DMP XT Series Control Panel User Guide
- June 3, 2024
- DMP
Table of Contents
DMP XT Series Control Panel
IDENTIFY PANEL COMPONENTS
Identify the following panel components using your panel or the on-screen photo
- Reset header
- Programming header
- Outputs
- AC Power terminals
- Cellular pins
- 1100 Series antenna connection
- On-board zone terminals
- Network connection
- EXP header
POWER UP THE CONTROL PANEL
- Connect AC power to terminals 1 & 2
- Transformer type: 16.5VAC 40VA
- Connect battery backup to terminals 3 & 4
- Connect alarm bell to terminals 5 & 6
- Normal 12VDC is supplied to terminal 5, terminal 6 is ground reference
- 1/2 W 1K Ohm resistor should be added across the bell circuit for supervision
ENTER PANEL PROGRAMMER
- Reset the panel using the RESET JUMPER
- Enter 6653 (PROG) and press CMD
- Press CMD to navigate through the panel programmer menus
- Initialization
- Communication
- Network Options
- Device Setup
- Remote Options
- System Reports
- System Options
- Bell Options
- Output Options
- Output Setup
- Area Information
- Zone Information
- Stop
- Set Lockout Code
ADJUST COMMUNICATION TYPE
-
Navigate to to COMMUNICATION and press a toprow select area
-
Press a top-row select area to clear the default account number
-
Enter in a new account number
-
Press CMD to navigate to COMM TYPE
-
Press a top-row select area to display the communication types
-
Select NET
-
Press CMD to navigate to FIRST IP ADDRESS
-
Press a top-row select area and enter in the DMP
Tech Support receiver IP Address- 209.248.148.051 (Port 2001)
-
Press CMD to exit COMMUNICATION
ADD A KEYPAD
- Navigate to DEVICE SETUP and press a top-row select area
- Enter a device number and press CMD
- The valid range for an XT panel is 1-8
- Press a top-row select area and enter a device name
- Press CMD to exit DEVICE SETUP
ADJUST THE KEYPAD ADDRESS
GRAPHIC TOUCHSCREEN KEYPAD
- Select OPTIONS from the carousel
- Select the INSTALLER OPTIONS icon
- Enter 3577 (INST) and press CMD
- Select KPT OPT (KEYPAD OPTIONS)
- Press a top-row select area and enter a new keypad address
- Press CMD to exit KEYPAD OPTIONS
- Select STOP to save keypad programming
THINLINE KEYPAD
- Press and hold the BACK ARROW and CMD for 2 seconds
- Enter 3577 (INST) and CMD
- Select KPD OPT (KEYPAD OPTIONS)
- Press a top-row select key and enter a new keypad address
- Press CMD to exit KEYPAD OPTIONS
- Select STOP to save keypad programming
CONFIGURE SYSTEM OPTIONS
- Navigate to SYSTEM OPTIONS and press a top-row select area
- Press CMD to navigate to ENTRY DELAY 1
- Press a top-row select area and choose a time from 30 to 250 seconds
- Repeat this process for ENTRY DELAY 2
- Press CMD to navigate to EXIT DELAY
- Press a top-row select area and enter a time from 45 to 250 seconds
- Press CMD to navigate to HOURS FROM GMT
- Press a top-row select area and enter in the appropriate hours from GMT for your location and press CMD
- Press CMD to navigate to HOUSE CODE
- Press a top-row select area and enter a house code from 1-50 and press CMD
- Press CMD to navigate to ENTER WEATHER ZIP CODE
- Press a top-row select area and enter a local ZIP code to display weather alerts on the keypad
ADD A WIRELESS ZONE
- Navigate to ZONE INFORMATION and press a toprow select area
- Enter a ZONE NUMBER and press CMD
- Valid wireless zone numbers are 11-84
- Press a top-row select area and enter a ZONE NAME
- Press a top-row select area and select a ZONE TYPE
- Press a top-row select area to display the list of available areas and select the appropriate area for this zone
- At the NEXT ZONE? prompt, select NO to program a wireless zone
- At the WIRELESS? prompt, select YES and press CMD
- Enter a SERIAL NUMBER and press CMD to navigate to the NEXT ZONE? Prompt
ADD A WIRED ZONE
- Navigate to ZONE INFORMATION and press a toprow select area
- Enter a ZONE NUMBER and press CMD
- Press a top-row select area and enter a ZONE NAME
- Press a top-row select area and select a ZONE TYPE
- Press a top-row select area to display the list of available areas and select the appropriate area for this zone
- At the NEXT ZONE? prompt, select YES
- Navigate to STOP to save programming
STANDARD WALK TEST
- At the keypad, enter 8144 (WALK) to enter the WALK TEST menu
- Select STD to begin the standard walk test
- Walk around the installation site, tripping wired and wireless zones to complete the standard walk test
WIRELESS CHECK-IN TEST
- At the keypad, enter 8144 (WALK) to enter the WALK TEST menu
- Select WLS to begin the wireless check-in test without leaving the keypad
- The panel will send a message to each wireless device to ensure it is communicating properly
PIR WALK TEST
- At the keypad, enter 8144 (WALK) to enter the WALK TEST menu
- Select PIR to begin the PIR walk test
