16 A, 14 AWG, UL-listed, E304117, SJT, 4.9 ft.
– EU power cable: 16 A, 1.5 mm², H07RN-F, 1.5 m.
Do not connect more than six (6) Fusion EXO Spot 30 fixtures to power in a chain at 100-120 V, 60 Hz.
Do not connect more than twelve (12) Fusion EXO Spot 30 fixtures to power in a chain at 200-240 V, 50 Hz.
The voltage and frequency at the Mains OUT socket are the same as the voltage and frequency applied to the Mains IN socket. Only connect devices to the Mains Out socket that accept this voltage and frequency.
Fusion EXO Spot 30 fixtures do not have a user-replaceable fuse. If you suspect that a fuse has blown, disconnect the fixture from power and send it to a technician authorized by GLP for repair.

Fire safety and protection from burns
Do not operate the fixture if the ambient temperature (Ta) exceeds 40° C / 104° F.
The surface of the fixture’s casing can reach up to 90° C / 194° F during operation. Avoid contact by persons and materials. Do not install the fixture in a location where there is a risk of accidental contact. Allow the fixture to cool for at least 20 minutes before handling
Keep the fixture well away from flammable materials.
Keep all combustible materials (e.g. fabric, wood, paper) at least 0.5 m / 20 in. away from the fixture.
Ensure that there is free and unobstructed airflow around the fixture.
Do not illuminate surfaces within 0.5 m / 20 in. of the fixture. The light output from the fixture is powerful enough to cause burns or fire in illuminated objects at very close range.
Do not stick filters, masks or other materials onto the fixture. Do not block the light output in any way. The front surface becomes hot during operation and can melt or

EXO Spot 30 User Manual Rev. D

7

www.glp.de

Safety

ignite objects that are in contact with the surface. Ensure that the front surface Is clean and unobstructed at all times in order to prevent a fire hazard and damage to the fixture.
The fixture’s optical components can focus the sun’s rays, creating a risk of fire and damage. Do not expose the front of the fixture to sunlight or any other intense light source, even from an angle.

Eye safety
The EXO Spot 30 is classified as a Risk Group 3 lighting fixture according to EN 62471. Possibly hazardous radiation emitted. Do not stare into the light output from the fixture. May be harmful to the eyes.
Do not look at the fixture’s light output with optical instruments or any device that may concentrate the light output.
Make sure that persons near to or working on the fixture are not looking directly into the light output when the fixture lights up suddenly. This can happen when power is applied, when the fixture receives a DMX signal, or when certain control menu items are selected.
The warning below is printed on the fixture. If the warning becomes impossible to read, replace it with a label reproduced from this illustration:

Provide well-lit conditions to reduce the pupil diameter of anyone working on or near the fixture.

Strobe safety
Flashing light, particularly at 5 – 30 Hz, may cause seizures in persons with photosensitive epilepsy. Do not use strobe effects for extended periods.
Comply with local regulations on the use of strobe lighting and notify the public in advance with highly visible warning signs when strobe effects are used.
If a seizure occurs, stop using strobe effects. Seek professional medical help. Note the time that the seizure starts and finishes. Call emergency medical help urgently if

8

EXO Spot 30 User Manual Rev. D

German Light Products®

Safety

the seizure lasts more than five minutes, if it is the person’s first seizure, or if the person is injured. While waiting for help to arrive, protect the affected person from injuring themselves on hard or sharp objects. If necessary, move the person to a safe place. Lay them on their side with their head supported to prevent it from hitting the floor. Loosen any tight clothing around their neck. Do not use force to hold the person or restrict their movements. Do not put anything in their mouth, including your fingers.

Installation safety and protection from personal injury
Installation must be performed by qualified personnel only and carried out in accordance with all locally applicable regulations such as DIN VDE 0711-217.
The fixture is not portable when installed.
Ensure that the supporting structure and installation hardware used can hold at least ten times the weight of the load that they support.
Fasten the fixture to a structure or surface only as directed in this manual and only with hardware that is specifically designed and rated for its purpose. Do not use a safety cable as the primary means of support. Check that installation hardware is in perfect condition. Fasteners must be steel grade 8.8 strength or better. Rigging clamps must be half-coupler type that completely encircle the rigging truss chord.
If the fixture is installed in a location where it may cause injury or damage if it falls, install as directed in this manual a safety cable or similar secondary attachment that will hold the fixture if a primary attachment fails. The secondary attachment must be approved by an official body such as TÜV as a safety attachment for the weight that it secures, it must comply with EN 60598-2-17 Section 17.6.6, and it must be able to support a static suspended load that is ten times the weight that it secures.
If the fixture is installed in a location where it may be exposed to forces such as wind pressure, vibration or movement, make sure that the installation can withstand these forces. Monitor weather forecasts constantly. Take down the installation immediately if there is any risk of weather conditions that could destabilize the installation.
Check that all covers and items of rigging hardware are secure before using the fixture. Do not operate the fixture with missing or damaged covers, shields or any optical component.
Restrict access below the work area and work from a stable platform whenever installing, servicing or moving the fixture.
If the fixture becomes damaged, stop using it immediately and disconnect it from power. Do not attempt to use a fixture that is obviously damaged.
Do not modify the fixture in any way not described in its user documentation.
Install genuine GLP parts only.

EXO Spot 30 User Manual Rev. D

9

www.glp.de

Avoiding damage to the fixture

2. Avoiding damage to the fixture
Important! Follow the directions in this section carefully, or the fixture may suffer damage that is not covered by the product warranty.
General precautions
Do not drop the fixture or expose it to mechanical stress. Protect the onboard LCD display and control panel from shocks, or they may suffer damage that is not covered by the product warranty. Do not expose the fixture to heat (from other lighting fixtures for example). Clean optical components only as directed. Oils, solvents, and other chemicals commonly used for cleaning can damage the lens coatings and surfaces. Use only original spare parts. Do not make any structural modifications to the fixture or you will void the product warranty.
Avoiding damage from light sources and heat
Do not point the front of the fixture towards the sun or other strong light sources. Strong light can cause internal damage to the fixture, melting components or starting an internal fire within seconds.

