RAB PARK34 Ceiling Mount Lighting Instructions

June 2, 2024
RAB

RAB PARK34 Ceiling Mount Lighting

RAB-PARK34-Ceiling-Mount-Lighting-product

IMPORTANT

READ CAREFULLY BEFORE INSTALLING THE FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
RAB fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.

WARNING: Make certain power is OFF before installing or maintaining fixture. No user-serviceable parts inside.

Mounting

CEILING MOUNT

The Fixture is suitable for outdoor applications in wet locations.

  1. Mount Ceiling Mounting Plate to junction box (not supplied), see Fig. 3 for Mounting Pattern. Use the appropriate mounting hardware for the mounting surface. May alternately be mounted to recessed junction boxes.

  2. Pull supply wires from junction box (not supplied). Use the appropriate wire connectors as required by code to make electrical splices to fi xture leads.

  3. Once connections are made push all wires back into
    junction box (not supplied). Be careful not to pinch wires. WARNING: To prevent wiring damage or abrasion, do not expose wiring to edges or sharp objects.

  4. Push Fixture into Ceiling Mounting Plate and rotate clockwise to lock in place, Fixture will snap into position. Once in position the Fixture should be tight and not easily rotated counter-clockwise.RAB-PARK34-Ceiling-Mount-Lighting-fig-1

PENDANT MOUNT

Fixture can be mounted to a 1/2” or 3/4” NPT Pendant. 3/4” to 1/2” NPT Adaptor is included.

  1. Feed supply wires through pendant (supplied by others). Wrap Tefl on® Tape or other thread sealer to the pendant threads to prevent moisture entry.
  2. Remove Ceiling Mounting Plate.
  3. Make wire connections using supplied wire nuts and feed into the fi xture.
  4. Thread the Housing onto Pendant. For 3/4” Pendant remove NPT Adaptor (Fig. 2).RAB-PARK34-Ceiling-Mount-Lighting-fig-2

MOUNTING PATTERN

PASSIVE INFRARED SENSOR / BI-LEVEL

For units ordered with /PIR/BL suffix the default settings are:

  1. When motion is detected the fixture will operate at 100%light output.
  2. If no motion is detected after 20 minutes the fixture will dim to 30% light output.
  3. These settings are not adjustable.

ON-OFF WIRING

PARK34/120 series operates at 120V, 50 or 60Hz only.
PARK34/277 series operates at 277V, 50 or 60Hz only. Follow the wiring directions as shown in Fig. 4.

  1. Connect the black fixture lead to the LINE supply lead.
  2. Connect the white fixture lead to the COMMON supply lead.
  3. Connect the GROUND wire from fixture to supply ground.

CLEANING & MAINTENANCE

CAUTION: Be sure fixture temperature is cool enough to touch. Do not clean or maintain while fixture is energized.

  1. Clean polycarbonate lens with non-abrasive cleaning solution.
  2. Do not open the fixture to clean the LEDs. Do not touch the LEDs.

TROUBLESHOOTING

  1. Check that the line voltage at the fixture is correct. Refer to wiring directions.
  2. Be sure the fixture is grounded properly.
  3. Is the photocell, if used, functioning properly?

Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance.

rablighting.com
Visit our website for product info

Tech Help Line
Call our experts: 888 722-1000

e-mail
Answered promptly – sales@rablighting.com

RAB WARRANTY: RAB’s warranty is subject to all terms and conditions found at rablighting.com/warranty
PATENT: Patent information can be found at rablighting.com/ip

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals