tienda MERY HF1 Outdoor FingerKey and Reader User Manual

June 3, 2024
tienda MERY

Out door FingetKey &Reader

User Manual

INTRODUCTION

The device is a single door multifunction standalone access controller or a Wiegand output reader. It uses Atmel MCU assuring stable performance. The operation is very user-friendly, and low-power circuit makes it long service life.
The device supports 1,000 users (988 common users + 2 panic users + 10 visitor users), all user data can be transferred from one to another (except fingerprint users). It supports multi access modes in card access, PIN access, fingerprint access, card + PIN access, or multi cards /PINs/ fingerprints access. It has extra features including block enrollment, interlock, Wiegand input & output interface…etc.
Two Versions Optional: T
he device with Bluetooth function is optional
The device with big user capacity is optional
Features
> Capacitive fingerprint sensor, Touch key

Metal case, anti-vandal
Waterproof, conforms to IP66
One relay, 1,000 users (988 common + 2 panic + 10 visitor)
PIN length: 4-6 digits > EM card, Mifare Card optional
EM card version: Wiegand 26-44 bits input & output Mifare card version: Wiegand 26-44bits, 56bits, 58bits input & output
Can be used as Wiegand reader with LED & buzzer output
Card block enrollment
Tricolor LED status display
Integrated alarm & buzzer output
Pulse mode, Toggle mode
User data can be transferred (except fingerprint users)
2 devices can be interlocked for 2 doors
Built-in light dependent resistor (LDR) for anti tamper
Backlit keypad, can set automatic OFF after 20 seconds

Specifications

User Capacity
Common User
Panic User
Visitor User| 1000
988 (100 Fingerprint + 888 Card/PIN Users)
2
10
---|---
Operating Voltage
Working Current
Idle Current| 12∼28V AC/DC
<150mA
<60mA
Proximity Card Reader
Radio Technology
Read Range| EM orMifare
125KHz/ 13 56MHz
2-6cm
PIN Length| 4-6 digits
Wiring Connections| Relay Output, Exit Button, Alarm, Door Contact, Wiegand Input, Wiegand Output
Relay
Adjustable Relay Output Time
Lock Output Load| One (NO, NC, Common)
0-99 Seconds (5 seconds default)
2 Amp Maximum
Wiegand Interface
PIN Output| EM card version: Wiegand 26-44 bits nput & output (Factory Default: Wiegand 26bits) Mifare card version: Wiegand 26-44bits,  56bits, 58bits input & output Factory Default: Wiegand 34bits)
4 bits, 8 bits(ASCII), 10 digits Virtual Number
Factory Default: 4 bits)
Enviro n ment
Operating Temperature
Operating Humidity| Meets IP66
-30C-60C (-22F 140E)
0%RH-98%RH
Physical
Colour
Dimensions
Unit Weight
Shipping Weight| Zinc-Alloy
Silver & Black
L145 xW68 x D25 (mm) Wide
L149W70 D25 (mm) Ellipse
500g (Wide) 455g(Ellipse)
615g(Wide) 565g(Ellipse)

Carton Inventory

tienda MERY HF1 Outdoor FingerKey and Reader - fig

INSTALLATION

  • Remove the back cover from the unit
  •  Drill 2 holes(A,C) on the wall for the screws and one hole for the cable
  •  Knock the supplied rubber bungs to the screw holes(A,C)
  • Fi the back cover firmly on the wall with 4 flat head screws
  • Thread the cable through the cable hole(B)
  • Attach the unit to the back cover

tienda MERY HF1 Outdoor FingerKey and Reader - fig1

Wiring

Wire Color Function Notes

Basic Standalone Wiring
Red| AC&DC| 12-28V AC/DC Regulated Power Input
Black| AC&DC| 12-28V AC/DC Regulated Power Input
Pink| GND| Negative Pole
Blue| Relay NO| Normally Open Relay Output (install diode provided)
Purple| Relay Common| Common Connection for Relay Output
Orange| Relay NC| Normally Closed Relay Output (Install diode provided)
Yellow| OPEN| Request to Exit(REX) Input
Pass-Through Wiring (Wiegand Reader or Controller)
Green| Data 0| Wiegand Output (Pass-through) Data 0
White| Data 1| Wiegand Output (Pass-through) Data 1
Advanced Input and Output Features
Grey| Alarm Output| Negative contact for Alarm
Brown| Contact Input| Door/Gate Contact Input (Normally Closed)

