INSTALLATION INSTRUCTIONS NV5 & NV7 Series
WARNING
These products may represent a possible shock or fire hazard if improperly
installed or attached in any way. Products should be installed in accordance
with these instructions, current electrical codes, and/or the current National
Electric Code (NEC).
WARNING
The electrical rating of this product is 120V AC (NV5 & NV7) and 120-277V AC
(NV5-0/10V & NV7-0/10V), 60Hz. The installer must determine whether the power
supply is appropriate at the luminaire prior to installation. To avoid
possible electric shock, be sure that power source is turned off at fuse box
and/or circuit breaker prior to attempting installation or servicing of the
fixture.
WARNING
Use with a 4” octagonal or round junction box with a minimum depth of 1-1/4” .
Required distance between mounting holes: 3-1/2”.
Do not attempt to alter for other sizes or purposes.
SAFETY INFORMATION
-
Read all instructions before beginning; Save these instructions for future use.
-
To reduce the risk of fire, electric shock, or injury to persons, pay close attention to this manual and stay within its guidelines when using this product.
-
LED Disc light installation requires knowledge of recessed lighting luminaires and their electrical systems.
If not qualified or uncertain, do not attempt installation: contact a qualified electrician. -
Supply conductors (power wiring) connecting the fixture must be rated for a minimum of 90°C.
-
Do not make or alter any open holes in wiring enclosures, nor in any electrical components during kit installation.
-
Do not alter, relocate, or remove wiring, lamp holders, power supply, or any other electrical component.
-
This fixture is suitable for use in dry, damp, or wet locations.
-
Do not use these products in luminaires located where elevated ambient temperatures exist.
-
To avoid electrical shock, do not turn on fixture with missing or damaged lens.
-
There are no serviceable parts inside the fixture or LED module.
-
Use only a mild soap and water with soft cloth to clean the fixture. Harsh chemicals will damage the finish.
Do not wipe the fixture with a rough cloth that may scratch the finish or lens. -
This fixture is suitable for use in dimming circuits:
NV5-30-WH & NV7-30-WH: TRIAC/CL/ELV (FOR 120V ONLY) NV5-0/10V-30-WH & NV7-0/10V-30-WH: 0-10V
INSTALLATION
-
Ensure power is disconnected at the source and any wall switches are in the “off” position.
-
Affix the mounting plate directly to junction box using the mounting screws provided. See Figure 1.
-
Connect supply wires to fixture wires, ensuring to match polarity. For NV5-30-WH & NV7-30-WH (FOR 120V ONLY): Ground/Green to Ground, Common/White to White, Hot/Black to Black, and insulate connections with included wire nuts.
For NV5-0/10V-30-WH & NV7-0/10V-30-WH: Ground/Green to Ground, Common/White to White, Hot/Black to Black, then 0-10V wires Purple/+ to + and Grey/- to -, and insulate connections with included wire nuts. See Figure 2. -
Complete the installation by pushing the fixture into the mounting plate so the clips fully seat into the center of the plate.
See Figure 2. -
For wet location applications, seal the edge of the fixture where it meets the ceiling surface with waterproof silicone (Not provided).
-
For use with battery back-up (NV7-BB-WH sold separately),.
BATTERY BACK-UP INSTALLATION (Figures 3-5)
FIGURE 5
Emergency LED Indicator Colors/ Function
- Green: Emergency function working with battery
- Green Flashing: Lighting flashing, no power for the battery, recharging for the battery
- Off: Emergency function is off , the ceiling working with normal power supply
Emergency Battery Indicator Color and Functions
- Red: Battery is charging
- Green: Battery at full charge
- Red Flashing: Check system-possible battery replacement needed or system maintenance required
- Off: Indicates a power outage when the battery backup unit is in emergency mode the LED indicator will be Off
- Minimum Charge Time: 14hours
Test Button
- While main power is on: A quick press of the test button(<3 seconds), simulates the “main power outage” or emergency mode”. The light fixture will come in this case. It will be running on battery power.
- While in Emergency Status (mains power outage): Pressing test button for <6 seconds shuts off the unit; press again to turn it back on.
This battery back-up (NV7-BB-WH) is rated for an input voltage of 100-277V AC, 50-60Hz and produces an output power of up to 20W. It is intended for use with NV7-30-WH or NV7-0/10V-30-WH only.
PHOTOMETRIC DISTRIBUTION SHOWING INTENSITY (Candelas):
FCC Compliance Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
FCC WARNING
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment into an outlet different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
5-YEAR LIMITED PRODUCT WARRANTY
This product is warranted to be free from defects in material and workmanship for a period of five (5) years from the date of purchase. Products that prove to be defective during this period will be either repaired (i.e. replacement of defective electronics, defective parts of the fixture housing, lens, wiring, switching or lamp sockets; excluding the lamp) or replaced, at the discretion of American Lighting, Inc claims for defective products must be submitted to the retail location from which the product was purchased witching the warranty period. Upon submission of proper return claim documentation and product to American Lighting, Inc by the retailer, American Lighting, Inc reserves the right to inspect the product for misuse or abuse. Claims for indirect or consequential damages or for product that, in American Lighting, Inc’s opinion has bee misused, will be denied. This is a warranty of product reliability only and not a warranty of merchantability or fitness for a particular purpose. American Lighting, Inc shall have no liability whatsoever in any event for payment of incidental or consequential damages, including, without limitations, installation costs and damages for personal injury and property. These products may represent a possible shock or fire hazard if improperly installed or altered in any way. This warranty applied only to product that has been properly installed in accordance with instruction sheet and current local codes and/or the National Electrical Code. Warranty does not apply to any product that has been improperly installed or in situation where components have been altered in any way.
This warranty:
- excludes expendable parts including but not limited to light bulbs, batteries;
- carries a 2-year finish warranty protecting finish against tarnishing, flaking, and discolorations;
- shall be void if this lighting fixture is not installed in the U.S.A.; and
- does not cover any losses, labor, injuries to persons/property or costs.
This warranty does give you specific legal rights and you may have other
rights, which vary from state to state, Be careful, it is recommended that
installation be done by a qualified professional; the purchaser has sole
responsibility for proper installation in compliance with all state and local
code requirements. Seller’s employees are not qualified to advise you on the
use of this Merchandise. Any oral representation(s) made will not be binding
on seller or its employees. The rights under this limited warranty are to the
original purchaser of the Merchandise and may not be transferred to any
subsequent owner. This limited warranty is in lieu of all warranties,
expressed or implied including warranties or merchantability and fitness for a
particular purpose. Seller shall not be liable for any special, incidental, or
consequential damages. The sold exclusive remedy against the seller will be
for the replacement of any defects as provided herein, as long as the seller
is willing or able to replace this product or is willing to refund the
purchase price as provided above.
For questions/comments, technical assistance, or repair parts
- Please call toll free at 1-800-285-8051 (M-F 8am-5pm), CST)
©2021 American Lighting, Inc.
REV2136 www.AmericanLighting.com
11775 E. 45th Ave. Denver, CO 80239
Ph: 1-800-880-1180
Fax: 303-695-7633
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>