Figure 1. Avoiding damage from light sources
Damage can occur whether the fixture is powered on or off. See Figure 1. Damage can also occur if the light hits the front of the fixture at an angle: the fixture does not need to be pointing directly at the sun or other light source.
To avoid problems from strong light sources:
Do not expose the front of the fixture to sunlight or any other strong light source. In outdoor applications during daylight, make sure that the front face of the fixture is
shielded or points away from the sun, even when not in use.
Do not aim other high-powered beam lights directly at the fixture. Do not operate the fixture in ambient temperatures above 40° C / 104° F. Allow free airflow around the fixture.

10

EXO Spot 30 User Manual Rev. D

German Light Products® Avoiding damage to the fixture
IP rating
EXO Spot 30 fixtures are IP65-rated:
IP stands for Ingress (entry into the fixture) Protection. The first figure 6 in the rating means that fixtures are protected against the entry of
dust and airborne particles.
The second figure 5 in the rating means that fixtures are protected against the entry of rain and water projections from all angles. Fixtures are not protected against immersion in water and they are not protected against high- pressure water jets.
Avoiding damage from water and humidity
Do not install EXO Spot 30 fixtures in a location where water can pool around the fixture or allow EXO Spot 30 fixtures to become submerged in any other way. Do not aim low- or high-pressure water jets at fixtures.
Keep all unused connectors on the fixture sealed with their protective caps, both when the fixture is being used and when it is not in use.
In outdoor and high-humidity environments, use IP65-rated power and data connectors and cable (an IP65 rating means that the item is protected against the entry of water from rain, projections and low-pressure jets as well as the entry of dust). When assembling connectors and installing them on cable, follow the manufacturer’s instructions (see www.neutrik.com) and ensure that an IP65 rating is maintained for the complete assembly. Use only the following cable connectors:
– IP65-rated 5-pin XLR connectors for data IN and OUT (THRU)
– Neutrik powerCON TRUE1 NAC3FX-W for Power IN
– Neutrik powerCON TRUE1 NAC3MX-W for Power OUT (THRU).
Apply a dielectric grease (available from electrical suppliers) to connector terminals and caps to prevent corrosion and/or electrical short circuits.
Make sure that cables open into dry areas or sealed junction boxes. Moisture can be drawn along cables by capillary action or pressure variations resulting from thermal expansion.
See drawing on right. Arrange cables so that they arrive at connectors from below. Make sure that it is impossible for water to flow down cables and accumulate at connectors. If necessary, provide extra cable slack and create `drip loops’ before connectors.
Create loose cable bends only. Do not subject connections to bending forces or allow connections to bear the weight of long lengths of cable.

EXO Spot 30 User Manual Rev. D

11

www.glp.de

Avoiding damage to the fixture

Avoiding damage from dust and airborne particles
Carry out regular visual inspections of the fixture to make sure that there is no accumulation of dirt, especially on the front of the fixture.
If cleaning is necessary, follow the instructions in `Service’ on page 38.
Transportation and storage
Transport the fixture in its original packaging or a suitably designed flight case to protect it from damage caused by shocks during transportation.
Release the tilt lock and support the fixture’s head with the original packaging inserts or flight case inserts during transportation.
Store the fixture in a dry location when not in use.
GLP Service and Support
Contact information for the nearest GLP Service and Support is available online at www.glp.de/en/service, by email at info@glp.de, or by telephone at the following numbers: GLP Germany: +49 (7248) 927 19-55 GLP N. America: +1 818 767-8899 GLP UK: +44 1392 690140 GLP Asia: +852 (3151) 7730 GLP Nordic: +46 737 57 11 40

12

EXO Spot 30 User Manual Rev. D

German Light Products®

EXO Spot 30 overview

3. EXO Spot 30 overview
The Fusion EXO Spot 30 from GLP is a powerful LED-based profile spot fixture with fast pan and tilt, CMY color mixing, six fixed colors on three separate wheels, and six rotating / eight fixed gobos on two wheels. A rotating prism, variable frost, variable beam angle (zoom) are also provided.
The fixture can be controlled by DMX or by settings on its built in color LCD control panel. An optional wireless DMX module can be fitted to enable LumenRadio wireless control. The fixture has a built-in battery to allow the display to be operated for setup before mains power is connected.
The EXO Spot 30 can be used indoors in permanent and temporary installations. Its rugged construction and IP65 rating mean that it can also be used outdoors in temporary installations if precautions are taken to prevent immersion in water and damage from direct sunlight. It can stand on a horizontal surface or be suspended from a suitable structure as described in Section 4.
The EXO Spot 30 is not suitable for household use, for use in any location where unattended children have access to it, or for use in permanent outdoor installations.

EXO Spot 30 User Manual Rev. D

13

www.glp.de

EXO Spot 30 overview

Figure 2. EXO Spot 30 overview

1 ­ Output lens 2 ­ Head 3 ­ Tilt lock 4 ­ Yoke 5 ­ Control panel 6 ­ Base 7 ­ Rubber feet

8 ­ Wireless indicator 9 ­ Battery button 10 ­ PowerCON TRUE1 input 11 ­ Mode / Esc button 12 ­ Up button 13 ­ Down button 14 ­ Enter button 15 ­ Optional wireless antenna 16 ­ 5 pin XLR DMX input 17 ­ 5 pin XLR DMX link out 18 ­ Vent valve 19 ­ PowerCON TRUE1 link out

14

EXO Spot 30 User Manual Rev. D

German Light Products®

Installation

4. Installation
Warning! Read `Safety’ starting on page 5 for important safety information that you must understand before you install or operate the fixture. Install EXO Spot 30 fixtures only as described in this chapter, or you may create an installation that is unsafe.
Install the fixture at least 0.5 m / 20 in. away from combustible materials (wood, textiles, paper, etc.), 0.5 m / 20 in. away from any surface that will be illuminated, and a safe distance away from any flammable materials (volatile spirits, etc.).
It is the installer’s responsibility to provide a stable, secure supporting structure that is suitable for the environment and application and that meets all applicable codes and legal requirements. Note the requirement to secure lighting fixtures with safety cables in temporary installations.
Permitted mounting options
An EXO Spot 30 fixture may be installed in one of the following ways:
1. Fastened to a rigging truss or similar structure at any angle by means of truss couplers or other clamps fixed to the two Omega brackets which attach to the half-turn couplers on the underside of the base.
2. Standing upright on the base on a horizontal surface.
Securing fixtures with a safety cable
In temporary installations, if a fixture can cause injury or damage if it falls you must secure it with a secondary attachment such as a safety cable that will hold it if the primary means of attachment fails. The safety cable must be approved for the weight that it secures. In multiple installations, each fixture must have its own safety cable.

