IDENTIFY PANEL COMPONENTS

Identify the following panel components using the panels in front of you, or the on-screen photo of the XR.

  1. AC Power terminals
  2. Cellular pins
  3. 100 Series antenna
  4. Reset header
  5. On-board zone
  6. Programming
  7. header
  8. terminals
  9. Network connection
  10. EXP header
  11. Outputs
  12. Connection

POWER UP THE CONTROL PANEL

  1. Connect AC power to terminals 1 & 2
  2. Transformer type: 16.5VAC 50VA
  3. Connect battery backup to terminals 3 & 4
  4. Connect alarm bell to terminals 5 & 6
  5. Normal 12VDC is supplied to terminal 5, terminal 6 is the ground reference
  6. 1/2 W 1K Ohm resistor should be added across the bell circuit for supervision

ENTER PANEL PROGRAMMER

  1. Reset the panel using the RESET JUMPER
  2. Enter 6653 (PROG) and press CMD
  3. Press CMD to navigate through the panel programmer menus:
    • Initialization
    • Communication
    • Network Options
    • Device Setup
    • Remote Options
    • System Reports
    • System Options
    • Bell Options
    • Output Options
    • Output Information
    • Output Groups
    • Status List
    • Menu Display
    • PC Log Reports
    • Area Information
    • Zone Information
    • Stop
    • Set Lockout Code
    • Feature Upgrade

ADJUST COMMUNICATION TYPE

  1. Navigate to COMMUNICATION and press a top-row select area
  2. Press a top-row select area to clear the default ACCOUNT NUMBER
  3. Enter in an ACCOUNT NUMBER
  4. Press CMD to navigate to PATH
  5. Press 1 to program PATH 1
  6. Press a top-row select area to display the COMMUNICATION types
  7. Select NET
  8. Press CMD to navigate to RECEIVER IP
  9. Press a top-row select area and enter in the DMP Tech Support receiver IP Address
  10. 209.248.148.051 (Port 2001)
  11. Press CMD to exit COMMUNICATION

ADD A KEYPAD

  1. Navigate to DEVICE SETUP and press a top-row select area
  2. Enter a DEVICE NUMBER and press CMD
  3. The valid range for an XR150 panel is 1-8, XR550 is 1-16
  4. Press a top-row select area and enter a DEVICE NAME
  5. Press CMD to confirm the DEVICE TYPE
  6. Press CMD to exit DEVICE SETUP

ADJUST THE KEYPAD ADDRESS

GRAPHIC TOUCHSCREEN KEYPAD

  1. Select OPTIONS from the carousel
  2. Select the INSTALLER OPTIONS icon
  3. Enter 3577 (INST) and press CMD
  4. Select KEYPAD OPTIONS (KPT OPT)
  5. Press a top-row select area and enter a new keypad address
  6. Press CMD to exit Keypad Options
  7. Select STOP to save keypad programming

THINLINE KEYPAD

  1. Press and hold the BACK ARROW and CMD for 2 seconds
  2. Enter 3577 (INST) and CMD
  3. Select KEYPAD OPTIONS (KPD OPT)
  4. Press a top-row select area or key to change the keypad address
  5. Press CMD to exit KEYPAD OPTIONS
  6. Select STOP to save keypad programming

CONFIGURE SYSTEM OPTIONS

  1. Navigate to SYSTEM OPTIONS and press a top-row select area
  2. Press CMD to navigate to ENTRY DELAY 1
  3. Press a top-row select area and choose a time from 30 to 250 seconds
  4. Repeat this process for ENTRY DELAY 2
  5. Press CMD to navigate to HOURS FROM GMT
  6. Press a top-row select area, enter in the hours from GMT for your location and press CMD
  7. Using CMD, navigate to HOUSE CODE
  8. Press a top-row select area and enter a house code from 1-50 and press CMD
  9. Using CMD, navigate to ENTER WEATHER ZIP CODE
  10. Press a top-row select area and enter a local ZIP code to display weather alerts on the keypad

ADD AN AREA

  1. Navigate to AREA INFORMATION and press a top-row select area
  2. Enter an AREA NUMBER and press CMD
  3. Press CMD until EXIT DELAY displays
  4. Press a top row select key or area and enter a time between 45 and 250 seconds
  5. Press a top-row select area to clear any text and enter in a new area name
  6. Exit AREA INFORMATION and navigate to STOP to save changes