Sound and Light Indication

Operation Status LED Buzzer
Stand by Red light bright
Enter into programming mode Red light shines One beep
In the programming mode Orange light bright One beep
Operation error Three beeps
Exit from the Programming mode Red light bright One beep
Open lock Green light bright One beep
Alarm Red light Shines quickly Beeps

Basic Configure – – – ————
Enter and Exit Program Mode

Programming Step Keystroke Combination
Enter Program Mode * (Master Code) #

(Factory default is 123456)
Exit Program Mode| *

Set Master Code

Programming Step Keystroke Combination
1.Enter Program Mode * (Master Code) #
2.Update Master Code 0 (New Master Code) # (Repeat New Master Code) # (Master

code is any 6 digits)
3.Exit Program Mode| *

Set the Working Mode
Notes: The device has 3 working modes: Standalone Mode, Controller Mode, Wiegand Reader Mode, choose the mode you use. (Factory default is Standalone Mode / Controller Mode)

Programming Step Keystroke Combination
1.Enter Program Mode * (Master Code) #

2.Standalone/Controller Mode OR
2. Wiegand Reader Mode| 7 7 # (Factory default) 7 8 #
3.Exit| *

STANDALONE MODE

The device can work as Standalone Access Control for single door.
(Factory default mode)– 7 7#
Connection Diagram
Common Power Supply

tienda MERY HF1 Outdoor FingerKey and Reader - paower
saply

Attention:
Install a 1N4004 or equivalent diode is needed when use a common power supply, or the keypad might be damaged. (1 N4004 is included in the packing)
Access Control Power Supply

tienda MERY HF1 Outdoor FingerKey and Reader - paower
saply1

Programming
Programming will be vary depending on access configuration. Follow the instructions according to your access configuration.
Notes:

User ID number: Assign a user ID to the access fingerprint/ card/ PIN in order to track it
The Common User ID:
– Fingerprint user ID 0 – 98
– PIN/ Card user ID. 100 – 987
Master Fingerprint User ID: 99
Panic User ID·988-989
Visitor User ID 990-999
IMPORTANT: User IDs do not have to be proceeded with any leading zeros.
Recording of User ID is cntical. Mochfications to the user require the User ID be available.

> Proximity Card:
Proximity Card. 125KHz EM card or 13.56MHz Mifare card

PIN: Can be any 4-6 digits except 8888 which is reserved.
Add Common Users
(Fingerprint user ID: 0 – 98, PIN/ Card user ID: 100 – 987; PIN length: 4-6digits except 8888)

Programming Step Keystroke Combination
1.Enter Program Mode * (Master Code) #

Add Fingerprint User
2.Using Auto ID
(Allows the device to assign
Fingerprint to next available User
ID number)
OR
2. Select Specified ID
(Allows Master to define a specific User ID to associate the fingerprint to)| 1 (Fingerprint) (Repeat
Fingerprint) (Repeat Fingerprint again)
Fingerprints can be added continuously.
1 (User ID) # (Fingerprint)
(Repeat Fingerprint) (Repeat Fingerprint again)
Fingerprints can be added continuously.
Add Card User

2. Using Auto ID
(Allows the device to assign Card to next available User ID number)
OR
2. Select Specific ID
(Allows Master to define a specific User ID to associate the card to) OR
2. Add Card: Block Enrollment (Allows Masterto add up to 888 cards to the Reader in a single step) Takes 2 minutes to program.| 1 (Read Card)! (Input 8/10/17 Digits Card Number) #
The cards can be added continuously.
1 (User ID) # (Read Card)!
(Input 8/10/17Digits Card Number)#
1 ( User ID) # (Card Quantity) # (The First Card 8/10/17Digits Number)# Cards’ number must be consecutive; Card quantity = number of cards to be enrolled
Add PIN User
2. Using Auto ID
(Allows the device to assign PIN to next available User ID number)
OR
2.Select Specific ID
(Allows manager to define a specific User ID to associate the PIN to)| 1 (PIN) )#
The PINs can be added continuously
1 (User ID) # (PIN ) #
3.Exit| *

Tips for PIN Security (Only valid for 6 digits PIN):
For higher security we allow you to hide your correct PIN with other numbers up to a max of 10 digits
Example PIN. 123434
You could use (123434) 0r(123434)
( can be any numbers from 0-9)
Add Master Fingerprint (By Specified ID: 99)

Programming Step Keystroke Combination
1. Enter Program Mode * (Master Code) #
1. Add Master Fingerprint 1 (99) # (Fingerprint) (Repeat Fingerprint)