EXO Spot 30 User Manual Rev. D

15

www.glp.de

Installation

To secure an EXO Spot 30 fixture with a safety cable:

Figure 3. Safety cable attachment
1. Loop a safety cable around a secure anchoring point such as a truss beam or fixed structure so that it will catch the fixture if a rigging clamp fails. Take up as much slack as possible in the safety cable (by looping it more than once around the bar, for example). 2. See Figure 3 and Figure 4. Fasten the safety cable through the slot “B” on the underside of the fixture base. Check that the fixture is now secured.
Installing on a rigging truss or similar structure
You can suspend an EXO Spot 30 fixture from a rigging truss or pipe using suitable clamps attached to the Omega Brackets supplied with the EXO Spot 30. If you are going to install the fixture hanging vertically downwards from a horizontal rigging truss or pipe, you can fasten it to the truss using G-clamps. If you are going to install the fixture in any other orientation, you must use half-coupler clamps that completely surround the truss chord or pipe.

16

EXO Spot 30 User Manual Rev. D

German Light Products®

Installation

Figure 4. Omega bracket fasteners
1. Attach suitable clamps to the Omega brackets. 2. Line up the fasteners of the Omega bracket with the holes “A” in the base of the EXO Spot 30 as shown in Figure 4. The brackets may be installed either way round so the cabling is in line with the bar or at right angles to it. 3. Lock the Omega brackets onto the EXO Spot 30 by turning the fasteners through 90 degrees. 4. Attach the clamp to the truss or structure. Ensure that the head and yoke of the fixture will not collide with any fixed objects as the fixture moves. Ensure that the fixture has sufficient clearance to any adjacent surfaces or objects. 5. Secure the fixture with a safety cable through slots “B” as described in the previous section.
Standing on a horizontal surface
To install an EXO Spot 30 fixture on a horizontal surface: 1. Check that the surface is secure and can safely hold the weight of the fixture plus all hardware and cables. 2. Stand the fixture firmly on the rubber feet fitted to the base of the unit. Ensure that the head and yoke of the fixture will not collide with any fixed objects as the fixture moves. Ensure that the fixture has sufficient clearance to any adjacent surfaces or objects.

EXO Spot 30 User Manual Rev. D

17

www.glp.de

AC mains power

5. AC mains power
Warning! Read Safety’ starting on page 5 for important safety information that you must understand before you install or operate the fixture. Check that all cables and connectors are suitable for the installation environment and application (see recommendations inAvoiding damage to the fixture’ on page 10). Use H07 RN-F 3 x 2.5mm / SJT 12 AWG cables with original Neutrik powerCON TRUE1 connectors to supply power to fixtures.
Line up the keyways in connectors carefully. Do not try to insert or twist a connector if it feels excessively stiff. Resistance to insertion or twisting is a sign that connectors may be incorrectly lined up.
Keep connectors sealed with their rubber caps at all times when not in use.
Included items
The EXO Spot 30 is supplied with a power cord with Neutrik powerCON TRUE1 connector.
Connecting to power
The AC mains power supply must include a connection to ground / protective earth. It must be protected against ground / earth leakage and overload. The fixture’s internal auto-sensing power supply accepts AC power at 100-240 V, 50/60 Hz. Do not connect the fixture to power at any other voltage or to an external dimmer.
The EXO Spot 30 does not have a power ON/OFF switch. Power is applied to the fixture as soon as the power cable becomes live.
The EXO Spot 30 has a 3-conductor Neutrik powerCON TRUE1 Mains IN power input socket that accepts AC power from a TRUE1 female cable connector. Although TRUE1 connectors support hot plugging, it is still good practice to shut down power to power cables before connecting them to fixtures.
To connect the fixture to power:
1. If convenient, shut down power to the power input cable.
2. Note the position of the keys and keyways on the TRUE1 power cable connector and Mains IN socket and align them with each other. Insert the cable connector into the socket and twist clockwise to lock. Do not use force. If the connector feels excessively stiff, remove it and check again that it is lined up correctly.
3. Before applying power to the power cable, check that nobody is looking directly into the front of the fixture.
To disconnect the fixture from power, pull the latch on the cable connector outwards to release it, then twist the connector counterclockwise and pull to remove it from the socket.

18

EXO Spot 30 User Manual Rev. D

German Light Products®

AC mains power

Installing power connectors
If you intend to draw power from convenience receptacles / consumer mains power sockets, it is possible to install a suitable cord cap / power plug on the supplied power cord / input cable. If you do this, check that the cord cap / plug is rated minimum 250 V, 16 A, that it has a connection to ground / earth and that it has an integral cable grip. Follow the cord cap / plug manufacturer’s assembly instructions.
If you need to install a Neutrik powerCON TRUE1 connector on a power cable, follow the instructions given in the Support area of the Neutrik website at www.neutrik.com.
Respect the color coding used in the supplied power cable and in your local mains power wiring system. US and EU systems use the color coding shown below:

US system EU system

Live or L Black Brown

Neutral or N White Blue

Ground / Earth or Green
Yellow/green

Connecting multiple fixtures to power in a chain
You can connect fixtures to power in a daisy-chain to simplify your power circuit layout.
EXO Spot 30 fixtures have 2.5 mm2 internal wiring from Power IN to Power THRU connectors.
Warning! Do not connect more than six (6) EXO Spot 30 fixtures in total to power in one chain at 100-120 V, 60 Hz. Do not connect more than twelve (12) EXO Spot 30 fixtures in total to power in one chain at 200-240 V, 50 Hz.
The power input cable supplied with the fixture is rated 16 A maximum. Add together the maximum current draw ratings of all the devices that you intend to connect to power in a daisy chain and do not create a chain with a total maximum current draw of more than 16 A, or you will create a risk of fire and electric shock.
To connect fixtures to power in a chain:
1. Obtain power relay cables that have male and female Neutrik powerCON TRUE1 connectors. Cables must be minimum 14 AWG or 1.5mm2, rated minimum 16 A and suitable for the environment and application.
2. Connect the power input cable to the Mains IN socket of the first fixture as described under `Connecting to power’ on page 18.
3. Connect a relay cable to the Mains OUT / THRU socket of the first fixture and to the Mains IN socket of the second fixture.
4. If you are using 100-120 V, 60 Hz AC mains power you can continue linking EXO Beam fixtures Mains OUT / THRU socket to Mains IN socket until the chain contains a maximum of six (6) fixtures in total. If you are using 200-240 V, 50 Hz AC mains power you can continue connecting fixtures Mains OUT to Mains IN until the chain contains a maximum of twelve (12) fixtures total.

