Thank you for purchasing the VCK LE-H006A Humidifier. Please read this user manual carefully and keep it for future reference. If you need any assistance, please contact our support team with your product model number and order number.

SAFETY INSTRUCTIONS

The humidifier was made with safe and environmental protection materials, it has been cerfified and complied with the requirement of sale regions’ related regulations or laws.
IMPORTANT: Please read and save this SAFETY INSTRUCTIONS before using the device. Basic precautions should always be followed fo reduce the risk of fire, electrical shock, and injury to persons or damage to the product.

BEFORE USING THE HUMIDIFIER

VCK 12AVC-US Ultrasonic Cool Mist Humidifier -
HUMIDIFIER

  1. A collision with a hard object may cause the product to rupture, please handle with care and do not hit the hard object.
  2. DO NOT place this humidifier in wet environments.VCK 12AVC-US Ultrasonic Cool Mist Humidifier - environments

Please always keep the humidifier out of reach of patients & children & pets.VCK 12AVC-US Ultrasonic Cool Mist Humidifier -
waterproof

  1. Please always place the unit on a smooth, flat, lint-free, non-metaliic, waterproof and level surface and keep it away from direct sunlight.

  2. Always place the unit 2 feet (60 cm) above the floor, 12 inches (30 cm) away from the wall, other appliances or wooden furiture.VCK 12AVC-US Ultrasonic Cool Mist Humidifier - damage

  3. DO NOT place the unit on carpet, fowel or wood surface, which wil block the vent and may damage the unit.

  4. DO NOT place the humidifier near naked flames and heat sources, such as stove tops, ovens, radiators or computers.

  5.  Please extend the cord and check any signs of damage. Do not use the humidifier if the cord has been damaged.

WHEN USING THE HUMIDIFIER

VCK 12AVC-US Ultrasonic Cool Mist Humidifier - hands

  1. DO NOT plug the unit with wet hands.
  2.  DO NOT direct the mist nozzle against the wall.

VCK 12AVC-US Ultrasonic Cool Mist Humidifier - cover

  1. DO NOT use your hand or any other object to cover the nozzle while the unit is on fo avoid damaging the product or causing injury.

  2. DO NOT clean the unit while it is connected to a power source or while it is on.VCK 12AVC-US Ultrasonic Cool Mist Humidifier - humidifier while it is in operation

  3. DO NOT move or tilt the humidifier while it is in operation.

  4. The most comfortable environmental humidity is between 40%-60%. Please adjust the mist as needed.

AFTER USING THE HUMIDIFIER

VCK 12AVC-US Ultrasonic Cool Mist Humidifier - AFTER USING THE
HUMIDIFIER

  1. Always disconnect from a power source by pulling the plug when not in use.
  2. Humidifier requires regular cleaning. Please refer to, and follow the Cleaning and Maintenance instructions.VCK 12AVC-US Ultrasonic Cool Mist Humidifier - Maintenance instructions

DO NOT attempt to repair or adjust any electrical or mechanical functions on this humidifier.

PACKAGE CONTENTS

  • 1 x Humidifier (Model: LE-HO06A)
  • 1 x User Manual

FEATURES

  1. Three-speed Mist adjustment
    Set your desired humidity level

  2. 360° Rotary Nozzle
    Turn the mist output toward any direction

  3. ULTRASONIC COOL MIST
    Stay cozy and comfortable whilst breathing properly all year round

  4. KNOB & DIGITAL SCREEN
    Easy to adjust the mist speed and set the fimer

  5. Auto Shut-Off Profection
    Stop working automatically when out of water

  6. 2.3L Transparent Water Tank
    Conveniently observe the surplus water at any fime

  7. Timer Function
    0-9 Hours timer settings for the appropriate working time

SPECIFICATIONS

Model No. LE-H006A
Power Supply AC 120V/60Hz
Power Consumption Max: 16W
Water Tank Capacity 2.3L
Working Time on A Full Tank 12 – 2411
Recommended Room Size 25m2/269ft2
Dimensions 210195253mm/ 8.267.679.96 inch
Mist Output Min: >100m1/h Max: >200m1/h

PRODUCT DIAGRAM

VCK 12AVC-US Ultrasonic Cool Mist Humidifier - PRODUCT
DIAGRAM

1. Mist Outlet 4. Sink 6. Operation Knob
2. Water Tank 5. Ultrasonic Disk 7. Power Cord
3. Water Lid

OPERATION AREA

VCK 12AVC-US Ultrasonic Cool Mist Humidifier - OPERATION
AREA

1. Work Icon 3. Number Icon
2. Timer Icon 4. Water Shortage Icon

OPERATIONS AND FUNCTIONS

VCK 12AVC-US Ultrasonic Cool Mist Humidifier - OPERATIONS AND
FUNCTIONS

Add Water

  1. Separate the tank from the base of the unit.
  2. Unscrew the tank lid
  3. Fill the tank with clean and cool water only.
  4. Attach the tank lid and place the tank back onto the base.
    Please make sure it fits fogether securely so that water can go from the tank to the reservoir.

Power On/Off

Plug the power cord into a wall socket. The icon
Now the humidifier is ready for use.

Plug the power cord into a wall socket. The icon “is shown on the display.
Now the humidifier is ready for use.

  1. Rotate the knob clockwise and the device starts o work.
  2. 1t has 3 mist levels and 9 hours fimer.
  3. Rotate the knob clockwise to “, the unit will shut down after the icon flashes threeTimes  and stays on for § seconds.

Mist Adjustment

  1. Rotate the knob clockwise to cycle display 3″, mist and close. 2″,”1″, ” mist levels, representing 3, 2, 1 gear of
  2. Stop rotating the knob and the level will be selected after the icon flashes three times.
  3. If you select ™”, the unit will shut down after the icon flashes three times and stays on for 5 seconds.

The most comfortable environmental humidity is between 40%-60%. Please adiust the mist as needed.

Timer Mode

  1. Rotate the knob counterclockwise to cycle display 0-9 hours timer.
  2. Stop rotating the knob and the fimer will be selected after the H icon flashes three times.
  3. When you set a fimer, the timer and the mist level are displayed altemately.

Auto Reduced Screen Brightness

The screen will stay on for 15 seconds and then reduce screen brightness automatically.
Water Shortage Reminder
When the water shortage icon flashes for 10 seconds, it turns to standby mode, and the screen turns off after 5 seconds.

CLEANING AND MAINTENANCE

Caution

  1. DO NOT submerge the base in water.
  2. Make sure water does not enter the base through the air outlet, air inlet or the control knob.
  3. DO NOT wash any part of this humidifier in the dishwasher which will damage the humidifier and void the warranty.

Daily Maintenance
After each use of the humidifier, pour out the remaining water and dry it before storage.

Weekly Maintenance

  1. To properly clean your humidifier, we recommend you remove the scale and disinfect the humidifier separately.
  2. DO NOT mix vinegar and bleach solutions together. Do not use more than 1 tsp. Of bleach per gallon of water to avoid damaging your humidifier.
  3. Please make sure the sealing ring on the tank cap s installed properly after cleaning to avoid water leakage.
  4. Clean and maintain the humidifier once it is used continuously for 3 days.
  5. When the humidifier is not used for a long time, it is recommended to dry the device before storage.
  6. Prepare a cotton swab/brush/mild defergent before cleaning.
  7. Please turn off the humidifier and unplug it before cleaning.

Cleaning The Water Tank

  1. Remove the water tank and pour out the remaining water in the device
  2. Rinse the inside and bottom of the tank with water.
  3. When there are water stains that are difficult fo remove, can add an appropriate amount of mild detergent to soak for 30 minutes and then clean them.
    Note: Do not use organic solvents, strong acids, strong alkalies and other substances for cleaning.

Cleaning The Sink
Please clean the sink with a damp cloth or brush.
Notice:
Itis not recommended to directly rinse the sink with water, fo avoid water splashing info the base from the air outlet, if water drips info the base, it will directly affect the normal operation of the product.
When cleaning the sink, if you accidentally drop water into the air outlet, do not plug in the device, and place the device on the front. Then let the water drain through the base drain hole.
And drain in the ventilated place for 3 days, until the water is fully evaporated before use.

TROUBLESHOOTING GUIDE

  1. If the information listed in the froubleshooting guide can’t solve your problem, please email us for help.
  2. Failure fo keep this unit clean from mineral deposits may affect operation of this unit.
  3. Customer failure to follow these instructions may void the warranty.VCK 12AVC-US Ultrasonic Cool Mist Humidifier - Valve
    Problem| Possible Cause| Solution
    ---|---|---
    LED indicator is off| Unit not plugged in| Ensure unit is properly plugged in
    No power from power outlet| Try another power outlet
    Did not turn on the unit| Check the Control Knob is turned to the working position.
    Water shortage icon lights up| The 1 valve was clogged, and the water cannot flow from the tank to the sink| Ensure the valve work, allowing water to pass through to the base
    The LED indicator is on but no mist or little mist is produced| Not enough water inside the tank| Refil and reinstal the water tank
    Mist level is set too low| Adjust to maximum mist
    Mineral buildup on the atomizer| Feel if any air comes out from the nozzle. If yes, then clean water scale on the atomizers instructed
    The base might be overfilled| Remove the tank, empty the base and place the filled tank on the empty base
    Tank leakage| Tank may be damaged| Check for possible cracks in the tank. if there is a crack, please contact our customer service to solve it.
    The lid of the water tank is not tightened| Check and tighten the lid of the tank
    Mist height is low, damping the surrounding desk or floor. Condensation forms around humidifiers or on windows and walls| Mist level is set too high for the room size| I. Check if the room is too
    humid and adjust to lower mist. 40%-60% works best
    2. Open door and windows or change to a larger room
    Air inlet is blocked| Humidifier should be placed on a hard flat surface, making sure no objects are around the air inlet.
    Low indoor temperature leads to liquefaction| Raise the room temperature to 25°C / 77°F
    Poor humidification| Mist level is set too low for the room size| 1.Adjust to maximum mist
    2.Close door or windows to reduce air ventilation, or change to a smaller room
    ---|---|---
    Air inlet is blocked| Humidifier should be placed on a hard flat surface, 2 feet above the floor, 12 inches away from the wall
    Low indoor temperature leads to liquefaction| Raise the room temperature to 25°C / 77°F
    White dust a ppears| Tap water may contain too much minerals| Replace with filtered or distilled water
    Strange odor| Clean the unit| 1.Clean the humidifier as instructed
    2.Leave the empty and opened water tank in a cool place for 12 hours without the tank cap attached
    Strange water noise| Water is going down to the water reservoir| This is normal while it is working
    Humidifier is getting too hot| Unit works for too long| Power off and place in a well-ventilated place for 10 minutes

WARRANTY & CUSTOMER SUPPORT

We offer a 12-month warranty.
For questions, support, or warranty claims, contact us at the address below that corresponds with your region. Please include your order number and product model number.
E-mail: support@vckhome.com
*Please note, VCK can only provide after sales service for products purchased directly from VCK. If you have purchased from a different seller, please contact them directly for service or warranty issues.

Ultrasonic Cool Mist Humidifier
E-mail: support@vckhome.com
MADE IN CHINA

Documents / Resources

| VCK 12AVC-US Ultrasonic Cool Mist Humidifier [pdf] User Manual
12AVC-US Ultrasonic Cool Mist Humidifier, 12AVC-US, Ultrasonic Cool Mist Humidifier, Cool Mist Humidifier, Mist Humidifier, Humidifier
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals