sauermann Si-RV3 Simplified Vacuum Probe User Manual

June 9, 2024
sauermann

sauermann Si-RV3 Simplified Vacuum Probe User Manual
sauermann Si-RV3 Simplified Vacuum Probe

SAFETY INSTRUCTIONS

  • This device has been developed for the pressure and temperature measurements and settings on stationary or mobile refrigeration equipment. It must not be used in any other purpose.

  • This device has been developed, produced and sold exclusively to trained and qualified experts in the field of HVACR. Appropriate training is necessary in order to guarantee a riskless use of this instrument.
    Sauermann is not responsible for any possible accident during its use.

  • Please always use the device in accordance with its intended use and within parameters described in the technical features in order not to compromise the protection ensured by the devices.

  • Maximum operating pressure: 65 bar (942 psi)

  • The device must not be used with ammoniac refrigerant gas (NH3 / R717)

  • Do not use the device if it is damaged or if it operates abnormally. Inspect the device before every use.

  • Always wear protective glasses and gloves when using the Manifold in order to protect your eyes and skin when operating refrigerant gases. The vapors of refrigerant gases are extremely cold. Do not expose your skin to these vapors.

Please refer to the complete user manual of the Si-Manifold application to get more information about safety instructions.

DOWNLOAD THE APPLICATION

  • Go to Google store or App store.
  • Search for “Si-Manifold” application.
  • Install the application.

It is also possible to download the application by flashing the following QR code:
Scan Me
QR. Code

Pair The Probes

Pair The Probes| Pair The
Probes| | |
---|---|---|---|---
Press “Connect the probe” on the left-hand corner of the screen| Turn on the low
pressure probe.| Press “Search for probes”.| Select the probe to pair and press “Pair”.| After a few seconds, measured values are displayed.

CONNECT THE Si-RV3

For vacuum measurements:

  • Press on the bottom of the screen to go to “Vacuum” mode..
  • Connect the vacuum probe on the system to control.
LAUNCH A MEASUREMENT / DISPLAY DIFFERENT VIEWS / ACCESS TO PARAMETERS

Launch the measurement

  • Power
    Using Instruction

Display different views of the measured values

  • Press to display the values curves or press to display the values table.
    Using Instruction

Access to the application parameters

  • Press

  • Parameters list

Read the complete user manual of the SiManifold app to get information about all the available functions.
Logo.png

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

sauermann User Manuals

Related Manuals