EXO Spot 30 User Manual Rev. D

19

www.glp.de

Connecting to DMX data

Connecting to DMX data

Check that all cables and connectors are suitable for the installation environment and application (see recommendations in `Avoiding damage to the fixture’ on page 10). Use digital 110 Ohm DMX cable with IP65 5-pin XLR connectors to supply DMX data to fixtures. Keep connectors sealed with their rubber caps at all times when not in use. The EXO Spot 30 has two 5-pin XLR sockets for IN and THRU connections to a DMX data link. EXO Spot 30 fixtures support the USITT DMX 512A signal protocol. They also support RDM (Remote Device Management). The 5-pin XLR connectors use standard pin allocations:
1 Signal Ground 2 Data ­ 3 Data + 4 Not used 5 Not used
The DMX cable should start at the console and be daisy-chained through each fixture to be controlled using the DMX input and DMX link out connectors. If you need to split the DMX cable, use a powered DMX splitter. If you would like advice with planning and installing a DMX link, your GLP supplier will be happy to provide assistance.

20

EXO Spot 30 User Manual Rev. D

German Light Products® Starting and stopping operation

Starting and stopping operation

Warning! Before you apply power to the fixture or operate it after a blackout, make sure that nobody is looking directly into the front of the fixture.
The EXO Spot 30’s TRUE1 mains power input connector supports hot-plugging, and connecting and disconnecting a live power cable is an option, especially if you need to shut down power urgently, but it is still good practice to shut down power to the AC mains power circuit before connecting and disconnecting power cables. To start operation, check that nobody is looking into the front of the fixture, then apply power to the AC mains power circuit. To stop operation, shut down power to the AC mains power circuit.

EXO Spot 30 User Manual Rev. D

21

www.glp.de

Features

8. Features
The EXO Spot 30 unit has the following features:
Position
Pan rotation 540°, Tilt rotation 258° with 16 bit resolution. The fixture will automatically reposition if knocked ­ this option can be disabled from the menu. The Pan and Tilt movements can be inverted using the menu.
Dimming
16-bit dimming control is provided. You can select from two dimming curves using the control panel or the Control / Settings DMX channel, see Figure 5:

Figure 5. Dimming curves Linear sets dimming so that it appears to increase and decrease evenly throughout
the dimming range. Soft gives finer control at low light levels and coarser control at high light levels. The default setting is Soft.
Color wheels
Color can be controlled either by variable Cyan, Magenta, Yellow control channels (810), or fixed color filters can be selected using Color 1/Cyan, Color 2/Magenta, Color 3/Yellow control channels (5-7). To set a fixed color you must have the corresponding variable color channel set to zero to set Color 1 on channel 5 you must set Cyan on channel 8 to zero, to set Color 2 on channel 6 you must set Magenta on channel 9 to zero, to set Color 3 on channel 7 you must set Yellow on channel 10 to zero,

22

EXO Spot 30 User Manual Rev. D

German Light Products®

Features

Internally the fixture has three color wheels each with 4 colors including open white and a variable Cyan, Magenta or Yellow segment.

Figure 6. Color Wheels

EXO Spot 30 User Manual Rev. D

23

www.glp.de

Features

Gobo wheels
The EXO Spot 30 has two gobo wheels. Wheel 1 has 9 positions including open and the gobos are fixed (non-rotating).

Figure 7. Gobo Wheel 1
Wheel 2 has seven positions including open and these gobos are rotatable and indexable.

Figure 8. Gobo Wheel 2

24

EXO Spot 30 User Manual Rev. D

German Light Products®

Features

Strobe / shutter
A variety of strobing and fading effects can be produced by the fixture.
Prism
A three segment prism allows beam splitting effects. The prism can be independently inserted in the beam path or removed, and can be continuously rotated in either direction or set to an indexed position.
Frost
A variable amount of frost / diffusion can be added to the light beam
Focus
Variable focus allows you to focus the output on Gobo wheel 1, Gobo wheel 2 or create gobo morph effects by moving focus between two gobos.
Zoom
The beam size can be controlled between 7 degrees and 30 degrees. A menu option allows you to reverse the operation of the zoom control.

EXO Spot 30 User Manual Rev. D

25

www.glp.de

Features

Behavior when the fixture is not receiving a DMX signal
You can set the fixture to react in three different ways if no DMX signal is present (if the fixture is being controlled by DMX but the DMX signal stops, or if you apply power to the fixture when no DMX signal is present):
Blackout sets the fixture to black out. This is the default setting.
Hold sets the fixture to continue obeying the last DMX values it received. If no DMX signal was being received, the fixture will black out.
Preset Scene sets the fixture to output a preset scene which you have previously captured from an incoming DMX state using the Manual Control > Capture Scene menu option. You can also manually set the control values (or edit the captured values) using the attribute settings in the Manual Control menu.
All these settings are available via DMX on the Control / Settings channel and in the fixture’s control panel.

26

EXO Spot 30 User Manual Rev. D

German Light Products®Control menus and onboard display
9. Control menus and onboard display
Warning! DMX control is disabled when the control menus are active. Be prepared for the fixture to emit strong light as soon as you exit the control menus.
The control panel and onboard LCD display provide access to user settings, readouts and utilities.

Figure 9. Onboard display
The four control buttons have the following functions: MODE/ESC: Activate the menus or go back one level towards the top of the menu. UP: Scroll up or increase a number. DOWN: Scroll down or reduce a number. ENTER: Activate the control panel if it is in sleep mode. Then enter a menu, select a setting or implement a command.
When you apply power to the fixture, it boots up. After it has booted, the panel displays the default screen. The Battery button is used to power up the control panel for setup before mains is connected to the unit. Battery mode can be disabled in the menu. The W-DMX indicator shows when wireless DMX is being received, if the optional wireless module has been fitted.