ADD A WIRELESS ZONE

  1. Navigate to ZONE INFORMATION and press a top-row select area
  2. Enter a ZONE NUMBER and press CMD
  3. Press a top-row select area and enter a ZONE NAME
  4. Press a top-row select area and select a ZONE TYPE
  5. Press the top-row select area to display the list of available areas and select the appropriate area
  6. At the NEXT ZONE? prompt, select NO to program a wireless zone
  7. At the WIRELESS? prompt, select YES and press CMD
  8. Enter a SERIAL NUMBER and press CMD to navigate to the NEXT ZONE? Prompt

ADD A WIRED ZONE

  1. Add ZONE 1 as a hard-wired zone in the ZONE INFORMATION menu
    • EOL resistor value defaults to 1k, but you can change the value up to 2.2k for taking over an existing panel in System Options.

STANDARD WALK TEST

  1. At the keypad, enter 8144 (WALK) to enter the WALK TEST menu
  2. Select STD to begin the standard walk test
  3. Trip wired and wireless zones to complete the standard walk test

WIRELESS CHECK-IN TEST

  1. At the keypad, enter 8144 (WALK)
  2. Select WLS to begin the wireless check-in test

PIR WALK TEST

  1. At the keypad, enter 8144 (WALK)
  2. Select PIR to begin the PIR walk test

DIAGNOSTIC MENU

  1. At the keypad, enter 2313 (DIAG) to enter the DIAGNOSTIC MENU
  2. Press CMD until the keypad displays COMM STATUS and presses a top row select area
  3. Press 1 to test COMMUNICATION PATH 1
  4. When the signal strength is displayed, select YES to continue the test
  5. Cellular Communication Only
  6. Press CMD and select STOP to exit the DIAGNOSTIC MENU

EDIT AREA NAMES

  1. Press CMD to navigate to AREA INFORMATION
  2. Press a top-row select area to enter AREA INFORMATION
  3. Enter an AREA NUMBER and press CMD
  4. Press CMD until EXIT DELAY displays
  5. Press a top row select key or area and enter a time between 45 and 250 seconds
  6. Press a top-row select area to clear any text and enter in a new area name
  7. Exit AREA INFORMATION and navigate to STOP to save changes
  8. Arm, disarm, and trip an alarm in the Area system type

ARM & DISARM

Arm the system, trip an alarm and disarm

CHANGE THE SYSTEM TYPE TO A/P

  1. Enter the panel programmer by entering 6653 (PROG) at the keypad
  2. Navigate to SYSTEM OPTIONS and press a top-row select area
  3. Press a top-row select area to display the list of system types
  4. Select A/P as the system type
  5. Exit SYSTEM OPTIONS and navigate to STOP to save changes
  6. Arm, disarm and trip an alarm in A/P system type

CHANGE THE SYSTEM TYPE TO H/S/A

  1. Enter the panel programmer by entering 6653 (PROG) at the keypad
  2. Navigate to SYSTEM OPTIONS and press a top-row select area
  3. Press a top-row select area to display the list of system types
  4. Select H/S/A as the system type
  5. Exit SYSTEM OPTIONS and navigate to STOP to save changes
  6. Arm, disarm and trip an alarm in the H/S/A system type

CREATE A SCHEDULE

  1. At the keypad, press CMD until the USER MENU?prompt displays
  2. Select YES and enter 99+CMD to enter the USER MENU
  3. Using CMD, navigate to SCHEDULES? and press a top-row select area
  4. Select TIMES
  5. To create a time schedule, select ADD
  6. Press 1 to create Schedule 1
  7. Press a top row area to name the schedule ACCESS
  8. Press CMD and select a day of the week.
  9. Enter the BEGIN and END times for the chosen day
  10. Set times for each day of the week
  11. Create another schedule named LIGHTS

