OMRON E3ZS Single Beam Safety Sensor User Manual
- June 3, 2024
- Omron
Table of Contents
Single-beam Safety Sensor
E3ZS
For the most recent information on models that have been certified for safety standards, refer to your OMRON website.
E3ZS Single Beam Safety Sensor
Detects Intrusions into Hazardous Areas with a Single Beam and Complies with International Safety Standards.
**** Be sure to read the “Safety Precautions” on page 10.
Features
Can be Used as Safety Function of PLc/Safety Category 2 in combination with a Safety Controller (G9SP-series/NX-series Safety Control Unit).
Application Examples
For gaps in small-sized equipment
Can be used to protect personnel from the hazards of gaps in equipment or of
semi-automated machinery.
Make sure to connect the E3ZS to a safety controller conforming to related
standards when using it as a Human Body Detection Sensor (Type 2) to ensure
the safety of production facilities. Although the E3ZS by itself conforms to
PLc/Safety Category 1 (EN ISO13849-1), it cannot be used by itself in human
detection safety applications.
Ordering Information
Sensors
Red light
Sensor method| Appearance| Case material| Sheath material|
Connection method| Sensing distance| Output| Model
---|---|---|---|---|---|---|---
Through- beam
| |
Polybutylene terephthalate
|
PVC
|
Pre-wired cable (2 m)
| | | | |
PNP
|
E3ZS-T81A
| | 0.2 to 3 m
| |
Controller
Safety Controller G9SP Series
Name
| No. of I/O points|
Unit version
|
Model
---|---|---|---
Safety inputs| Test outputs| Safety outputs| Standard
outputs
Safety Controller
| 10| 4| Semiconductor outputs: 4| 4|
Ver.2.0
| G9SP-N10S
10| 6| Semiconductor outputs: 16| —| G9SP-N10D
20| 6| Semiconductor outputs: 8| —| G9SP-N20S
Note: For details, refer to the G9SP Catalog (F090).
NX-series Safety Control Units
Safety CPU Unit
Unit type
| Specifications|
Unit version
|
Model
---|---|---|---
Maximum number of safety I/O points| Program capacity| Number of
safety master connections| I/O refreshing method
Safety CPU Unit
| 256 points| 512 KB| 32| Free-Run refreshing|
Ver.1.1
| NX-SL3300
1024 points| 2048 KB| 128| Free-Run refreshing| NX-SL3500
Note: For details, refer to NX-series Safety Controller (EtherCAT System)
Catalog (Cat. No. F101) or NX-series Safety Controller Stand-alone
System brochure (Cat. No. F100).
Safety Input Units
Unit type
| Specifications| ****
Unit version
| ****
Model
---|---|---|---
Number of safety input points| Number of test output points|
Internal I/O common| Rated input voltage| Number of safety
slave connections| I/O refreshing method
Safety Input Units| 4 points| 2 points| Sinking inputs (PNP)| 24 VDC| 1| Free-
Run refreshing| Ver.1.1| NX-SIH400
Note: For details, refer to NX-series Safety Controller (EtherCAT System) Catalog (Cat. No. F101) or NX-series Safety Controller Stand-alone System brochure (Cat. No. F100).
Accessories
Sensor Mounting Bracket (for E3ZS)
Appearance | Model |
---|
| **E39-L104**
Mutual Interference Prevention Filter (for E3ZS)
Dimensions | Model | Quantity | Remarks |
---|---|---|---|
E39-E11 | 2 per Emitter and Receiver (4 total) | For use with E3ZS-T81A. This |
filter prevents mutual interference by changing the direction of polarized
light of the 2 adjacent Emitter/ Receivers. However, when the filter is
attached, the maximum
sensing distance of the E3ZS is reduced to 1.5 m.
Specifications
E3ZS
Item Model| E3ZS-
T81A
---|---
Sensor type| Through-beam models
Safety category| See Applicable standards.
Standard sensing object| Opaque object: 18 mm in diameter or greater
Lens diameter| Diameter 6.7 mm / diameter 9 mm
Sensing distance| 0.2 to 3 m
Response time (under stable light incident condition)| 1.0 ms (E3ZS
only)
Startup waiting time| 100 ms
Power supply voltage (Vs)| 12 to 24 VDC±10% (ripple p-p 10% max.) *1
Current consumption (no load)| Emitter: 15 mA max.
Receiver: 20 mA max.
Light source (emitted wavelength)| Red LED (660 nm)
Effective aperture angle (EAA)| ±5° (at 3 m)
Control output
| PNP transistor output, load current: 100 mA max. OFF current: 0.5 mA max.
Minimum current used: 1 mA
Residual voltage: 1 V max. (when load current is less than 10 mA)
Residual voltage: 2 V max. (when load current is between 10 mA and 100 mA) (except for voltage drop due to cable extension)
Output operation mode| Light-ON *
Input voltage| 22.5 to 24 VDC: Emitter OFF (source current: 3 mA max.)
Open or 0 to 2.5 V: Emitter ON (leakage current: 0.1 mA max.)