(Repeat Fingerprint again)
3. Exit| *

Add Panic Users (Valid for Card/ PIN Users)
(User ID number is 988, 989; PIN length: 4-6 digits except 8888)

Programming Step Keystroke Combination
1.Enter Program Mode * (Master Code) #

2.Add Card
OR
2. Add PIN| 1 (User ID) # (Read Card I Input 8/10 /17 Digits Card number)#
1 (User ID) # (PIN) )#
3.Exit| *

Add Visitor Users (Valid for Card/ PIN Users)
(User ID number is 990-999; PIN length: 4-6 digits except 8888)
There are 10 groups Visitor PIN/card available, the users can be specified up to 10 times of usage, after a certain number of times, i.e. 5times, the PIN/card become invalid  automatically.

Programming Step Keystroke Combination
1.Enter Program Mode *(Master Code) #

2.Add Card OR
2. Add PIN| 1 (User ID) # (0-9) # (Read Card)! (Input 8/10/17 Digits Card Number) #
1 (User ID) # (0-9) # (PIN) #
(0-9 means times of usage, 0=10 times)
3.Exit| *

Change PIN Users (PIN length: 4-6 digits except 8888)

Programming Step Keystroke Combination

Note: Below Is done outside programming mode, users can undertake this themselves
Change PIN| (User ID) # (Old PIN) # (New PIN) # (Repeat New PIN) #
Change PIN of Card + PIN access mode (There will auto allocate PIN (8888) to cards when adding)|
(Read Card) (Old PIN) # (New PIN) # (Repeat New PIN) #
Programming Step| Keystroke Combination
---|---
1. Enter Program Mode| (Master Code) #
2. Delete User- By Fingerprint/ Card/ PIN
OR
2. Delete User – By ID number OR
2. Delete User – By Card number OR
2. Delete ALL Users| 2 (Input Fingerprint)/ (Read Card)/ (Input PIN) #
The users can be deleted continuously.
2 (User ID )#
2 (input 8/10/17 Digits Card Number) #
2 (Master Code)#
3. Exit|

Set Relay Configuration
The relay configuration sets the behaviour of the output relay on activation.

Programming Step Keystroke Combination
1. Enter Program Mode *(Master Code) #

2. Pulse Mode OR
2. Toggle Mode| 3 (1–99)# (factory default)
The relay time is 1-99 seconds.
(Default is 5 seconds)
3 0 #
Sets the relay to ON/OFF Toggle mode
3. Exit| *

Set Access Mode
For Multi user access mode, the interval time of reading can not exceed 5 seconds, or else, the device will exit to standby automatically.

Programming Step Keystroke Combination
1. Enter Program Mode *(Master Code) #

2 Fingerprint Access
OR
2 Card Access
OR
2 PIN Access
OR
2 Card+ PIN Access| 4 0#
4 1 #
4 2#
4 3#
Simplified Instruction

Function Description| Operation
Enter the Programming Mode| – Master Code – #
then you can do the programming (123456 is the factory default master code)
Change the Master Code| 0 – New Code – # – Repeat the New Code – #
(code: 6 digits)
Add Card User| 1 – Read Card – #
(can add cards continuously)
Add Fingerprint User| 1-Fingerprint- Repeat Fingerprint-Repeat Fingerprint Again- #
Add PIN User| 1 -PIN -#
(The PIN is any 4-6 digits except 8888 which is reserved )
Delete User| 2- Fingerprint- # 2-Read Card- # 2-PIN-#
Exit from the Programming Mode|

How to release the door
Fingerprint User| Input Fingerprint
Card User| Read Card
PIN User| Input PIN #
2 Multi User Access
OR
2 Fingerprint or Card or PIN Access| 4 3 (2-9) #
(Only after 2-9 valid users, the door be opened)
4 4 # (factory default)
---|---
3. Exit| *

Set Strike-out Alarm
The strike-out alarm will engage after 10 failed entry attempts (Factory is OFF).
It can be set to deny access for 10 minutes after engaging or disengage only after entering a valid Finerprint/ card/ PIN or Master code/ fingerprint/ card.

