DMP X1-3-ENC Single Door Access Controller User Guide

June 1, 2024
DMP

DMP X1-3-ENC Single Door Access Controller

DMP X1-3-ENC Single Door Access Controller

MOUNT THE MODULE

The metal enclosure for the XD Door Module needs to be mounted to a wall, backboard, or other flat surface. Compatible enclosures include Model X1-3-ENC and Model X1-OUT-EXP.
To install the XD Door Module, use screws to mount the PCB inside the metal enclosure following the 3 hole pattern.

ADDRESS THE MODULE

The XD Door Module has a 1 through 9 addressable rotary dial that is factory defaulted to 0. XD modules can only be addressed from 2-8. Additional modules need to be addressed in sequence.

CONNECT A CARD READER

The XD Door Module provides direct 12 VDC output to the reader on the RED terminal connection.

Terminal Name Wiegand Function OSDP Function
R1 & R2 12V+ DC +
W1 & W2 Data 1 B (485 +)
G1 & G2 Data 0 A (485 -)
B1 & B2 12V- (ground) DC –
LC LED Control N/A
BC Wiegand Buzzer Control N/A

WIRE THE INPUTS

Door Switch (DS) – Normally Closed
Connect a door contact or door position switch to indicate status of door, whether it is open or closed.

Request to Exit (RX) – Normally Open
Connect a motion sensing device or a mechanical switch to provide RX capability to the system.

Custom Input (CI) – Normally Open
This input triggers a custom action.

Ground (G)
This terminal is the ground for the inputs.
Wire The Inputs

WIRE THE ELECTRONIC LOCK

Form C Relay
The XD Door Module provides a Form C (SPDT) relay that is rated for 1 Amp.

Diode
Connect the included diode as close to the magnetic lock or door strike as possible to prevent inductive kickback. Observe polarity when connecting the diode.

WIRE THE MODULE TO CONTROLLER

Connect the XD Door Module to the X1 Door Controller with a 4-wire harness on the top header on the XD. Refer to the image below.

PROGRAM IN DEALER ADMIN™

Go to Dealer Admin to program the XD Door Module.
Program In Dealer Admin™

More Information

Follow the QR code to visit Dealer Admin.
QR Code

CUSTOMER SUPPORT

INTRUSION • FIRE • ACCESS • NETWORKS
Designed, engineered, and manufactured in Springfield, Missouri
2500 North Partnership Boulevard Springfield, Missouri 65803-8877 800.641.4282 | dmp.com