POWERTECH MB3904 8 Step Intelligent Lead Acid and Lithium Battery Charger Instruction Manual
- June 3, 2024
- POWERTECH
Table of Contents
POWERTECH MB3904 8-Step Intelligent Lead Acid and Lithium Battery
Charger
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE
Charging Modes
The MB3904 has eight (8) modes. The Lithium and Recover charge modes require
the mode button to be pressed and held for three (3) seconds to enter the
enhanced mode. These “Enhanced” modes require your full attention before
selecting.
NEVER USE RECOVER MODE ON LITHIUM IRON PHOSPHATE BATTERIES.
Do not operate the charger until you confirm the appropriate charge mode for
your battery. Below is a brief description:
12V NORM
For charging 12-volt Flooded, Gel, Maintenance-Free batteries.
14.5V| 3.8A| 12-120Ah Batteries
12V NORM COLD/AGM
For charging 12-volt batteries in cold temperatures below 50°F (10°C) or AGM batteries. When selected, the LED will illuminate.
14.7V| 3.8A| 12-120Ah Batteries
12V SMALL
For charging 12-volt Flooded, Gel, Maintenance-Free batteries. When selected, the LED will illuminate.
14.5V| 900mA| 1.2-12Ah Batteries
6V NORM
For charging 6-volt Flooded, Gel, Maintenance-Free batteries. When selected, the LED will illuminate.
7.3V| 3.8A| 12-120Ah Batteries
6V COLD/AGM
For charging 6-volt batteries in cold temperatures below 50°F (10°C) or AGM batteries.
7.4V| 3.8A| 12-120Ah Batteries
12.8V LITHIUM (Press & Hold Mode) For charging 12.8-volt lithium iron
phosphate batteries. When selected, the LED will illuminate.
14.5V| 3A| 8-50Ah Batteries
12V RECOVER (Press & Hold Mode) For recovering and repairing and storing,
old, idle, damaged stratified or sulfated Flooded, Gel, Maintenance- Free Lead
Acid batteries. When selected, the LED will illuminate.
NEVER USE RECOVER MODE ON LITHIUM BATTERIES.
14.8V| 2A| 1.2-120Ah Batteries
PRODUCT SPECIFICATIONS
Input: | 220-240V AC 50 Hz 0.6A |
---|---|
Output: | 12V DC 3.8A / 0.9A |
6V DC 3.8A
12.8V DC 3.0A
Charges
Input: | 220-240V AC 50 Hz 0.6A |
---|---|
Output: | 12V DC 3.8A / 0.9A |
6V DC 3.8A
12.8V DC 3.0A
Charges
- 6/12V Lead Acid Flooded, Gel, Maintenance-Free, AGM Batteries
- 12V Small Mode: 1.2Ah-12Ah
- 6/12V Normal Mode: 12Ah-120Ah
- 12.8V Lithium Iron Phosphate (LiFePO4) 8Ah-50Ah
PREPARING TO CHARGE
- If necessary to remove the battery from the vehicle to charge, always remove the grounded terminal from the battery first. Make sure all accessories in the vehicle are off, so as not to cause an arc.
- Be sure area around the battery is well-ventilated while the battery is being charged.
- Clean battery terminals. Be careful to keep corrosion from coming in contact with the eyes.
- Study all battery manufacturer’s specific precautions while charging and recommended rates of charge.
- Determine the voltage of the battery by referring to car owner’s manual and make sure that the output voltage selector switch is set at the correct voltage. If the charger has an adjustable charge rate, charge the battery initially at the lowest rate.
CONNECTING TO BATTERY
-
Set any charger switches to the “off” position and remove ac cord from the electric outlet before connecting or disconnecting DC output clamps or eyelets. Never allow clamps or eyelets to touch each other.
-
Identify the correct polarity of the battery terminals. The positive battery terminal is typically marked with (POS, P, +). The negative terminal is typically marked with (NEG, N, -).
-
Position cords and cables to reduce the risk of damage by hood, door or moving parts (including fan blades, belts, and pulleys) or other parts that could cause injury to persons.
-
Do not connect to the carburetor, fuel lines, or sheet metal body parts.
-
Determine which post of the battery is grounded (connected) to the chassis. If the negative post is grounded to the chassis (as in most vehicles) see (f). If the positive post is grounded to the chassis, see (g).
-
For a Negative-grounded vehicle, connect the POSITIVE (RED) clamp from the battery charger to the POSITIVE (POS, P, +) post of the battery.
Connect the NEGATIVE (BLACK) clamp from the battery charger to the NEGATIVE (NEG, N, -) post of the battery. -
For a Positive grounded vehicle, connect the NEGATIVE (BLACK) clamp from the battery charger to the NEGATIVE (NEG, N, –) post of the battery. Connect the POSITIVE (RED) clamp from the battery charger to the POSITIVE (POS, P, +) post of the battery.
-
When disconnecting the charger, turn the switches to off, disconnect the AC cord, and remove connectors in reverse sequence from connecting procedure.
CHARGING
The battery charger must be connected to the battery according to the
instructions mentioned previously.
Starting the charging process:
- Once you have established that the battery clamps or eyelets have been correctly connected, you can start the charging process. To do so, insert the charger plug into the AC socket.
- The charger will start in Standby mode, indicated by the STAND BY LED.
- Press the mode button to select the appropriate charge mode (press and hold for three seconds to enter an enhanced charge mode) for the voltage and chemistry of your battery. The selected charge mode LED will illuminate.
LED DISPLAY
The state-of-charge (SOC) LED display has four (4) SOC indicators.
LED | Explanation |
---|
25% Red LED
| The LED will flash when the battery is less than 25% charged. When the battery is 25% charged, the LED will be solid.
50% Orange LED
| The LED will flash when the battery is less 50% charged. When the battery is 50% charged, the LED will be solid.
75% Yellow LED
| The LED will flash when the battery is less 75% charged. When the battery is 75% charged, the LED will be solid.
100% Green LED
| The LED will flash when the battery is less than 100% charged. When the battery is 100% charged, the LED will be solid.
ERROR DIAGNOSTICS
Error conditions are indicated in the LED display.
Error | Reason/Solution |
---|
Solid Red LED
| Standard Charging Mode| The battery is not accepting a charge. Change charge
mode to Recovery Mode.
Recovery Mode| The battery cannot be recovered.
Flashing Yellow LED| Battery capacity is too high for the selected mode.
Verify the battery capacity and charge mode.
Solid Yellow LED
| Battery voltage is too high or too low for the selected mode. Verify the
battery voltage and charge mode.
Flashing Red LED| Reverse polarity. Reverse the battery connections.
WARNINGS
-
For indoor use ONLY!
-
Do not charge non-rechargeable batteries.
-
Use this charger with a 6V or 12V Lead Acid battery only
-
During charging the battery must be placed in a well-ventilated area.
-
The battery is to be disposed of safely.
-
This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
-
Children should be supervised to ensure that they do not play with
the appliance. -
If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer or its services agent.
-
Disconnect the supply before making or breaking connections to the battery.
-
The battery terminal not connected to the chassis has to be connected first. The other connection is to be made to the chassis, remote from the battery and fuel line. The battery charger is then to be connected to the supply mains.
-
After charging, disconnect the battery charger from the supply mains. Then remove the chassis connection and then the battery connection.
-
The battery charger is not intended for use in electric vehicles.
Distributed by
Electus Distribution Pty. Ltd. 320 Victoria Rd, Rydalmere NSW 2116 Australia
www.electusdistribution.com.au Made
in China
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>