Programming Step Keystroke Combination
1.Enter Program Mode * (Master Code) #

2.Strike-Out OFF OR
2. Strike-Out ON
OR
2. Strike-Out ON (Alarm)
Set Alarm Time| 6 0 # (factory default)
61 # Access will be denied for 10minutes (Exit button is still workable)
6 2#
5 (0 – 3) # (factory default Is 1 minute) Enter Master Code # or Master Fingerprint / Card or valid user fingerprint / card / PIN to silence
3. Exit| *

Set Door Open Detection
Door Open Too Long (DOTL) Detection
When use with an optional magnetic contact or built-in magnetic contact of the lock, if the door is opened normally, but not dosed after 1 minute, the inside buzzer will beep  automatically to remind people to dose the door. The beep can be stopped by closing the door, master users or valid users, or else, it will continue to beep the same time with  the alarm time set.
Door Forced Open Detection
When use with an optional magnetic contact or built-in magnetic contact of the lock, if the door is opened by force, the inside buzzer and external alarm (if there is) will both  operate, they can be stopped by master users or valid users, or else, it will continue to sound the same time with the alarm time set.

Programming Step Keystroke Combination
1. Enter Program Mode * (Master Code)#

2. Disable Door Open Detection OR
2. Enable Door Open Detection Set Alarm Time| 6 3# (factory default)
6 4#
5 (0 — 3) # (factory default is 1 minute)
3. Exit| *

The function of Set Alarm Time also apply for anti-tamper alarm
Set Audible and Visual Response

Programming Step Keystroke Combination
1. Enter Program Mode * (Master Code)#

2 Disable Sound
Enable Sound
OR
2. LED Always OFF
LED Always ON
OR
2. Keypad Backlit Always OFF
Keypad Backlit Always ON
Keypad Backlit Automatic OFF| 7 0#
7 1# (factory default)
7 2#
7 3# (factory default)
7 4 # 7 5# 7 6 # (factory default)
Automatic OFF after 20 seconds, it will go ON by pressing any key (this key isn’t taken into consideration)
3. Exit| *

Master Fingerprint/ Card Usage

Using Master Fingerprint/ Card to add and delete users

Add Fingerprint/ Card/ PIN Users| 1. Input (Master Fingerprint I Card)
2. Input (Fingerprint three times) or (Card) or (PIN#)
Repeat step 2 for additional users
3. Input (Master Fingerprint/ Card) again
Delete Fingerpnnt/ Card/ PIN Users| 1. Input (Master Fingerprint/ Card Twice within 5s)
2. Input (Fingerprint) or (Card) or (PIN #)
Repeat step 2 for additional users
3. Input (Master Fingerprint/ Card) again

Users Operation & Resetto Factory Default

Open the door Read valid user fingerprint or user card or input valid user PIN#
Remove Alarm: Enter Master Code# or Master Fingerprint/ Card or valid user fingerprint/ card / PIN
To reset to factory default &Add Master Card: Power off, press the Exit
Button, hold it and power on, there will be two beeps, then release the exit button, the LED light turns into yellow, then read any 125KHz EM card/ 13.56MHz Mifare card,  the LED will turn into red, means reset to factory default successfully Of the card reading, it is the Master Card.
Remarks:

  1. If no Master Card added, must press the Exit Button for at least 5 seconds before release.(this will make the previous registered Master Card invalid)
  2.  Reset to factory default, the user’s information is still retained.

CONTROLLER MODE

The device can work as Controller, connected with the external Wiegand reader.
(Factory default mode)— 7 7#
Connection Diagram

tienda MERY HF1 Outdoor FingerKey and Reader - paower
saply3

Attention: Install a 1N4004 or equivalent diode is needed when use a common power supply, or the reader might be damaged. (1 N4004 is included in the packing)
Set Wiegand Input Formats
Please set the Wiegand input formats according to the Wiegand output format of the external Reader.

Programming Step Keystroke Combination
1.Enter Program Mode * (Master Code) #
2.Wiegand Input Bit EM Card Version: 8 (26— 44) #

(factory default is 26bits)
Mifare Card Version: 8 (26— 44, 56, 58) # (factory default is 34bits)
3.Disable Parity Bit Enable Parity Bit| 8 0 #
81 # (factory default)
4.Exit| *

Note: For connecting Wiegand readers with 32. 40. 56 bits output, need disable parity bits.
Programming
> Basic Programming is the same as Standalone Mode
> There are some exceptions for your attention:
The device Connected with External Card Reader
– If EM/Mifare card reader: users can be added/deleted on either the device or external reader.
-If HID card reader: users can only be added/deleted on external reader.
The device Connected with Fingerprint Reader
For example:
Connect SF1 as the fingerprint reader to the device.
Step 1:Add the Fingerprint (A) on SF1 (Please refer to SF1 manual)
Step 2: Add the same Fingerprint(A) on the device:

1 Enter Program Mode: + (Master Code) #

1 (Press Fingerprint A once on SF1) # (ID auto allocated)
2
OR
1 (User ID)# (Press Fingerprint Aon SF1) # (Select specific ID)
2
3| Exit:

The device Connected with Keypad Reader
The keypad reader can be 4 Bits, 8 Bits (ASCII), or 10 Bits output format.
Choose the below operation according to the PIN output format of your reader.

