POWERTECH SB2560 12V 100Ah AGM Deep Cycle Battery Instruction Manual
- June 1, 2024
- POWERTECH
Table of Contents
- POWERTECH SB2560 12V 100Ah AGM Deep Cycle Battery
- Product Specifications
- Product Usage Instructions
- GENERAL FEATURES
- APPLICATIONS
- PRODUCT SPECIFICATIONS
- DIMENSIONS
- CONSTANT CURRENT DISCHARGE CHARACTERISTICS
- Curves of self-discharge
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
POWERTECH SB2560 12V 100Ah AGM Deep Cycle Battery
Product Specifications
- Nominal Voltage: 12V
- Nominal Capacity: 100Ah
- Design Life: 10 years
- Terminal: M8
- Approx. Weight: Approx 28.0kg (61.7lbs)
- Container Material: ABS
- Rated Capacity: 1
- Internal Resistance: 1
- Max Discharge Current: 591A (5min), 328A (2h)
- Operating Temperature: Please refer to the manufacturer’s recommendations
- Charge Method: Constant Current Discharge Characteristics
- Self Discharge: Please refer to the manufacturer’s recommendations
Product Usage Instructions
Charging the Battery:
- Ensure the battery is disconnected from any devices or systems.
- Use an appropriate charger that matches the battery specifications.
- Connect the charger to the battery following the correct polarity.
- Monitor the charging process and disconnect once fully charged.
Discharging the Battery:
- Connect the battery to the device or system you intend to power.
- Monitor the battery voltage to ensure it does not drop below the recommended levels.
- Disconnect the load if needed to prevent over-discharge.
Battery Maintenance:
- Keep the battery terminals clean and free from corrosion.
- Store the battery in a cool, dry place away from direct sunlight.
- Regularly check the battery’s voltage and charge status.
Frequently Asked Questions (FAQ):
-
Q: Can this battery be used in solar power systems?
A: Yes, this AGM deep cycle battery is suitable for use in solar power systems due to its design life and capacity. -
Q: What is the recommended charging current for this battery?
A: The recommended charging current may vary based on the charger used and the battery’s state. Refer to the manufacturer’s guidelines for specific recommendations. -
Q: How often should I check the electrolyte levels in this battery?
A: This AGM battery is maintenance-free and does not require checking or refilling of electrolyte levels.
GENERAL FEATURES
- High corrosion resistant performance: Pb-Ca multi-alloy grid
- High energy density and power density
- Optimized capability of instant high-current discharging
- Excellent charge acceptance ability
- Excellent deep cycle discharge capability
- Strong high and low temperature performance
- Precision sealing technology
- Long life
APPLICATIONS
- UPS/EPS
- Power systems
- Telecommunications system
- Emergency lighting, Auto control system
- Solar/wind generating storage cyclic
- Other general purpose
PRODUCT SPECIFICATIONS
Nominal Voltage: | 12V |
---|---|
Nominal Capacity: | 100Ah |
Design Life: | 10 years |
Terminal: | M8 |
Approx. Weight: | Approx 28.0kg (61.7lbs) |
Container Material: | ABS |
Rated Capacity: | 100Ah 20 Hour Rate (5.00A to 10.5V) 75.3Ah 3 Hour Rate (25.1A |
to 10.5V) 62.6Ah 1Hour Rate (62.6A to 9.60V)
Internal Resistance:| Full charged at 25°C: 5.0 mW
Max. Discharge Current:| 1200A(5S)
Operating Temperature:| Discharge: -20~50ºC Charge: -20~50ºC Storage: -20~50ºC
Charge Method:| Charge Current: Max. 25A; Recom. 10A
Float Charge: 13.5-13.8V, Recom. 13.5V (-18mV/ °C) Equalize Charge: 13.8-14.1V, Recom.14.1V (-24mV/ °C) Cycle Charge: 14.4-15.0V, Recom.14.4V (-30mV/ °C)
Self Discharge:| 3 % of capacity declined per month at 25°C
DIMENSIONS
Dimension: 330(L) × 171(W) × 216(H) × 219(TH) Unit: mm
CONSTANT CURRENT DISCHARGE CHARACTERISTICS
Unit: A (25ºC,77ºF)
FV/ Time | 5min | 15min | 30min | 1h | 2h | 3h | 5h | 8h | 10h | 20h |
---|---|---|---|---|---|---|---|---|---|---|
1.60V | 591 | 333 | 208 | 127 | 73 | 53.3 | 35.7 | 24 | 20 | 10.8 |
1.65V | 568 | 328 | 206 | 126 | 72.8 | 52.6 | 35.5 | 23.8 | 19.8 | 10.8 |
1.70V | 565 | 324 | 206 | 125 | 72.5 | 52.3 | 35.2 | 23.7 | 19.6 | 10.7 |
1.75V | 527 | 322 | 205 | 124 | 72.1 | 52 | 35 | 23.5 | 19.4 | 10.7 |
1.80V | 484 | 304 | 201 | 123 | 71.9 | 51.8 | 34.6 | 23.3 | 19.2 | 10.6 |
1.85V | 432 | 272 | 184 | 115 | 68.7 | 49.3 | 33 | 22.5 | 18.9 | 10.5 |
Unit: W/cell (25ºC,77ºF)
FV/ Time | 5min | 15min | 30min | 1h | 2h | 3h | 5h | 8h | 10h | 20h |
---|---|---|---|---|---|---|---|---|---|---|
1.60V | 328 | 176 | 107 | 62.6 | 35.9 | 26 | 17.5 | 11.5 | 9.67 | 5.07 |
1.65V | 317 | 171 | 105 | 62.2 | 35.7 | 25.8 | 17.3 | 11.4 | 9.57 | 5.05 |
1.70V | 305 | 167 | 103 | 61.8 | 35.4 | 25.4 | 17.1 | 11.3 | 9.48 | 5.02 |
1.75V | 280 | 161 | 102 | 60.8 | 34.9 | 25.1 | 16.9 | 11.2 | 9.39 | 5 |
1.80V | 251 | 151 | 98 | 59.3 | 34.2 | 25 | 16.5 | 11.1 | 9.29 | 4.97 |
1.85V | 224 | 134 | 89.4 | 54.9 | 32.5 | 23.5 | 15.7 | 10.7 | 9.01 | 4.89 |
Disclaimer:
Manufacturers have the right to self-modify the parameters of the product
updates, please keep in touch with manufacturers to obtain the latest
information.
Discharge characteristic
Charging characteristic
The effect of temperature on capacity
The effect of discharge depth on cycle life
Curves of self-discharge
The effect of temperature on float life
Distributed by:
Electus Distribution Pty Ltd 46 Eastern Creek Dr, Eastern Creek NSW 2766
Australia Ph 1300 738 555
Int’l + 61 2 8832 3200
Fax 1300 738 500
www.electusdistribution.com.au
References
Read User Manual Online (PDF format)