EXO Spot 30 User Manual Rev. D

27

www.glp.de

Control menus and onboard display

DMX control is disabled when the control menus are active.
Display options
The illuminated LCD display lets you change fixture settings. The display has a battery backup so that you can change the settings before mains is connected to the fixture. See Chapter 9 for more details. Using the Control / Settings DMX channel or the fixture’s control panel you can: Set display modes using the Fixture Settings > Display Mode option:
– On: The display stays on constantly. This setting can be useful when you are configuring or servicing the fixture.
– Auto: The display will automatically switch off after a few seconds even if the fixture is not receiving a valid control signal or if it has detected an error.
Invert the display using the Fixture Settings > Display Orientation option, so it is easier to read if the fixture is hanging upside down.
Display Locking
On the Fixture Settings > Lock menu, you can configure the display to lock after a period of time to prevent accidental changes to the options.
You can set a custom lock code using the Fixture Settings > Lock > Set Passcode option. If you do not set a custom code, the default code is 0000.
Manual Control
Using the Manual Control menu you can set fixed values to the fixture’s control channels, as if it was in DMX control mode 1. This is useful when testing.
LED PWM frequency
The LEDs in the unit are dimmed using Pulse Width Modulation (PWM) which can sometimes cause flickering on cameras. The Fixture Settings > PWM option allows you to select different frequencies for the PWM to fix such issues. The higher frequencies may cause reduced dimming performance.
Fan control
The fixture has internal cooling fans. In a noise critical situation you can slow these down using the Fixture Settings > Fan Mode option. The normal setting is Regulated which will adjust the fan speed automatically. If you set the option to Low the fan speed is kept slow but this may result in the fixture overheating and reducing its output.
The fixture has an additional fan near the lens to clear condensation. You can control how this fan works using the Fixture Settings > Defog option.
Fixture information
The Information menu in the control panel gives access to items of information from the fixture’s sensors and memory. You can check temperature sensor readouts, see total operating hours counters, and see software version number, for example.

28

EXO Spot 30 User Manual Rev. D

German Light Products®Control menus and onboard display
Pan disable / Tilt disable
These options allow you to disable the startup reset movements or disable the drive of the pan and/or tilt motors. The options are
– Off: Normal motor control – Reset Disabled: The fixture will not do its power on reset sequence on this motor but
the motor is still controlled. This can be used when a fixture is mounted in a confined space and would collide with an obstruction if it did the reset sequence. – Current Disabled: The motor drive function is completely disabled. This is mostly used for service or diagnostics.
Preset settings and factory defaults
You can store three different versions of option settings using the Service > Service Advanced > Save Settings menu and load them using the Load Settings > Preset 1-2-3 options. These allow you to quickly set up the fixture in a particular configuration. Settings are stored after a power off/on cycle and after a reset. Two options are available in the fixture’s control panel for deleting multiple custom settings and restoring defaults:
– Service > Default Settings reloads all the fixture’s factory default settings except DMX address, DMX mode, captured scene, preset settings and offset values. This option returns the fixture to baseline settings without affecting its basic configuration in an installation.
– Service > Service Advanced > Factory Backup reloads all the fixture’s factory default settings including DMX address, DMX mode, and erases all storage. This option reinitializes the fixture completely and returns to its state when it left the factory.

EXO Spot 30 User Manual Rev. D

29

www.glp.de

Control menu layout

10. Control menu layout

Menus
DMX ADDRESS CONTROL MODE CONTROL PROTOCOL
FIXTURE SETTINGS

1 – 512
Standard ­ 24 channels DMX WIRELESS Pan Invert Tilt Invert Position Feedback
Pan Disabled
Tilt Disabled Zoom Invert Dimmer Curve No Signal
Capture Scene
PWM Display Mode Display Orientation
Max Temperature

Fan Mode Load Settings Lock Defog

Battery

Reboot

MANUAL CONTROL

Manual function control (DMX Mode 1)

Notes

Enter DMX address

Select DMX control mode

Off / On Off / On
Off / On Off / Reset Disabled / Current Disabled Off / Reset Disabled / Current Disabled Off / On Soft (Gamma) / Linear Blackout / Hold / run Captured Scene Press ENTER to capture scene 600 Hz / 2200 Hz / 3000 Hz / 4800 Hz / 9600 Hz / 25000 Hz Auto / On / Off Normal / Upside Down
60 ­ 90C / 140-194F
Regulated / High / Medium / Low Preset 1 / Preset 2 / Preset 3
Off / On /. Set Passcode
Off / On / Quick
On / Off
Pan Coarse 0-255 Pan Fine 0-255 Tilt Coarse 0-255 Tilt Fine 0-255 Color 1 Cyan 0-255 Color 2 Magenta 0-255 Color 3 Yellow 0-255 Cyan 0-255 Magenta 0-255

Wired DMX control Wireless DMX control (optional module) Invert Pan movement Invert Tilt movement Reposition fixture if knocked
Disable motor drive for service
Inverts Zoom movement Dimming curve Action when no DMX signal
Store scene for no signal
Frequency of LED dimming
Display blanking Display reversing Sets overheat temperature where shutdown will occur
Set fan speed control
Press ENTER for 3 sec to confirm Lock the control panel Settings for lens defogging fan Disable the battery operation of the control panel Press ENTER for 3 sec to confirm
These values can be set manually or from a DMX state using Capture Scene option

30

EXO Spot 30 User Manual Rev. D

German Light Products®

Control menu layout

INFORMATIO N
SERVICE
FACTORY MENU

Yellow 0-255 Gobo Wheel 1 0-255 Gobo Wheel 2 0-255 Gobo 2 rotation coarse 0255 Gobo 2 rotation fine 0-255 Shutter 0-255 Dimmer Coarse 0-255 Dimmer Fine 0-255 Frost 0-255 Prism 0-255 Prism rotation 0-255 Focus coarse 0-255 Focus fine 0-255 Zoom 0-255 Control 0-255

Capture Scene

Firmware Version Fixture Details

ver x.x Serial … xx / RDM … xx

Device Life
DMX Link Status
Temperatures Fan Speeds Error Log
Test All
Test Pan only Test Tilt only Test LED only Test Zoom only Default Settings Service Advanced

Total / User Refresh Rate (Hz) / Frame Length / Mode Length xxx… Fan1 … Xxx
Running
Running Running Running Running
See below for menu

This menu is for use by authorized service technicians only

Press ENTER for 3 sec to capture incoming DMX state Fixture firmware version Show fixture serial, RDM unique ID Shows power cycles, Power Hours, LED Hours Details of DMX signal Unit temperatures
Press Enter to start test, Menu or Enter to stop
See Note 1 below Hold Enter for 6 sec to enter this menu

Note 1: Default Setting will return all options to default except DMX address, Control Mode. It does not erase captured scene, preset settings or offset values
Default settings are written in BOLD type.