Programming Step Keystroke Combination
1. Enter Program Mode * (Master Code)#
2. PIN input bits 8 (4 or 8 or 10) # (factory default is 4 bits
3. Exit *

Remarks: 4 means 4 bits, 8 means 8 bits, 10 means 10 digits virtual number.

Add PIN Users:
To add PIN users, after enter into programming mode on the device, PIN(s) can be input/ added on either the device or the external Keypad Reader.
Delete PIN Users: the same way as add users.

WIEGAND READER MODE

The device can work as Standard Wiegand Reader, connected to the third party
Controller –7 8 #
Connection Diagram

tienda MERY HF1 Outdoor FingerKey and Reader - fig2

Notes:

When set into Wiegand Reader mode, nearly all settings in Controller Mode will become invalid, and Brown & Yellow wires will be redefined as below:
– Brown wire: Green LED light control
– Yellow wire: Buzzer control
If you need to connect Brown/Yellow wires:
When the input voltage for LED is low, the LED will tum into Green; and when the input voltage for Buzzer is low, it will sound.

Set Wiegand Output Formats
Please set the Wiegand output formats of Reader according to the Wiegand input formats of the Controller.

Programming Step Keystroke Combination
1.Enter Program Mode * (Master Code) #
2.Wiegand output bits PIN output bits EM Card Version: 8 (26— 44) #

(factory default is 26bits)
Mifare Card Version: 8 (26— 44, 56, 58) # (factory default is 34 bits)
8 (4 or 8 or 10) # (factory default is 4 bits)
3 Disable Parity Bit Enable Parity Bit| 8 0 #
81 # (factory default)
4. Exit|

Note: For connecting Wiegand controller with 32. 40. 56 bits input, need disable parity bits.

ADVANCED APPLICATION

user Information Transfer (Valid for Card I PIN Users)
The device supports the User Information Transfer function, and the enrolled user (cards, PINs) can be transferred from one (let’s name it Master Unit) to another (let’s name it Accept Unit).

Connection Diagram:

tienda MERY HF1 Outdoor FingerKey and Reader - digaram

Remarks:

The Master units and Accept units must be same series devices.
The Master Code of the Master Unit and the Accept Unit must be set to the same.
Program the transfer operation on Master Unit only.
If the Accept Unit is already with the users enrolled, it will be covered after transfemng.
For full 900 users enrolled, the transfer takes about 30 seconds.
Set Transferring on Master Unit:

Programming Step Keystroke Combination
1. Enter the programming mode * (Master Code)#
2. Set transferring 98#

Within 30 seconds, Green LED shines, after one beep, the LED will turn into Red, which means the users’ information has been transferred successfully.
3. Exit| *

Interlock
The device supports the Interlock Function. It is of two Devices for two doors, and mainly used for banks, prisons, and other places where a higher level security is required.
Connection Diagram:

tienda MERY HF1 Outdoor FingerKey and Reader - paower
saply2

Remarks: The Door Contact must be installed and connected as the diagram.
Let’s name the two Devices as “A “and “B” for two doors “1” and “2” Step 1:
Enroll the users on Device A, then transfer the users’ information to Device B by “User Information Transfer” funciton.
Step 2:
Set both of the two Devices (A and B) to Interlock function

Programming Step Keystroke Combination
1. Enter Program Mode * (Master Code)#

2. Disable Interlock  OR
2. Enable Interlock| 90# (factory default)
91#
3. Exit| *

If enable interlock, when and only door 2 is closed, the user can read the valid fingerprint/card or input PIN on Reader A, door 1 will open; then when and only door 1  closed,read valid fingerprint/card or input PIN on Reader B, door 2 will open.