Indicators| Emitter: Emitting (orange)
Receiver: Operation (orange), Stable (green)
Test functions| External test (light emission stop function by test
input)
Connection method| Pre-wired cable (2 m)
Protective circuits| Power supply/output reverse connection protection,
load short-circuit protection
Ambient temperature
| Operating: -10 to 55°C Storage: -10 to 70°C
(with no icing or condensation)
Ambient humidity| Operating: 35% to 85%, storage: 35% to 95% (with no
icing or condensation)
Ambient operating light intensity| Incandescent lamp: 3000 lx max (light
intensity on the receiver surface). Sunlight: 10,000 lx max (light intensity
on the receiver surface).
Insulation resistance| 20 ML min. (at 500 VDC)
Dielectric strength| 1000 VAC 50/60 Hz 1 min
Degree of protection| IP67 (IEC standard)
Vibration resistance| Operating limit| 5 to 150 Hz, 7 mm double
amplitude/ 1 G acceleration, 10 sweeps for each X, Y, and Z directions (IEC TR
60721-4-3 Class 3M4)
Durability| 10 to 55 Hz, 1.5 mm double amplitude, 2 hours for each X, Y
and Z directions
Shock resistance| Operating limit| 15 G acceleration, 6 ms pulse
duration, 100 time for each direction of 3 mutually perpendicular axes (600 in
total) (IEC TR 60721-4-3 Class 3M4)
Durability| 500 m/s2 (approx. 50 G), 3 times for each X, Y, and Z
directions
Material| Case: Polybutylene terephthalate
Weight (packed state)| Approx. 120 g (for one set including 2-m cable)
Accessories| Operation manual
Applicable standards
| Sensor only| IEC 60947-5-3 (PDDB)
EN ISO13849-1 (PLc/Safety Category 1)
Sensor connected to safety controller| IEC(EN)61496-1 Type2 ESPE IEC (EN)61496-2 Type2 AOPD EN ISO13849-1 (PLc/Safety Category 2)
Note: Connect the Sensor to a safety controller conforming to related standards to use it as a safety device or as part of a safety system.
- Depending on the wiring, this may turn ON when light is interrupted.
For your safety, be sure to connect the pink receiver wire (mode selection input) to 24 VDC to turn ON when light is incident.
Connections
Circuit Diagram Example
Example of connection to G9SP
Note:
-
Only one E3ZS Single Beam Safety Sensor can be connected to a G9SP-series Safety Controller with unit version 1.0 or unit version 1.1.
The maximum number of E3ZS Single Beam Safety Sensors that can be connected to a G9SP-series Safety Controller with unit version 2.0 or later is as follows:
G9SP-N10S: 4 (1 Sensor ⋅ 4 systems)
G9SP-N10D/20S: 6 (1 Sensor ⋅ 6 systems) -
The total wiring length (L1 + L2 in the above figure) for the E3ZS Single Beam Safety Sensor must be 30 m or less.
-
The E3ZS Single Beam Safety Sensor can be used in a Safety Category 2 or lower, or PLc or lower application. It cannot be used in a Safety Category 3 or higher, or PLd or higher application.
-
If you use more than one Single Beam Safety Sensor, it may not be possible to detect short circuits between wires. To satisfy safety category 2, you must protect the cables to the Single Beam Safety Sensors from external damage. Use ducts, separate the cables for each system, or implement other measures to protect the cables from external damage when you connect the Single Beam Safety Sensors.
-
The test period for a Single Beam Safety Sensor test is as given below. Use the value as reference to determine conformance with standards for your system.
G9SP-N10S: 112 × Cycle time (ms)
G9SP-N10D/20S: 168 × Cycle time (ms)
Example of connection to NX-series Safety Control Unit
Example of Sysmac Studio Settings
Note:
-
The maximum number of connections per Unit is as follows:
NX-SIH400: 4 -
You can branch the connections to up to four Single-beam Safety Sensors for each Test Out-put.
-
Series connections are not possible.
-
The total wiring length for the E3ZS Single-beam Safety Sensors is 30 m max.
-
The E3ZS Single-beam Safety Sensor can be used in a Safety Category 2 or lower or PLc or lower application. It cannot be used in a Safety Category 3 or higher, or PLd or higher application.
-
If you use more than one Single-beam Safety Sensor, it may not always be possible to detect shorts between wires. Therefore, to satisfy safety category 2, the cables must be protected from external damage for connections to single beam safety sensors. Use ducts or separate cables for each system to protect the cables from external damage when you connect the Single-beam Safety Sensors.
-
The test period for a Single-beam Safety Sensor is 1,200 ms. Use this value for reference to determine the standard compliance of your system.
I/O Circuit Diagrams
Output mode: ON when light is incident (Light ON)
Timing Charts
1. When using in Safety Category 2 or Type 2 ESPE configurations, make sure all terminals on a safety controller are properly connected. See the safety controller operation manual for details.
