GE 93105002 Smart Switch, White Installation Guide
- June 3, 2024
- GE
Table of Contents
Smart Switch Installation Guide
On/Off Button Neutral Wire/4-Wire Switches
93105002 Smart Switch, White
WARNING: RISK OF ELECTRIC SHOCK
This product installation requires handling 120 volt wiring, Follow each
step carefully, If any concerns handling wiring, hire a qualified electrician.
Ensure all work meets applicable local and national codes.
Simple DIY Set Up
Compatibility Requirements
- Rating 120V AC 60Hz
- Neutral wire is required (Wire is usually white or grey)
- Ground wire is required (Wire is usually green, green with a yellow stripe, or copper) @
- Wi-Fi 802N b/g/n @ 2.4 GHZ is required
- Works with halogen, incandescent and LED bulbs, including Cync smart bulbs
- Mox LED rating 125 amps / SOW
- Max incandescent/halogen rating 5 amps / 450W
! IMPORTANT NOTE ON 3-WAY WIRING:
Some lights have one wall switch, while others ore controlled by two or more
wall switches (such as stair lights, which have Q switch of both the top and
bottom of the stairs). If your lights have more than one switch (called a
3-way), we’ve created instructions for how to install and enable the
capability. 3-way control requires 2 CYNC wired switches or 1 wired and wire-
free.
Visit cyncsupportgelighting.com for 3-way instaation instructions and how-
to videos.
Note: Complete set up in the CYNC App to enable 3-way/nwitti- way
functionality.
GE & 0 trademork of General Bectric Compony, Used under trademark license.
Amazon, Alexa, and oll related logos are trademarks of Amazonoom, Inc. of its
affictes.
Google ond other retoted marks and logos ore trademarks of Google LLC,
Let’s Do It
Included: You’ll
need:
Approximately 30 minutes of your day to install and set up the switch
You Got This!
For in-depth instructional videos and a quided tour through the installation,
go to: cyncsupport.gelighting.com or call
1-844-302-2943
Scan here for videos & guided installation steps.
BEFORE YOU DO ANYTHING: Step 1
Turn Off The Power!
- Turn off the power for the switch location at the circuit breaker box.
- Test existing switch by toggling switch on/off, ensuring lights do not turn on.
- Now, follow these setup steps for a single gang switch.
Step 2
Remove Your Old Switch
-
Remove the existing wall plate and switch from the wall.
-
Use voltage tester on the black wires to confirm power to the switch is off (recommended).
-
Before disconnecting the wires from the wall, label each with the provided wire labels.
A Neutral and ground wires are required. If you don’t have either wire, the Cync switch is not compatible. -
Disconnect wires and remove existing switch.
Step 3
Connect The Wires
-
Connect the neutral (white) wire on the switch to the neutral (white label) wire from the wall.
-
Connect one of the line/load (black) wires on the switch to the line/load (black label) wire from the wall.
-
Connect the remaining line/load (black) wire to the other line/load (black label) wire from the wall.
Li. Connect the ground (green) wire on the switch with the ground (green label) wire from the wall. -
Cap the 3-way/multi-way traveler wire (if applicable).
For 3-way switch setup, visit cyncsupport.gelighting.com
Attention: Incorrectly connecting the Neutral or Ground wire from the wall to the Line or Load wire on the switch will damage the product.
Step 4
Fit Wires Into Wall Box
Neatly push the wires back into the box, rotating the switch so it’s oriented
according to the image .
For set up help, visit cyncsupport.gelighting.com or call l-8Lili-302-29Li3.
Step 5
Secure The Switch
- Using a Phillips screwdriver and the screws provided, secure the switch to the wall until level and flush.
- Screw on the wall plate bracket, then snap the wall plate cover onto the bracket.
Step 6
Turn The Power Back On
After the switch is secured and wall plate mounted, turn the power back on at
the circuit breaker box. At the switch, the light ring will flash blue
indicating the device is wired correctly and the device is in setup mode.
Light ring will continuously flash blue until the switch is added to the Cync
App.
Light ring will not illuminate if wired incorrectly.
IF LIGHTS DON’T TURN ON:
- Check that power to the switch is on at the breaker.
- Turn power off at the breaker, return to the switch to confirm the wires are securely and properly wired according to the installation guide.
- Go to cyncsupport.gelighting.com for more troubleshooting.
Congratulations!
You’ve completed the Smart Switch installation.
Next … Enable
Your Voice Assistant
Connect to your Amazon Alexa or Hey Google voice assistants in the CYNC App.
Then try this …
Alexa, turn off the living room.
Alexa, turn on the bedroom.
Alexa, set kitchen to 50%
Hey Google, turn on the lights.
Hey Google, good morning.
Hey Google, I’m leaving.
Additional Information and Warnings
FCC Compliance Statement Compliance Notice: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which con be determined by turning the equipment off and on, the user is encouraged to try to correct the Interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This device complies with part 15 of FCC rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference.
- This device must accept any interference received, Including interference that may cause undesired operation. Changes or modifications that are not expressly approved by the manufacturer could void the user’s authority to operate the equipment.
RF Exposure Information: This equipment complies with FCC radiation
exposure limits set forth for an uncontrolled environment In order to ovoid
the possibility of exceeding the FCC radio frequency exposure limits, human
proximity to the antenna shall not be less than 8 Inches during normal
operation.
RF Exposure Statement: This equipment complies with IC RS5102 radiation
exposure limits set forth for on uncontrolled environment This transmitter
must be installed to provide a separation distance of at least 8 inches from
all persons and must not be collocated or operating in conjunction with any
other antenna or transmitter.
A Caution High Voltage
- Disconnect power supply before servicing
- Operation temperature: 0 to 40•C
- For Control of Electronic Ballast, CFLs, LED, and LED Lamps
- Type 1 Enclosure
- IP20
- Pollution Degree 2
- Impulse Volatge: 2500V
- Type 1.8 action
Indoor use only
Like your new Smart Switch?
Share your experience! Leave a review where you purchased the product. A 1 A
References
Read User Manual Online (PDF format)