WiFi Access Controltienda MERY HF1 Outdoor FingerKey and Reader -
fig3

Introduction

This device is a WiFi based Touch Key Access Controller & RFID Reader People can install the mobile APP (TuyaSmart or Smartlife) to easily access the door with their  smartphone. The App supports 500 mobile users, and can manage 1000 users (Fingerprint/PIN /Card) maximum by the APP

APP Operation

Here are just a few steps to get you started.
1)Free App Downloading
Search TuyaSmart or Smartlife on Google Play or APP Store

2)Make sure WiFi works on your mobile phone.

Register & Login

(Make sure the registered email is legal and valid, so that you can recover your password once forgotten. Mobile Number is for China Mobile ONLY)tienda MERY HF1 Outdoor FingerKey and Reader -
fig4

You will get a verification code in your mail box

Add Device

You can add device by clicking ‘Add Device’or clicking ‘+’on the top.
(It is suggested to turn on the Bluetooth, it’s easier to find the device and faster to add device ) tienda MERY HF1 Outdoor FingerKey and Reader -
fig6

Note: To better manage the devices and family members, you will need to create a HOME before you begin to manage this device Attention: When the user first Open the lock through APP, APP will ask you to Switch on ‘remote unlock’ first

 Member Management

Note The first to add the device is the Home Owner (Super Master)

Authority Home Owner (Super Master) Administrator Ordinary member
Open the door
Member Management X
User Management X
Set Users as Admin X X
View All Records X
Set Relay Time X

User Management

4.1 Add Members
(Note. The members that you shared to must register the account first.)tienda MERY HF1 Outdoor FingerKey and Reader -
fig9

Remark: When adding members, the Owner (Super Master) can decide to add the user as Admin or Ordinary member
4.2 Manage Members
Owner(Super Master) can decide effective time (Permanent or Limited) of the members tienda MERY HF1 Outdoor FingerKey and Reader -
fig11(Same operation for Ordinary member)

4.3 Delete Members

tienda MERY HF1 Outdoor FingerKey and Reader - fig12

4.4Add Users (Fingerprint/ PIN/ Card Users)
The APp supports to Add/Delete Fingerprint/ PIN / Card users

Simplified Instruction

tienda MERY HF1 Outdoor FingerKey and Reader - fig23tienda MERY HF1 Outdoor FingerKey and Reader -
fig21

For adding PIN & Card users, same operation as adding Fingerprint user
4.5 Delete Users (Fingerprint/ PIN/ Card Users)

For deleting PIN & Card users, same operation as deleting Fingerprint user

Temporary Code

The temporary code can be shared by SNS tools (Whatsapp, Skype, Wechat. ) or email to the guest/users.
For Temporary Code. there are two types of it
Cyclicity For example, valid at 9:00am-6:00pm every Monday-Friday during
August–Octobertienda MERY HF1 Outdoor FingerKey and Reader -
fig20

Once: One-time code can be valid in 6 hours and can be used only for once tienda MERY HF1 Outdoor FingerKey and Reader - fig17

5.1 Edit Temporary Code

tienda MERY HF1 Outdoor FingerKey and Reader - fig18 The temporary code can be also deleted, editted or renamed in the valid period

Setting
6.1 Remote unlock setting
Default is off. When added the device first time, it will ask to turn on. Once turn off. all the mobile users will not be able to access the lock by APP
6.2 Automatick Lock
Default is on.
Automatic Lock on: Pulse Mode
Automatic Lock off. Latch Mode
6.3 Auto lock time
Default is 5 seconds. It can be set from 0-100 seconds.
6.4 Alarm lime
Default is 1 minutes. It can be set from 1-3 minutes.
6.5 Key Volume
It can set Key Volume Mute, Low, Middle and High.

Log ( Including Open History and Alarms)

tienda MERY HF1 Outdoor FingerKey and Reader - fig15

Remove Device & Reset Bluetooth Binding

tienda MERY HF1 Outdoor FingerKey and Reader - fig14

Note:
Disconnect is just removing the device from the App The users (card /fingeprirnt /code) are still retained (If Super Master Disconneted, all other memebers will have no  access to the device)
Disconnect and wipe data is unbinding the device and reset Bluetooth.
(Means this device can be connected by other new users)
Method 2 to reset the WiFi
(Master Code) # -Default Master Code is 123456
9 (Master Code)#
(To change the Master Code. please refer to another user manual)
ATTENTION:
There are 3features (Programming on the Device) that are NOT supported by the WiFi version

  1. Change PIN’
  2. Card+ PIN’ Access Mode
  3. Tips for PIN Security’ —- It supports to hide your correct PIN with other numbers up to a max of 9 digits only