tienda MERY IK10 Metal Wiegand Reader User Manual
- June 3, 2024
- tienda MERY
Table of Contents
Metal Wiegand Reader (IK10)
User Manual
Introduction
The devices are advanced access control readers with 125KHz &13.56MHz RFID
technology. It’s an ideal choice for high-security applications. They are
attractively designed with IK10 certification which brings better protection.
The readers are very powerful, can read many types of cards as below:
Frequency | Card Type |
---|---|
125KHz | HID & EM cards |
13.56MHz | NXP Mifare, Mifare Plus, DesFire, Mifare Pro, Mifare UltraLight, |
Mifare Class 4K and NFC cards
Specifications
Operation Voltage | 9-24V DC |
---|---|
Standby Current | 550mA |
Frequency | 125KHz & 13.56MHz |
Card Type | EM & HID & MIFARE |
Read Range | 2-6 cm |
Output Format | Wiegand 26-58 Bits |
Operating Temperature | -40°C – +60°C (-40°F – 140°F) |
Operating Humidity | 0% – 98% RH |
Color | Silver |
Index of Protection | IK10 and IP66 |
Dimension | L105 x W49 x H21 (mm) |
Net Weight | 240g |
Shipping Weight | 270g |
Installation
- Drill 2 holes (A,C) on the wall for the screws and one hole for the cable
- Knock the rubber bungs to the holes (A,C)
- Fix the back cover on the wall with 2 screws
- Thread the cable though the cable hole (B)
- Attach the unit to the back cover
Wiring
Color | Function | Notes |
---|---|---|
Red | Power | 9-24V DC |
Black | GND | Ground |
Green | DO | Data 0 |
White | D1 | Data 1 |
Brown | LED | Green LED Light Control |
Yellow | Buzzer | Buzzer Control |
Connection
Programming
The readers are equipped with an IR remote control, users can use it to
program the Wiegand output format if needed.
6.1 Enter and Exit Program Mode
Programming Step | Keystroke Combination |
---|---|
1.Enter Program Mode | *(Master Code)# |
(Factory default is 123456)
2.Exit Program Mode| *
Note: Master Code can not be changed
6.2 Set Wiegand Format for EM Cards
Programming Step | Keystroke Combination |
---|---|
1. Enter Program Mode | *(Master Code)# |
2. Set Wiegand Format | 1 (26-44) # (Factory default is 26bits) |
3. Exit Program Mode | * |
6.3 Set Wiegand Format for HID Cards
Programming Step | Keystroke Combination |
---|---|
1. Enter Program Mode | *(Master Code)# |
2. Set Wiegand Format
OR
2. Recognize Card ForrnatAutomatically| 2 (26-37) #
2 0 # (Factory default)
3. Exit Program Mode
*|
6.4 Set Wiegand Format for MIFARE Cards
Programming Step | Keystroke Combination |
---|---|
1. Enter Program Mode | *(Master Code)# |
2. Set Wiegand Format
OR
2. Recognize Card Format Automatically (4byte card output WG34, 7 byte card
output WG58)| 3 (26-44, 56, 58) #
(Factory default is Wiegand 34 bits)
3 0 # (Apply for WG34 and WG58 only)
3. Exit Program Mode| *
Note: WG56 is without parity bits, WG58 is with parity bits.
6.5 Reset to Factory Default
Programming Step | Keystroke Combination |
---|---|
1.Enter Program Mode | *(Master Code)# |
2.Reset to Factory Default | 50 # |
3.Exit Program Mode | * |
Function Table Sheet
Read Card| The LED light will turn into Green, and the buzzer sounds a beep,
at the meantime, the reader outputs the Wiegand signal
---|---
External LED Control| When the input voltage for LED is low, the LED will turn
into Green
External Buzzer Control| When the input voltage for Buzzer is low, the buzzer
will sound
Wiegand Data Output| The Wiegand output is 26-58 bits
Packing List
Name | Quantity |
---|---|
Reader | 1 |
Manual | 1 |
IR Remote Control | 1 |
Screw Driver | 1 |
Wall Fixing Plugs | 2 |
Self Tapping Screws | 2 |
Read User Manual Online (PDF format)