SHOWVEN SP0520 Sparkular Portable Battery User Manual
- June 13, 2024
- Showven
Table of Contents
SHOWVEN SP0520 Sparkular Portable Battery User Manual
Safety precautions
- Unauthorized repair are prohibited, it may cause serious incident.
- Keep SPARKULAR Portable Pack dry and do NOT use in rain or snow.
- If not used in 3 consecutive months, Please remember to recharge it.
- Frequent over discharge can cause the battery to fail. To prevent battery over discharge please maintain a certain amount of electricity and remember to charging it timely after use.
SPARKULAR Portable Pack SP0520/SP0521
| Support Model| SPARKULAR mini, SPARKULAR
Dimension| 266×235×130 mm
Weight| 7.5 kg
Input| 100-240VAC, 50/60Hz, 700W
Output| 220VAC (SP0520) 110VAC (SP0521) , 500W
Temp| -10℃~ 50 ℃
Casing Material| Iron
Battery Capacity| 24 V10 AH
Interface| Double AC power interfaces
Features :
- Easy operation.
- Charge/Discharge mode automatic switchover.
- Smart design, ensure SPARKULAR to get rid of dependence on power supply, achieve real wire less.
Interface:
- Two AC interface: compatible with stage effects plugs, It can also realize cascade charge and use with power link cables.
- One AC output for connection of SPARKULAR/SPARKULAR mini.
- One 5V DC output for wireless DMX.
- LCD screen shows the voltage of battery, which indicate the electricity quantity
Charging:
When connect with AC, SPARKULAR Portable Pack will automatically switch to
charging mode, it takes 4h to be fully charged, when voltage on LCD screen
reached 29.4V, means it is fully charged. When charging, Sparkular/Sparkular
mini can be used normally, it will not consume the power from battery.
UPS ON-OFF should on OFF status when charging
Usage:
When use SPARKULAR/SPARKULAR mini on it (not connect AC), please turn on UPS
ON-OFF switch. In low battery, device will alarm slightly, please recharge it.
Storage:
In storage, the SPARKULAR Portable Pack should keep some amount of power, and
turn off the UPS ON-OFF to avoid system drain battery power.
SPARKULAR mini can be used on the SPARKULAR Portable Pack directly. Due to the
power limitation, for SPARKULAR, please set at low power consumption mode,
otherwise will cause UPS halted. SPARKULAR set up as below: Press “ENTER” key
for 4s can enter Sparkular factory menu, press “MENU” to change interface and
find “Low Power Mode” interface as below, set it at “ON” status. If can’t find
“Low Power Mode” interface (available for software version V2.2 and above),
please contact SHOWVEN service team for software update.
https://www.facebook.com/Showven-228026294663699/?modal=admin_todo_tour
Showven Technologies Co., Ltd
Add: Building B1, Changsha E Center No.18, Xiangtai Road, Liuyang Economic
Development
Zone, Changsha City, 410300, Hunan Province, P.R.China.
Tel: +86-731-83833068
Web: www.showven.cn