LYNX GXR-215 Powered Multipurpose Cabinet User Manual

June 9, 2024
LYNX

GXR series
USER MANUAL
GXR-215LYNX GXR 215 Powered Multipurpose Cabinet Lynx Pro Audio S.L.

GXR-215 Powered Multipurpose Cabinet

LYNX GXR 215 Powered Multipurpose Cabinet - FIG

GXR-215

Manufacturer
LYNX Pro Audio S.L.
Calle 1 – Pol. Ind. Picassent
E-46220 Picassent (Valencia)

CE CERTIFICACTION, EUROPEAN PRODUCT
This user guide is property of Lynx Pro Audio S.L. Any reproduction of this manual, by any means is strictly prohibited.
Copyright 2020. All rights reserved.
INTRODUCTION
The GXR-215 enclosure has an excellent power-size ratio, does not need to carry out an external amplification rack and is the ideal solution as a compact portable PA system.  The enclosure has a 1400 W class D amplifier switching power supply, with DSP processor and linear phase FIR filters. This system can be controlled online in real  time.
At its base it has transport wheels that facilitate its movement. It has a nylon base to protect the box during transportation and storage. And for the reinforcement of the low  frequencies you can count on the support of the GXR- 18S subwoofer unit.
To facilitate, correct and reliable use of the powered cabinet GXR-215 we have designed this instruction manual.
Please read the manual carefully before proceeding to install the system.
Please observe the technical data carefully and do not ignore the instructions included within this manual.
Before starting to use this device, please read this instruction manual carefully.
Keep these instructions in the place where the equipment will be used and with easy access to them.

SAFETY PRECAUTIONS

  • Electrical appliance
    ** The exclamation mark within a triangle identifies the presence of electricity. Use the system carefully without wet hands or feet. Avoid installing the speaker in wet or  excesivelly humid places. Do not place material that contains liquid on or near the unit. Avoid dripping or splashing water or any liquid over the unit. Regularly check the  condition of the cables and make sure these are not being walked on or pinched. Connect the speaker to bipolar, earthed mains. The mains plug must be connected to  the appropriate protection (fuse or breaker). Connection to any other type of mains could result in an electrical shock and violate local electrical codes.
    CAUTION:** DO NOT CONNECT OR DISCONNECT THE AC POWER CONNECTORS UNDER LOAD.

  • Heavy equipment
     Apply back protection when using the system. Avoid loading and unloading at heights.

  • Electrical shock risk
    The diagonal mark within a triangle identifies the presence of dangerous voltage.
    Do not open or handle the interior of the box. These parts are not to be adjusted by the user. For maintenance and/ or repair please go to an authorized service  centre.In order to reduce the risk of electric shock, disconnect from AC before plug in or unplugging Audio signal cables. Reconnect to AC only if all signal connections  are made and secured. Never manipulate the ground type plug provided. The AC mains plugs should always remain accessible for operation. Unplug the loudspeaker during storms or when it’s being used for a long time.

  • Hearing damage risk
    These systems can reproduce large quantities of sound pressure which can damage hearing. Take precautions if you are going to be near them for extended amounts of time and do not get too close.

  • Hanging / Flying
    Do not hang the cabinets from the handles or from any other part other than the designated hanging point. When flying this system please observe the technical and “Rainbow” software data carefully. Never exceed the maximum safe working loads or ignore the instructions included within this manual. Use Only flying accessories provided by Lynx Pro Audio S.L. Rigging must be always carried out by professionals.

  • Delicate Material
    Please ensure no foreign object or water enters the speaker. Only clean the unit with dry cloths. Do not use solvents.

  • Overheating / Fire risk
    To reduce the risk of the speaker over heating, avoid direct contact with sunlight. Avoid placing the unit close to heat inducing objects such as radiators. Do not cover the equipment in use and do not block any ventilation openings. Do not put naked flame, such as lighted candles, close or on top of the unit.

  • Electromagnetic and interferente emissions
    Avoid placing objects which through electromagnetic waves can damage the unit, such as mobile phones, lap tops, magnetic strip cards etc.
    This system complies with normatives
    EN 55103-1 (1)
    EN 55103-2 (2)
    (1) This device may not cause harmful interferences.
    (2) This device may receive interference including interferences that may cause undesired working.

  • IMPORTANT NOTE
    This Equipment must be used in accordance with these instructions and by trained professional personnel only.
    This equipment should not be used in places with extreme tropical climates. Don’t expose this apparatus to extreme humidity and or temperature values.

SYSTEM OVERVIEW

  • GXR-215
    High Output, self powered (class D switch mode power supply with PFC), two-way cabinet.
    Consists of dual 15”(2.5”voice coil) transducer with a 1.4” compression driver mounted on a 60ºH x 50ºV constant directivity horn. DSP (FIR Filters) controlled with 1400W amplification, 131 dB SPL.