EXO Spot 30 User Manual Rev. D

31

www.glp.de

Control menu layout

Service Advanced menu

Hold down Enter for 6 seconds to access this menu.

Menus

Notes

Pan Disable Off/On

Tilt Disable

Off/On

Units

°C / °F

Offsets

Tilt

xxx

Zoom

xxx

Power Hours

Reset Counter

Power Cycles LED Hours Max Temperature

Save Settings
Factory Backup

Temperature Unit
Preset 1 Preset 2 Preset 3

See Note 2 below

Note 2: Factory backup will reset all options to default, erase captured scene, erase preset settings, erase offset values. User Hour counter and Temperature Unit will not be affected.

32

EXO Spot 30 User Manual Rev. D

German Light Products® DMX control mode overview

11. DMX control mode overview
The EXO Spot 30 has only one DMX control mode which uses the following DMX channels

DMX Mode 1: Standard
The EXO Spot 30 uses 23 DMX channels.
It provides 16-bit control of pan and tilt, 16-bit dimming and a shutter with strobe and ramp up/down effects. Control of the three color wheels, two gobo wheels, gobo rotation, zoom and the prism is provided.
You also have control of focus and a control / settings channel that lets you configure the feature and adjust settings remotely via DMX.

Mode 1 Compact
1 Pan 2 Pan fine 3 Tilt 4 Tilt fine 5 Color wheel 1 Cyan 6 Color wheel 2 Magenta 7 Color wheel 3 Yellow 8 Cyan 9 Magenta 10 Yellow 11 Gobo 1 12 Gobo 2 13 Gobo 2 index/rotate 14 Shutter 15 Dimmer coarse 16 Dimmer fine 17 Frost 18 Prism 19 Prism rotation 20 Focus coarse 21 Focus fine 22 Zoom 23 Control

EXO Spot 30 User Manual Rev. D

33

www.glp.de

DMX control channel layout tables

12. DMX control channel layout tables DMX Mode 1: Standard

24 DMX Channels

Channel

Command

1 Pan 2 Pan fine

Pan left­right

3 Tilt 4 Tilt fine

Tilt up­down

Open (Position 1)

Open/Dark Blue (Position 1 + 2)

Dark Blue (Position 2)

Dark Blue/Orange (Position 2 + 3)

Orange (Position 3)

Orange/Green (Position 3 + 4)

Green (Position 4)

Green/Cyan (Position 4 + 5)

5 Color 1 (Cyan) Cyan (Position 5) Indexing from Open over fixed

Colors and Cyan to Open

Color Bounce from Open over fixed

Colors to Cyan (full) and back, Fast-

Slow

Color Bounce Stop

Invert Color Bounce from Cyan (Full)

over fixed Colors to Open and back,

Slow-Fast

Open (Position 1)

Open/Blue (Position 1 + 2)

Blue (Position 2)

Blue/Red (Position 2 + 3)

Red (Position 3)

Red/Light Green (Position 3 + 4)

Light Green (Position 4)

Light Green/Magenta (Position 4 + 5)

6

Color 2 (Magenta)

Magenta (Position 5) Indexing from Open over fixed

Colors and Magenta to Open

Color Bounce from Open over fixed

Colors to Magenta (full) and back,

Fast-Slow

Color Bounce Stop

Invert Color Bounce from Magenta

(Full) over fixed Colors to Open and

back, Slow-Fast

Open (Position 1)

Open/CTO (Position 1 + 2)

CTO (Position 2)

7

Color 3 (Yellow)

CTO/Amber (Position 2 + 3) Amber (Position 3)

Amber/Dark Red (Position 3 + 4)

Dark Red (Position 4)

Dark Red/Yellow (Position 4 + 5)

DMX range
0 65535

Percent

0

100

Default DMX Fade
32767 Fade

0 65535 0

100 32767 Fade

0

3

0.0 1.2

4

7

1.6 2.7

8

11

3.1

4.3

12

15

4.7

5.9

16

19

6.3

7.5

20

23

7.8

9.0

24

27

9.4 10.6

28

31 11.0 12.2

32

35 12.5 13.7

0 Snap

36 169 14.1 66.3

170 214 66.7 83.9 215 215 84.3 84.3

216 255 84.7 100.0

0

3

0.0 1.2

4

7

1.6 2.7

8

11

3.1

4.3

12

15

4.7

5.9

16

19

6.3

7.5

20

23

7.8

9.0

24

27

9.4 10.6

28

31 11.0 12.2

32

35 12.5 13.7

0 Snap

36 169 14.1 66.3

170 214 66.7 83.9 215 215 84.3 84.3

216 255 84.7 100.0

0

3

0.0 1.2

4

7

1.6 2.7

8

11

3.1

4.3

12

15

4.7

5.9

16

19

6.3

7.5

0 Snap

20

23

7.8

9.0

24

27

9.4 10.6

28

31 11.0 12.2

34

EXO Spot 30 User Manual Rev. D

German Light Products® DMX control channel layout tables

Yellow (Position 5)

32

35 12.5 13.7

Indexing from Open over fixed

Colors and Yellow to Open

36 169 14.1 66.3

Color Bounce from Open over fixed

Colors to Yellow (full) and back, Fast-

Slow

170 214 66.7 83.9

Color Bounce Stop

215 215 84.3 84.3

Invert Color Bounce from Yellow

(Full) over fixed Colors to Open and

back, Slow-Fast

216 255 84.7 100.0

8 Cyan

Cyan color mixing (see note 1)