DIAGNOSTIC MENU
- At the keypad, enter 2313 (DIAG) to enter the DIAGNOSTIC MENU
- Navigate to CELL STATUS and press a top-row select area to begin the CELL STATUS test
- Press CMD to navigate to CELL SIGNAL and press a top-row select area to begin the CELL SIGNAL test
- Press CMD and select STOP to exit the DIAGNOSTIC MENU
ADD A USER CODE WITH PIN
- Enter the USER MENU and navigate to the USER CODES? prompt
- Press a top-row select area to add a USER CODE
- Select ADD
- Select the USER NUMBER and press CMD
- Enter in a 4-digit user code and press CMD
- Press a top-row select area to clear any text, add a USER NAME and press CMD
- Press a top-row select area to display the USER LEVEL
- Press CMD to save this user
ADD A USER CODE WITH CARD
- Enter the USER MENU and navigate to the USER CODES? prompt
- Press a top-row select area to add a USER CODE
- Select ADD
- Select the USER NUMBER and press CMD
- Scan the card by waving it over the blue status LED
- Press a top-row select area or key to clear any text, add a USER NAME and press CMD
- Press a top-row select area to display the user level
- Press CMD to save this user
ARM & DISARM
- Arm the system, trip an alarm and disarm
CHANGE THE SYSTEM TYPE TO H/S/A
- Enter the panel programmer by entering 6653 (PROG) at the keypad
- Navigate to SYSTEM OPTIONS and press a top-row select area
- Press a top-row select area to display the list of system types
- Select H/S/A as the system type
- Exit SYSTEM OPTIONS and navigate to STOP to
- Arm, disarm and trip an alarm in H/S/A system type
CHANGE THE SYSTEM TYPE TO AREA
- Enter the panel programmer by entering 6653 (PROG) at the keypad
- Navigate to SYSTEM OPTIONS and press a top-row select area
- Press a top-row select area to display the list of system types
- Select AREA as the system type
EDIT AREA NAMES
- Press CMD to navigate to AREA INFORMATION
- Press a top-row select area to enter AREA INFORMATION
- Enter an AREA NUMBER and press CMD
- Press a top-row select area to clear any text and enter in a new area name
- Exit AREA INFORMATION and navigate to STOP to save changes
- Arm, disarm and trip an alarm in Area system type
CONNECT THE 738Z PLUS
- Connect the 738ZPLUS by connecting the RED, YELLOW, GREEN AND BLACK wire terminals to the matching keypad bus terminals on the XT PCB
- The 738Zplus requires no additional programming before you can add a Z-Wave device
ADD A Z-WAVE LAMP MODULE
- At the keypad, press CMD until the USER MENU? prompt displays
- Select YES and enter a master level user code to enter the USER MENU
- Using CMD, navigate to Z-WAVE SETUP? and press a top-row select area
- Select ADD
- When the keypad displays ‘PRESS BUTTON ON Z-WAVE DEVICE’ press the button on the front of the lamp module
- When the panel recognizes the device, it will display ‘DEVICE FOUND’
- When the keypad displays ‘DEVICE ADDED’ press CMD
- Press a top-row select area to clear any text and name this Z-Wave device and press CMD
OPTIMIZE Z-WAVE
- At the Z-WAVE SETUP? menu, press CMD to advance the list and select OPT to optimize the Z-Wave signal After adding any Z-Wave device, it is recommended to optimize Z-Wave CREATE A FAVORITE
- At the Z-WAVE SETUP? menu, press CMD to advance the list and select FAV
- Enter a favorite number from 1-20 and press CMD
- Press a top-row select area to clear any text and name this favorite and press CMD
- Select ADD
- Press a top-row select area to add this device to the favorite
- Select SETTING and set the desired setting and press CMD to exit the FAVORITES menu
CREATE A FAVORITE SCHEDULE
- Enter the USER MENU and navigate to the SCHEDULES? prompt
- Press a top-row select area to enter the SCHEDULES? menu
- Select FAV to create a favorite schedule
- Enter a FAVORITE NUMBER and press CMD
- Select a day of the week and set the ACTIVATE TIME
- Continue this process for every day of the week
- Press the BACK ARROW to exit the USER MENU
BASIC ACCESS CONTROL
- Connect the 734 module to the KEYPAD BUS
- Use the dip switches on the 734 to address the module
- Reset the panel and enter 6653 (PROG) to enter the panel programmer
- Navigate to DEVICE SETUP, and program the 734 at the same address you set with the dip switches
- Connect the reader to TERMINALS 1–4 on the 734
- Connect the POSITIVE terminal on the external power supply to the C (common) terminal on the 734
- Connect the NEGATIVE terminal on the door strike to the NEGATIVE terminal on the external power supply
- Connect the POSITIVE terminal on the door strike to the NO (Normally Open) terminal on the 734
- Install the model 333 suppressor between the C and NO terminals on the 734
QUESTIONS
What else would you like to learn about the XT Series?
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>