  • Technical Data:****
    Components:
    •LF
    •HF| 2 x 15”, 2.5” voice coil, Malt Cross Cooling System
    1.4” Exit compression Driver, 1.75” aluminium voice coil
    ---|---
    Frequency range:| 55 Hz – 20 KHz (-10dB)
    Frequency response:| 60 Hz – 18 KHz (± 3dB)
    Max SPL:| 131 dB
    Coverage angle:| 60º H x 50 º V constant directivity horn
    Power:| 1400W Class D with switching power supply & PFC
    LF amplifier:| 1 x 800 W
    HF amplifer:| 1 x 600 W
    Processing:| 96 KHz / 64 bit double-precision, DSP with FIR filter linear phase
    Control:| User control interface with 2.8” IPS screen
    Control connections:| Ethernet optional / USB (DSP programming)
    Input:| Analog / AES3 (optional)
    AC power:| 85 – 270V. 50/60 Hz with PFC
    AC connections:| 16A Neutrik powerCon TRUE1 TOP with looping output
    Finish:| Polyurea coating high grade resistant paint
    Material:| 15 mm Premium birch plywood
    Dimensions:| 1140 x 444 x 486 mm (H x W x D)
     Weight:| 45 kg (99 lbs)

  • GXR-215 measurementsLYNX GXR 215 Powered Multipurpose Cabinet - measurements

GXR-215 back panel

LYNX GXR 215 Powered Multipurpose Cabinet -
measurements1

CONNECTORS AND CONNECTIONS

LYNX GXR 215 Powered Multipurpose Cabinet -
measurements2LYNX GXR 215 Powered
Multipurpose Cabinet - measurements3

FIR FILTERS
Finite Impulse Response (FIR) filters are used in the signal processing of the cabinets. FIR is a type of digital filter with linear phase characteristics. This frees system designers from the constraints of phase anomalies associated withanalogue filters or their digital versions (IIR, Infinite Impulse Response). When properly used, FIR filtering can audibly improve a system’s impulse response and reduce crossover interference.
CONFIGURING THE CABINET DSP OPTIONS
On the back pannel of the cabinet you will find the digital control area. From the compact joystick located below the screen you are able to configure the Basic adjustment functions of the internal DSP. Just move the joystick to select the icons on the left of the screen. You can enter into the following functions:

LYNX GXR 215 Powered Multipurpose Cabinet - ICON5

Please note that you must apply the desired configuration in each one cabinet and requires electrical power to work.
If changes are not made the display will automatically dim to avoid unnecessary light in situations where light is not wanted. To re-activate the light simply press the joystick.

CONFIGURATION PANEL

| On the main screen you can see the cabinet’s input and output.
• Input:
You can see a vumeter with the input level and a clip signal.
• Output:
You have a vumeter with the output level (0 dBu is the amp’s maximum level) You can check the compressor and control the dynamic activity.
---|---
| On the second screen you can modify some parameters.
• Gain
• Mute
• Polarity
• Delay
• High Pass Filter: You can setup a High Pass filter selecting type, frequency and order.
| The folder screen shows you the name of the preset and its description.
Using the joystick you can change the preset.
| This screen is to configurate Ethernet. You can choose automatic or manual
You can also configure the screen saver.
And here you have the input selection. You can choose between analog or AES3 for channel 1 or channel 2.
| The last screen shows you some general information regarding the cabinet’s components.
Here you can see the cabinet model, its serial number, DSP firmware and hardware versions, amp module model with hardware version, as well as the accelerometer status.

ONLINE CONTROL SYSTEM

  • Who is it for?
    Users of Self powered DSP incorporated Lynx Pro Audio Cabinets where the user has requested the cabinets be supplied with the Ethernet Module kit.

  • What is it for?
    Obtain detailed information of cabinet behaviour and monitor the cabinet/s in real time. You can change the preset, gain, mute, polarity and phase. You can also activate the air absorption compensation and select the «SOLO» mode.

  • How does it work?
    Via Ethernet (cable or wireless). Once installed, the O.C.S. software automatically detects all the cabinets connected to the network and displays them in the O.C.S. window on the users PC.

  • What does it show?
    As well as displaying the cabinet model and IP address the O.C.S will be monitoring in real time and the user will be able to view RMS levels, Input clip, power module temperature, compression levels, air absorption compensation and cabinet angulation.