0

255

0

100

0 Fade

9 Magenta

Magenta color mixing (see note 1)

0

255

0

100

0 Fade

10 Yellow

Yellow color mixing (see note 1)

0

255

0

100

0 Fade

Open

0

7

0.0 2.7

Snap

Gobo 1

8

15

3.1

5.9

Snap

Gobo 2

16

23

6.3

9.0

Snap

Gobo 3

24

31

9.4 12.2

Snap

Gobo 4

32

39 12.5 15.3

Snap

Gobo 5

40

47 15.7 18.4

Snap

Gobo 6

48

55 18.8 21.6

Snap

Gobo 7

56

63 22.0 24.7

Snap

Gobo 8

64

71 25.1 27.8

Snap

Gobo 1 shaking

72

78 28.2 30.6

Snap

Gobo 2 shaking 11 Gobo wheel 1 Gobo 3 shaking

79

85 31.0 33.3

Snap

86

92 33.7 36.1

0 Snap

Gobo 4 shaking

93

99 36.5 38.8

Snap

Gobo 5 shaking

100 106 39.2 41.6

Snap

Gobo 6 shaking

107 113 42.0 44.3

Snap

Gobo 7 shaking

114 120 44.7 47.1

Snap

Gobo 8 shaking

121 127 47.5 49.8

Snap

Gobo wheel spin stop

128 128 50.2 50.2

Fade

Gobo wheel spin clockwise fast > slow

129 191 50.6 74.9

Fade

Gobo wheel spin stop

192 192 75.3 75.3

Fade

Gobo wheel spin counterclockwise slow > fast

193 255 75.7 100

Fade

Open

0

4

0.0 1.6

Snap

Gobo 1 indexed

5

9

2.0 3.5

Snap

Gobo 2 indexed

10

14

3.9

5.5

Snap

Gobo 3 indexed

15

19

5.9

7.5

Snap

Gobo 4 indexed

20

24

7.8

9.4

Snap

Gobo 5 indexed

25

29

9.8 11.4

Snap

Gobo 6 indexed

30

34 11.8 13.3

Snap

Gobo 1 rotate

35

39 13.7 15.3

Snap

Gobo 2 rotate

40

44 15.7 17.3

Snap

Gobo 3 rotate

45

49 17.6 19.2

Snap

Gobo 4 rotate

50

54 19.6 21.2

Snap

12 Gobo wheel 2 Gobo 5 rotate

55

59 21.6 23.1

0 Snap

Gobo 6 rotate

60

64 23.5 25.1

Snap

Gobo 1 shake and index

65

74 25.5 29.0

Snap

Gobo 2 shake and index

75

84 29.4 32.9

Snap

Gobo 3 shake and index

85

94 33.3 36.9

Snap

Gobo 4 shake and index

95 104 37.3 40.8

Snap

Gobo 5 shake and index

105 114 41.2 44.7

Snap

Gobo 6 shake and index

115 124 45.1 48.6

Snap

Gobo 1 shake and rotate

125 134 49.0 52.5

Snap

Gobo 2 shake and rotate

135 144 52.9 56.5

Snap

Gobo 3 shake and rotate

145 154 56.9 60.4

Snap

Gobo 4 shake and rotate

155 164 60.8 64.3

Snap

EXO Spot 30 User Manual Rev. D

35

www.glp.de

DMX control channel layout tables

Gobo 5 shake and rotate Gobo 6 shake and rotate Gobo wheel spin stop Gobo wheel spin clockwise fast > slow Gobo wheel spin stop Gobo wheel spin counterclockwise slow > fast

165 174 64.7 175 184 68.6 185 185 72.5
186 219 72.9 220 220 86.3
221 255 86.7

13

Gobo 2 Index/Rotate

14 Shutter
15 Dimmer 16 Dimmer fine

When Ch. 12 = “indexed” Gobo index 0-360° When Ch. 12= “rotate” Gobo rotation stop Gobo rotation clockwise fast > slow Gobo rotation stop Gobo rotation counterclockwise slow > fast Shutter closed Single flash when change on dimmer channel Sync ramp up slow­fast Sync ramp down slow­fast Sync ramp up-down slow­fast Sync double flash (slow­fast) Random strobe pixel (slow­fast) Random strobe all (slow­fast) Sync strobe (1 Hz­10 Hz) Shutter open
Intensity 0-100%

0

255

0

0

0

0

1

127 0.4

128 128 50.2

129 255 50.6

0

4

0

5

9

2.0

10

39

3.9

40

69 15.7

70

99 27.5

100 129 39.2

130 159 51.0

160 199 62.7

200 250 78.4

251 255 98.4

0 65535 0

17 Frost

Frost 0 ­ 100%

0

255

0

18 Prism

No prism Prism inserted

0

3

0

4

255 1.6

Variable position from 0-360°

0

191

0

Rotation stop

192 192 75.3

Rotation clockwise fast > slow 19 Prism rotation Rotation stop

193 223 75.6 224 224 87.8

Rotation counterclockwise slow > fast

225 255 88.2

20 Focus 21 Focus fine

Focus 0 > 100%

0 65535 0

22 Zoom

Zoom 0 > 100%

0

255

0

No function

0

9

0.0

Dimmer curve: Extra-soft (3s hold)

10

15

3.9

Dimmer curve: Linear (3s hold)

16

21

6.3

Display mode: Auto (3s hold)

22

27

8.6

Display mode: On (3s hold)

28

33 11.0

Display mode: Off (3s hold)

34

39 13.3

23

Control / Settings

Display orientation: Normal (3s hold) 40 Display orientation: Inverted (3s hold) 46

45 15.7 51 18.0

No DMX: Blackout (3s hold)

52

57 20.4

No DMX: Hold (3s hold)

58

63 22.7

No DMX: Stand-alone (3s hold)

64

69 25.1

Fan mode: Regulated (3s hold)

70

75 27.5

Fan mode: High (3s hold)

76

81 29.8

Fan mode: Medium (3s hold)