CREATE A PROFILE

  1. At the keypad, press CMD until the USER MENU?prompt displays

  2. Select YES and enter 99+CMD to enter the USER MENU

  3. Using CMD, navigate to PROFILES? and press a top-row select area

  4. Select ADD and enter 11 to create Profile 11

  5. Press a top row area to name the profile ACCESS

  6. Assign ARM/DISARM AREA 2 and press CMD

  7. Assign ACCESS AREA 2 and press CMD

  8. Press CMD until DISARM? displays and select YES

  9. Navigate to DOOR ACCESS and confirm it is set to YES

  10. Navigate to FIRST ACCESS SCHEDULE and press the third select area to enter the schedule number for the access schedule

  11. LIST will show the schedule names

  12. Press CMD until PROFILE 11 ADDED is displayed

  13. Create another profile named MANAGEMENT using Profile 12

  14. The instructor will provide settings for this profile
    ADD A USER CODE WITH A PIN

  15. Enter the USER MENU and navigate to the USER CODES? prompt

  16. Press a top-row select area to add a USER CODE

  17. Select ADD

  18. Select the USER NUMBER and press CMD

  19. The fourth top row select area will display the lowest available user number

  20. Enter in a 5-digit user code and press CMD

  21. Press a top-row select area to add a USER NAME and press CMD

  22. Press a top row select area and enter 12 to assign PROFILE 12 to this user

  23. LIST will display the profile names

  24. Press CMD until USER ADDED displays

ADD A USER CODE WITH A CARD

  1. Enter the USER MENU and go to USER CODES?
  2. Press a top-row select area to add a USER CODE
  3. Select ADD
  4. Select the USER NUMBER and press CMD
  5. Scan the card by waving it over the blue status LED
  6. Press a top-row select area and add a USER NAME and press CMD
  7. Press a top-row select area and enter 11 to assign PROFILE 11 to this user.
  8. Press CMD until USER ADDED displays

PROGRAM AN ANNUNCIATOR OUT-PUT

  1. Remove all power from the panel
  2. Connect a 4-wire harness to the OUTPUTS header on the panel
  3. Connect the POSITIVE leg of the LED to the RED terminal on the panel
  4. Connect the other leg of the LED to OUTPUT 3 on the panel
  5. Power the panel back up
  6. Enter the Programmer by entering 6653 (PROG) at the keypad
  7. Navigate to AREA INFORMATION and press a top-row select area
  8. Navigate to settings for AREA 1
  9. Navigate to ARMED OUTPUT and press a select area to clear the current setting
  10. Set the output to 3
  11. Navigate to STOP to save changes and exit the Programmer
  12. Arm AREA 1 to confirm the output is working

PROGRAM A RELAY

  1. Remove all power from the panel
  2. Plug a MODEL 305 relay into the socket for OUTPUT 1
  3. Make sure the relay is oriented correctly
  4. Connect the MODEL 431 harness to the header between the output sockets
  5. Connect the POSITIVE leg of the LED to the RED terminal on the panel
  6. Connect the other leg of the LED to the second ORANGE wire on the harness
  7. Connect the second GRAY wire to the BLACK terminal on the panel
  8. Power the panel back up
  9. Enter the Programmer by entering 6653 (PROG) at the keypad
  10. Navigate to ZONE INFORMATION and press a top-row select area
  11. Navigate to settings for ZONE 1
  12. Program ZONE 1 as a NIGHT type zone in AREA 1
  13. At the NEXT ZN? prompt, select NO
  14. Navigate to DISARMED SHORT and press CMD until OUTPUT NO is displayed
  15. Press a select area to set the output to 1.
  16. Set the output action to FOLLOW
  17. Navigate to STOP to save changes and exit the Programmer
  18. Press the button to trip ZONE 1.
  19. Notice the output state follows the zone state.

CREATE AN OUTPUT SCHEDULE

  1. Enter the user menu and press CMD until SCHEDULES? is displayed.
  2. Press a select area, then select TIMES, then ADD.
  3. Enter 1 for the schedule number, then name the schedule LED.
  4. Set begin and end times for each day of the week.
  5. When all times are set, press the BACK ARROW until SAVING SCHEDULES is displayed on the keypad.
  6. Re-enter the schedule programming section. Press CMD and select OUTPUT.
  7. Enter output 1, then schedule 1.
  8. Press the BACK ARROW to exit scheduled programming.
  9. Advance panel time to test the beginning and end times for the schedule.