CDA-45563-TTS Pressure Injectable Arrowg+ard Blue Advance Three-Lumen PICC Instruction Manual
- June 4, 2024
- Arrow
Table of Contents
CDA-45563-TTS Pressure Injectable Arrowg+ard Blue Advance Three-Lumen PICC
Instruction Manual
-
Three Lumen TaperFree® Catheter with Arrowg+ard Blue Advance®
Antimicrobial/Antithrombogenic Protection1: 6 Fr. (2.11 mm OD) x 55 cm,
Pressure Injectable, Blue FlexTip®, Arrow® TipTracker™ Stylet and T-Port
Connector -
GlideThru™ Peel-Away Sheath: 6 Fr. x 2-3/4″ (7 cm) Radiopaque over 6 Fr.
Dilator -
Spring-Wire Guide, Nitinol, Marked: .018″ (0.46 mm) dia. x 17-3/4″ (45 cm)
(Straight Soft Tip on One End – Straight Stiff Tip on Other) with Arrow Advancer -
Injection Needle: Eclipse™2 25 Ga. x 1″ (2.54 cm) RW
-
Safety Introducer Needle: Echogenic 21 Ga. x 2-3/4″ (7 cm) TW
-
Introducer Needle: Echogenic 21 Ga. x 2-3/4″ (7 cm) TW
-
Syringe: 10 mL Luer-Lock
-
Syringe: 3 mL Luer-Lock
3: Dust Cap: Non-Vented -
SecondSite™ Adjustable Hub: Fastener
-
SecondSite™ Adjustable Hub: Catheter Clamp
-
SharpsAway® Disposal Cup
-
SharpsAway® II Locking Disposal Cup
-
Catheter Trimmer
-
Towel: 24″ x 36″ (61 cm x 91 cm)
-
Drape: 60″ x 76″ (152 cm x 193 cm)
-
Drape: 36″ x 41″ (91 cm x 104 cm) with 3″ x 5″ (8 cm x 13 cm) fenestration
-
Towel
-
Particulate Filter: 5 Micron Straw
-
Safety Scalpel: #11
-
Patient ID Card
-
Patient Information Booklet
-
2: Paper Tape Measure
-
Tourniquet
-
Foam Electrodes (3 per pack)
10: Gauze Pad: 2″ x 2″ (5 cm x 5 cm)
10: Gauze Pad: 4″ x 4″ (10 cm x 10 cm) -
Dressing: Tegaderm®3 15.5 cm x 10 cm
-
Surgical Apparel: Impervious Gown
-
Dressing: STATLOCK®4 Catheter Stabilization Device
-
Surgical Apparel: Mask with Eye Shield
-
Surgical Apparel: Bouffant Cap
-
Surgical Apparel: Mask
-
Equipment Cover: 13 cm x 244 cm (5″ x 96″)
-
Tape: Steri-Strip®3
-
HemoHopper® Fluid Receptacle
-
T-Piece Cover
-
Licensed under US Patent No. 7,329,412.
-
A trademark of Becton, Dickinson and Company.
-
A registered trademark of 3M Company.
-
A registered trademark of C. R. Bard, Inc.
All components are CE 2797 unless otherwise noted.
Not made with natural rubber latex.
Store below 25°C (77°F). Avoid excessive heat above 30°C (86°F).
Contraindications: The Pressure Injectable Arrowg+ard Blue Advance
antimicrobial/antithrombogenic catheter is contraindicated:
-
for patients with known hypersensitivity to chlorhexidine
-
in the presence of device related infection in the intended insertion vessel or catheter pathway
-
in the presence of thrombosis in the intended insertion vessel or catheter pathway
-
Priming volumes are approximate and are done without accessories.
† Flow rate values are approximate and are determined using deionized water at 100 cm head
height.
†† Pump flow rates are determined at maximum pump pressure of 10 psig and represent
approximate flow capabilities.
** Pressure injection flow rates are determined at the injector pressure setting of 300 psi maximum using media of 11.8 centipoise viscosity, with 152 cm pressure tubing.