82

87 32.2

68.2

Snap

72.2

Snap

72.5

Snap

85.9

Fade

86.3

Snap

100

Fade

100

0 Fade

0

49.8 50.2

0 Fade

100

1.6

3.5

15.3

27.1

38.8 50.6

0

Snap

62.4

78.0

98.0

100

100

0 Fade

100

0 Fade

1.2

100

0 Snap

74.9

75.3

87.5 87.8

0 Fade

100

100 32767 Fade

100 128 Fade

3.5

5.9

8.2

10.6

12.9

15.3

17.6 20.0

0 Snap

22.4

24.7

27.1

29.4

31.8

34.1

36

EXO Spot 30 User Manual Rev. D

German Light Products® DMX control channel layout tables

Fan mode: Low (3s hold) Position feedback: Off (3s hold) Position feedback: On (3s hold) No function Tilt inversion: Off (3s hold) Tilt inversion: On (3s hold) Pan inversion: Off (3s hold) Pan inversion: On (3s hold) Zoom inversion: Off (3s hold) Zoom inversion: On (3s hold) Defog: Off Defog: On Defog: Quick Load Settings Preset1 Load Settings Preset2 Load Settings Preset3 PWM 600 Hz (5s hold) PWM: 2200 Hz (5s hold) PWM: 3000 Hz (5s hold) PWM: 4800 Hz (5s hold) PWM: 9600 Hz (5s hold) PWM: 25 kHz (5s hold) No function Return to default settings Reset Pan/Tilt (3s hold) Reset Head (3s hold) Reset All (3s hold)

88

93 34.5 36.5

94

99 36.9 38.8

100 105 39.2 41.2

106 117 41.6 45.9

118 123 46.3 48.2

124 129 48.6 50.6

130 135 51.0 52.9

136 141 53.3 55.3

142 147 55.7 57.6

148 153 58.0 60.0

154 159 60.4 62.4

160 165 62.7 64.7

166 171 65.1 67.1

172 177 67.5 69.4

178 183 69.8 71.8

184 189 72.2 74.1

190 195 74.5 76.5

196 201 76.9 78.8

202 207 79.2 81.2

208 213 81.6 83.5

214 219 83.9 85.9

220 225 86.3 88.2

226 231 88.6 90.6

232 237 91.0 92.9

238 243 93.3 95.3

244 249 95.7 97.6

250 255 98.0 100

Note 1: When CMY channels 8-10 are above zero, they take precedence over the static color wheel CMY controls on channels 5-7

To set fixed color on channel 5, ensure channel 8 is at zero. To set fixed color on channel 6, ensure channel 9 is at zero. To set fixed color on channel 7, ensure channel 10 is at zero.

EXO Spot 30 User Manual Rev. D

37

www.glp.de
13. Service

Service

Warning! There are no user-serviceable parts inside the fixture. Opening the fixture can compromise its IP65 rating and cause damage that is not covered by the product warranty. Any service operation that requires removal of a cover must be performed by a professional service technician with the tools, skills, and personal protective equipment to maintain high-powered lighting equipment safely and efficiently.
Cleaning
EXO Spot 30 fixtures require occasional cleaning to prevent the buildup of dust, dirt, and residue from atmospheric effects. Failure to keep the fixture clean will significantly reduce light output and may cause heat buildup and damage that is not covered by the product warranty. Regular cleaning will ensure maximum performance and reliable operation. The cleaning schedule depends on the operating environment. Check fixtures regularly for signs of dirt buildup. You can clean the fixture using a soft cloth slightly dampened with a household or automotive glass cleaning product. Do not apply pressure to the clear front or display on the back of the fixture, as you may scratch these surfaces. Use the tilt lock mechanism to hold the head in a vertical position for easier cleaning.
GLP Service and Support
Contact information for the nearest GLP Service and Support is available online at www.glp.de/en/service, by email at info@glp.de, or by telephone at the following numbers: GLP Germany: +49 (7248) 927 19-55 GLP N. America: +1 818 767-8899 GLP UK: +44 1392 690140 GLP Asia: +852 (3151) 7730 GLP Nordic: +46 737 57 11 40

38

EXO Spot 30 User Manual Rev. D

German Light Products®

Technical specifications

14. Technical specifications
Optics
Light source: Advanced 90W White LED Lifetime: 20 000 hrs. approx. to > 70% luminous output Luminous flux @ 7° zoom: 107100 lux @ 3 m, 38556 lux @ 5 m Beam angle (half peak): 7° – 30°
Control
Control systems: DMX, RDM, Manual setting DMX channel footprint: 24 Setting and addressing: Onboard control panel with LCD display, RDM DMX compliance: USITT DMX512 RDM compliance: ANSI/ESTA E1.20 Pan range: 540°, 16 bit resolution Tilt range: 258°, 16 bit resolution
Installation
Options: Stand on horizontal surface, suspended using truss mount brackets Operating position: Any Minimum distance to combustible materials: 0.5 m (20 in.) Minimum distance to illuminated surfaces: 0.5 m (20 in.) Installation environment: Temporary or permanent indoor installation, temporary outdoor installation Secondary attachment: Slot for safety cable attachment
Electrical
AC mains power: 100-240 V nominal, 50/60 Hz Power supply unit: Auto-ranging electronic switch mode Maximum power consumption, LED at 100% output: 295 W
Maximum permitted number of fixtures daisy-chained to power 6 x EXO Spot 30 total @ 100-120 V, 60 Hz 12 x EXO Spot 30 total @ 200-240 V, 50 Hz
Connections
AC mains power in and thru (out): Neutrik powerCON TRUE1 with sealing cap Control data in and thru (out): Neutrik 5-pin XLR with sealing cap
Construction
Ingress protection rating: IP65 Fixture housing: Aluminum, plastic Color: Black
Thermal
Cooling: Fan, Convection Minimum ambient temperature: -10° C (14° F) Maximum ambient temperature: 40° C (104° F)

EXO Spot 30 User Manual Rev. D

39

www.glp.de

Technical specifications

Included items
Power cable with Neutrik powerCON TRUE1 mains input plug
Dimensions and weight
Length: 368mm / 14.5 ins. Width: 380 mm / 15.0 ins. Height: 605 mm / 23.8 ins. Weight: 25.9 kg (57 lbs.)

40

EXO Spot 30 User Manual Rev. D

German Light Products®
15. Dimensions
All dimensions are in millimeters

Dimensions

EXO Spot 30 User Manual Rev. D

41

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals