INSERT INSTRUCTIONS
The Command Access MLRK1 is a field installable motorized latch-retraction kit for:
- MRLK1-DRX – Dorex 9500 series devices
Kit Includes
-
A. 1- Motor Mount
-
B. 1- 50944 – Molex Pigtail
-
C. 1- 50030 – 6’ Lead w/ VD Connector
-
D. 1- 10017 5/64″ Allen wrench
-
E. 2- 40064 – Phillips Screws
-
F. 2- 40060 – cable tie
-
G. 2- 40059 – mounting pad
-
H. 1- 60368/51186 – remote mm4s module
-
I. 1 – 50741 – remote module cable
installation video
SPECIFICATIONS
- Input Voltage: 24VDC +/- 10%
- AVERAGE low Torque LATCH RETRACTION CURRENT: 900 mA
- Average high torque latch retraction current: 2A
- Average holding current: 215 ma
- Wire gauge: Minimum 18 gauge
- Direct wire run – no relays or access control units in-between power supply & module
Recommended Power Supplies: Use a power limited class 2 power supply
All Command Access exit devices & field installable kits have been thoroughly
cycle tested with Command Access power supplies at our factory. If you plan on
using a non-Command power supply it must be a filtered & regulated linear
power supply
Technical Information
- Step 1 – Select your preferred torque mode (ships in standard torque) Press the device push pad to the desired setting. (Recommend to fully depress and release 5%, giving the device room for changing door conditions.)
- Step 2 – While depressing the push pad, apply power. (i.e. presenting the credential to the reader).
- Step 3 – Continue to keep pad depressed, the device will beep 6 times. After the beeps have stopped, release the pad and now the adjustment is complete. If not to your liking repeat the 3 steps.
Step 4- Once you found the correct location, turn PTS switch to OFF position.
Setting PTS
Troubleshooting & Diagnostics
Beeps | Explanation | Solution |
---|---|---|
2 Beeps | Over Voltage | > 30V unit will shut down. Check voltage & |
adjust to 24 V.
3 Beeps| Under Voltage| < 20V unit will shut down. Check voltage &
adjust to 24 V.
4 Beeps| Failed Sensor| Verify all 3 sensor wires are installed
correctly. Replace sensor if problem persists by contacting office.
5 Beeps| Retraction or dogging failure| After 1st fail : 5
beeps then immediately attempts to retract again.
After 2nd fail : 5 beeps with pause in-between for 30 seconds then device
attempts to retract again.
After 3rd fail : 5 beeps every 7 minutes, device will not attempt to
retract.
To Reset: Depress bar for 5 seconds at any time.
6 Beeps| PUSH TO SET| Device is recording it’s new position and
power mode after the 6th beep.
Installation Instructions
-
Flip over device & remove (4) screws securing push pad assembly to housing.
-
Slide Push Pad off Exit Device Housing.
-
Locate the FRONT Activating Bracket. Remove original mounting bracket by pushing out PIN.
-
Install Point of Front Activating bracket into opening of motor’s attaching knuckle. Depress activating bracket until the holes on the activating bracket & motor mount line up. Re-install factory pin.
-
Lift up Push Pad to 90 degrees & using the Allen Wrench to secure knuckle to front activating bracket.
-
Connect MM4S Cable to back of motor’s (3) Pin & (4) Pin connectors.
-
Slide Push Pad & Motor Kit back into housing. Be cautious of MM4S cable wires.
-
Flip Baserail/Pushpad over, holding motor kit in place so it stays attached. Secure Motor Kit with (2) M4 Screw provided.
-
Plug-in cable’s (4) Pin TOP port & (3) Pin BOTTOM port into MM4S ports.
-
Using double sided tape, secure MM4S to inside of the back of exit device housing. Connect Molex Pigtail. Add Mounting Pad & cable tie to secure cable wires.
-
Set the “Push to Set Adjustment” following the steps below.
- Setting PUSH TO SET (PTS)
Step 1 -Select your preferred torque mode (ships in standard torque)
Press the device push pad to the desired setting. (Recommend to fully depress
and release 5%, giving the device room for changing door conditions.)
Step 2 – While depressing the push pad, apply power. (i.e. presenting
the credential to the reader).
Step 3 – Continue to keep pad depressed, the device will beep 6
times. After the beeps have stopped, release the pad and now the adjustment is
complete. If not to your liking repeat the 3 steps.
Step 4- Once you found the correct location, turn PTS switch to OFF position.