tienda MERY Motores Tubulares Matic Persianas Aluminio Instruction Manual
- June 2, 2024
- tienda MERY
Table of Contents
tienda MERY Motores Tubulares Matic Persianas Aluminio
Warning:
- For your and others safety, please comply with the instructions.
- Please keep this manual in a safe place.
- This manual includes important safety precautions; the wrong insta llati on may cause very gerous consequences.
- Our S, M, R, C type motors are the driving force of device for shutter, screens, doors and wnings.
- Operating time is 4 mins.The appliance can not be restarted until temperature of motor ch to ambient.
- Please cho0se the right ones according with Nominal Torque and Max Runnin g time of the motor.
- Before installing the drive, remove any unnecessary cords and disable a ny equipment not needed powered operation.
- Any mechanical devices that not for running are prohibited for using.
Product Description
Our S, M, R, C type motors are all controlled by Mechanical Limit ,M s eries with a manual device, with built-in (external)receiver, C series with a clutch device. When the motor receive the signal,it each to the Iocation as be programmed, then the mechanical limit switch is triggered and motor will topped automa tically.
Structural Analysis and Model Interpretations
Structural Analysis
Model Interpretation
Installation
- Firstly,ensure the two ends bracket have been installed flatly, firmly.
- put the crown ring and adaptor in the motor,decrypted as below picture1.
- Insert the motor with the crown ring and adaptor into the aluminum tube ,ensure the crown ring and adaptor fitting the tube perfectly. expressed asp icture 2(When the tube is round, the adaptor must be settled with the tube by the screw. Checking the correct position before screwing, no damaging the motor’s out steel tube.
Notes:
- For installation for awnings, a horizontal distance of at least 0,4m is to be maintained between the fully unrolled driven part and any permanen t object.
- 1f the motor is used for driving awnings. Do not operate the awning when maintenance, such as Window cleaning, is being carried out in the vicinity.
- If the motor is used for shutter. During the operating. people need to watch the moving shutter and keep person away until the shutter is completely closed.
- If a manual release is provided, the actuating member is to be installed at a height less than 1,8m.
- How to use the manual release.
- When instal, fix the connector of the hand crank tie-in with forelock on t he transmission shaft
- when the power off or no current, hook up the hand crank on hand crank tie-in
- clasp the hand grip and rotate, then the motor can start running with loaded article.
Wire Connection
Limit adjustment
Tubular motor with a limit switch, when the shutter or awning reach to the
design ated position it will be switched off
automatically.
Adjust the limit, just drive two adjustment screws on the limit switch that
control th e Up”(stop at the top) and
down”(stopped at the low-end). Accoding to motor in nstalled on the
left(pic.1)or right side (pic.2), as well as shutter is
installed in side or outside to determine how to adjust screws.
“Up” adjustment
- Run the motor “up” direction (remote control buton ).
- Wait until the motor stop(limit switch triggered automatically)
- Comply with Tube running direction and using the adjust ploe to adjust at “+, “direction until reach the position you need (After adjusting, the motor will stop in the new position)
“Down” adjustment
- Run the motor “down” direction (remote control button ).
- Wait until the motor stops (limit switch triggered automatically).
- Comply with Tube running direction and using the adjust ploe to adjust at “+,-“direction until reach the position you need (After adjusting, the motor will stop in the new position).
Notes
- The power supply cable should not be exposed to sunlight or rain directly during installation.
- Frequently examine the installation for imbalance and sings of wear or dam age to cables springs. Do not use if repair or adjustment is necessary.
- Moving parts of the drive must be installed higher than 2.5 m above the flor or other level could provide access to it.
- Fixed controls have to be installed visibly
- Persons (including children) with reduced physical, sensory or mental capa b ilities, or lad experience and knowledge are not allowed to use this pro d uct.
Trouble Analysis
**No** | Trouble | **Cause of reason** | **Solution** |
---|
1
| Tubular motor can not run o startloo slowly and with big noise.| A. The voltageis toolow
B. Overload
C. Incorrect wireconnection
D. Wrong lnstallallon
| A. Adjust lo nominal voltage
B. Adjust lo max load torque
C. Check wire connection and corrector
D. Re-Installed the motor
2
| The motor Stopping running during working| A. Over the max working lime 4mms
B. LimllIs not set as the designated position
| A. Cool the molar for 15mins
B Adjust the limit switch to the designated position
3
| The shutter or awning running with no1sey| The out tube is too long, the shutter will be light with both sidebracket| Saw a little bit of out keep a distance between shutter and bracket
4
| After connecting with power. only one direction can work. the other direction can not work| The other direction’s switch Is closed|
Tum the crown ring on the dlrecho oppositeof the current working direction
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>