LYNX GXR 215 Powered Multipurpose Cabinet - FIG5

RAINBOW 3D Acoustic Prediction Software

Lynx Pro Audio’s R&D department is working on Rainbow 3D, a new acoustic simulation software with dynamic 3D features. With a sophisticated design, Rainbow 3D stands out for its speed, being able to provide a simulation in just a few seconds. It also provides algorithms for beam steering and optimizing the listening area.

  • Designed from scratch by professionals
    Rainbow 3D has been programmed from scratch by Lynx Pro Audio engineers, using new programming procedures that achieve an effective simulation with really low calculation time.

  • Multiple listening zones
    The program can simulate all Lynx Pro Audio’s acoustic enclosures located in a 3D space, including the classic side, top and front views. It can also define multiple listening zones and allows offset positioning and symmetry. Blueprint images, textures and PNG format pictures can be imported.

  • Unlimited sound sources
    Allows the acoustic simulation for an unlimited number of sound sources and audio systems. You can place as many systems (subwoofers, line arrays, columns and individual boxes) as you desire. Also, the line arrays can be placed in stack or flown configuration.

  • Beam steering
    Rainbow 3D has the ability to add DSP processing to the simulation and uses algorithms to control the directivity (beam steering) in columns, without the need to tilt them physically, being able to divide the column into several beams that point to different zones.

  • Accurate optimization thanks to FIR filters
    Optimized algorithms are used in the listening area to improve the sound coverage and the frequency response. This feature can be executed in a matter of seconds. Additionally, the export of FIR coefficients can be performed with the optimization for later loading in the DSP via Ethernet or a USB device. In the near future direct communication with Lynx Pro Audio and OCS will be available.

  • Multiple measures and tools
    Likewise, the R&D department is developing multiple measurement and analysis tools for the calculated data. For example, the sound pressure curves (SPL) in the listening areas and the capture of virtual measurements that show the frequency response in the points of location indicated and added. Among other tools you will find autosplay and a wizard to set up different subwoofer arragements.

LYNX GXR 215 Powered Multipurpose Cabinet - FIG6

HARDWARE AND ACCESSORIES

The GXR series include some accessories for installation and transport. The GXR-215 includes:

LYNX GXR 215 Powered Multipurpose Cabinet -
measurements4

DECLARATION OF CONFORMITY
Lynx Pro Audio S.L. declares that ionic series are in conformity with the following EC directives:

Low Voltage Directive 2006/95/EC
Electromagnetic Compatibility EMC 2004/108/EC
RoHS Directive 2002/95/EC

In accordance with Harmonized European Norms:

EN 60065:2002| Audio, video and similar electronic apparatus. Safety requirements
---|---
EN 55103-1:1996| Electromagnetic compatibility. Product family standard for audio, video, audiovisual and entertainment lighting control apparatus for professional use.
Part 1: Emission.
EN 55103-2:1996| Electromagnetic compatibility. Product family standard for audio, video, audiovisual and entertainment lighting control apparatus for professional use.
Part 2: Immunity.
GXR models:| GXR-LA10A / GXR-D15A / GXR-D18A / GXR-215 / GXR-15 / GXR-12 / GXR-18S

LYNX PRO AUDIO GUARANTEE
Lynx products are guaranteed against every kind of manufacturing fault 2 year after the date of sale. When products are under guarantee, the repairing and the free supplying of the device parts in order to correct any kind of defect are guaranteed by Lynx Pro Audio S.L. In the case that the product could not be returned to the factory for checking and repairing, Lynx Pro Audio S.L. would supply all the necessary parts.
Lynx Pro Audio S.L. is not responsible for any damage or defect caused during the transport or caused by an undue or improper handling y a non-authorized person during the life of this guarantee.
All our products undergo rigorous tests and quality controls. We guarantee the characteristics described here within and their quality against any fabrication defect.
The user loses all warranty rights if he incorporates or carries out any modification to the product, if he uses it outside of the stated safe working loads or does not secure the system properly using all the pins in their corresponding holes.
For any question regarding the product, the user must quote the model and serial number.
WEEE Declaration: Electrical and electronic equipment must be disposed of separately from normal waste at the end of its operational lifetime. Please dispose of this  roduct according to the respective national regulations or contractual agreements. If there are any further questions concerning the disposal of this product please contact Lynx Pro Audio S.L.

Lynx Pro Audio S.L.
Calle 1 – Pol. Ind. Picassent
46220 Picassent (Valencia)
SPAIN – EU
Tel.: (+34) 961 10 96 01
www.lynxproaudio.com

Documents / Resources

| LYNX GXR-215 Powered Multipurpose Cabinet [pdf] User Manual
GXR-215 Powered Multipurpose Cabinet, GXR-215, Powered Multipurpose Cabinet, Multipurpose Cabinet
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

LYNX User Manuals

Related Manuals