  1. Three Lumen TaperFree® Catheter with Arrowg+ard Blue Advance® Antimicrobial/Antithrombogenic
  2. Protection1: 6 Fr. (2.11 mm OD) x 55 cm, Pressure Injectable, Blue FlexTip®
  3. GlideThru™ Peel-Away Sheath: 6 Fr. x 4″ (10 cm) Radiopaque over 6 Fr. Dilator
  4. Spring-Wire Guide, Nitinol, Marked: .018″ (0.46 mm) dia. x 17-3/4″ (45 cm) (Straight Soft Tip on One End – Straight Stiff Tip on Other)
  5. Guidewire, Marked: .018″ (0.46 mm) dia. x 130 cm Hydrophilic-Coated Nitinol with Soft Tip Tungsten Coil
  6.  Introducer Needle: Echogenic 21 Ga. x 2-3/4″ (7 cm) TW
  7.  Syringe: 10 mL Luer-Lock
  8. Skin Protectant Prep
  9.  Dust Cap: Non-Vented
  10. SecondSite™ Adjustable Hub: Fastener
  11.  SecondSite™ Adjustable Hub: Catheter Clamp
  12. Catheter Trimmer
  13.  Safety Scalpel: #11
  14.  Patient ID Card
  15. Chart Sticker
  16.  Patient Information Booklet
  17. Checklist/CLIP Sheet
  18. Paper Tape Measure
  19. Dressing: STATLOCK®2 Catheter Stabilization Device
  20. Licensed under US Patent No. 7,329,412.

Warning:
Read all package insert warnings, precautions, and instructions prior to use. Failure to do so may result in severe patient injury or death. www.teleflex.com/IFU

WARNING:
Cancer and Reproductive Harm. www.P65Warnings.ca.gov
Not made with natural rubber latex.Store below 25°C (77°F). Avoid excessive heat above 30°C (86°F). Fluid path components are non-pyrogenic.
Contraindications:
The Pressure Injectable Arrowg+ard Blue Advance antimicrobial/antithrombin biogenic catheter is contraindicated:

  • for patients with known hypersensitivity to chlorhexidine
  •  in the presence of device-related infection in the intended insertion vessel or catheter pathway
  •  in the presence of thrombosis in the intended insertion vessel or catheter pathway
  • Priming volumes are approximate and are done without accessories.
  • Flow rate values are approximate and are determined using deionized water at 100 cm head height.
  •  Pump flow rates are determined at a maximum pump pressure of 10 psig and represent approximate flow capabilities.
  •  Pressure injection flow rates are determined at the injector pressure setting of 300 psi maximum using media of 11.8 centipoise viscosity, with 152 cm pressure tubing.