sauermann Si-RV3 Simplified Vacuum Probe User Manual
- June 9, 2024
- sauermann
Table of Contents
sauermann Si-RV3 Simplified Vacuum Probe User Manual
SAFETY INSTRUCTIONS
-
This device has been developed for the pressure and temperature measurements and settings on stationary or mobile refrigeration equipment. It must not be used in any other purpose.
-
This device has been developed, produced and sold exclusively to trained and qualified experts in the field of HVACR. Appropriate training is necessary in order to guarantee a riskless use of this instrument.
Sauermann is not responsible for any possible accident during its use. -
Please always use the device in accordance with its intended use and within parameters described in the technical features in order not to compromise the protection ensured by the devices.
-
Maximum operating pressure: 65 bar (942 psi)
-
The device must not be used with ammoniac refrigerant gas (NH3 / R717)
-
Do not use the device if it is damaged or if it operates abnormally. Inspect the device before every use.
-
Always wear protective glasses and gloves when using the Manifold in order to protect your eyes and skin when operating refrigerant gases. The vapors of refrigerant gases are extremely cold. Do not expose your skin to these vapors.
Please refer to the complete user manual of the Si-Manifold application to get more information about safety instructions.
DOWNLOAD THE APPLICATION
It is also possible to download the application by flashing the following
QR code:
Scan Me
Pair The Probes
| | | |
---|---|---|---|---
Press “Connect the probe” on the left-hand corner of the screen| Turn on the
low
pressure probe.| Press “Search for probes”.| Select the probe to pair and
press “Pair”.| After a few seconds, measured values are displayed.
CONNECT THE Si-RV3
For vacuum measurements:
- Press on the bottom of the screen to go to “Vacuum” mode..
- Connect the vacuum probe on the system to control.
LAUNCH A MEASUREMENT / DISPLAY DIFFERENT VIEWS / ACCESS TO PARAMETERS
Launch the measurement
- Power
Display different views of the measured values
- Press to display the values curves or press to display the values table.
Access to the application parameters
-
Press
-
Parameters list
Read the complete user manual of the SiManifold app to get information about
all the available functions.
Read User Manual Online (PDF format)