2. Make sure to connect the pink wire (mode selection input) to 24 VDC.
*3. Make sure to connect to the 0V terminal when the E3ZS is not connected to a safety controller and the test input is not used.
Engineering Data
Dimensions
Sensors
Pre-wired Cable with ABS Resin Case
E3ZS-T81A
Accessories (Order Separately)
Sensor Mounting Bracket (for E3ZS) E39-L104
Safety Precautions
Indication and Meaning for Safe Use
WARNING| Indicates a potentially hazardous situatiowhich, if not
avoided, will result in minor moderate injury, or may result in serious injury
or death. Additionally themay be significant property damage.
---|---
Precautions for Safe Use| Supplementary comments on what to do or avoid doing,
to use the product safely.
Precautions for Correct Use| Supplementary comments on what to do or avoid
doing, to prevent failure to operate, or undesirable effect on product
performance.
WARNING
When the single beam safety sensor model E3ZS is used as a safety device or a
part of safety systems for ensuring safety of personnel, be sure to use it
with an appropriate safety controller.
WARNING
If the mode selection input (the pink wire) of the receiver is connected to
0V, the output turns ON when light is interrupted (Dark ON), which no longer
configures the safety system. Be sure to connect the mode selection input (the
pink wire) to 24V DC to make the sensor output ON when light is incident
(Light ON).
Always maintain a safe distance between the E3ZS and a hazardous part of a
machine. Be sure to refer to the related standards (ISO 13855) for the
calculation of safety distance.
Use an opaque test rod with 18mm in diameter and 200mm or greater in effective
length to check the detection capability. The E3ZS cannot detect transparent
materials.
Do not use the E3ZS in a reflective configuration, otherwise detection may fail.
Do not install the E3ZS in a location where it can be affected by wall
reflections to avoid detection failure, which may result in serious injury.
When using multiple sets of E3ZS, arrange them to prevent mutual interference.
Failure to do so may cause the sensor not to detect, resulting in serious
injury.
The E3ZS does not offer protection to the operator’s body from projectiles
existing the hazardous area. Proper means of mechanical guarding must be
provided to ensure protection from these potentially hazardous projectiles.
Wiring must be done while the power is turned OFF. Doing it with the power ON
may cause an electric shock.
Do not connect the E3ZS to an AC or DC power supply with higher voltage than
nominal DC24V. Otherwise the sensor may explode, burn, or cause electric
shock. The power supply must conform to regulatory requirements and standards,
regarding EMC and electrical equipment safety, of the country where the E3ZS
is installed. For example, the power supply must fulfill EN60742 requirements
for double insulation and must conform to EMC Directive and Low Voltage
Directive in EU.
To meet the Category 2, at least 100 diagnostic-tests must be undertaken
between two requests for a safetyrelated reaction from the E3ZS. For
diagnostic-test intervals, refer to user’s manuals of safety controllers to be
connected.
Precautions for Safe Use
-
When used in combination with a safety controller, also refer to the user’s manual of the safety controller for proper connection.
-
A load must not be shorted. A load must not be used with current higher than the rating. Do not apply the reversed supplied voltage. Be sure to route the E3ZS cable separated from high-potential power line or through an exclusive conduit.
-
Do not remove the label (yellow) from the sensor. Doing so may violate the specifications.
-
Wire the cable so that it has some slack and does not prevent personnel or object passage.
Allow some leeway for the wires and do not tight the wires when connection cable to G9SP, and confirm that any cable may not block the movements of workers or objects. -
Do not disassemble, repair or modify the E3ZS.
-
Be sure to dispose of the E3ZS as industrial waste.
Precautions for Correct Use
-
Do not install the E3ZS in the following environments:
• Areas exposed to intense interference light, such as direct sunlight;
• Areas with high-humidity where condensation is likely to occur;
• Areas exposed to corrosive, flammable or explosive gases;
• Areas in the presence of substances, such as heavy smoke or particulate matter, that may deteriorate product quality;
• Areas exposed to vibration or shock levels higher than specification provisions;
• Areas where the product may come in direct contact with water, oil, and chemicals; -
Do not install the E3ZS in water.
-
To extend the cable, use a wire of cross-sectional area 0.3mm 2 or more. However do not extend it more than 30 m.
-
Be careful not to exceed a tightening torque of 0.5 Nm. Also, if it is not tight enough, vibration may cause it to come loose.
-
When cleaning, avoid using thinner, benzene or acetone.
-
Power supply specifications
Do not connect to DC distribution network.
For combined DC power supply, use the following UL certified products:
(1) Limited voltage current circuit that conforms to UL508 Circuit with a power supply that consists of a secondary coil of an insulated transformer that satisfies the following conditions:
– Maximum voltage (with no load) : 30Vrms (42.4V peak) or less, and
– Maximum current :
1 BA or less (including short-circuit),
2 When limited by a circuit protector (fuse, etc.) with the ratings shown in the table belowNo-load voltage (V peak)| Maximum current rating (A)
---|---
0 to 20| 5.0
More than 20, up to 30| 100 Peak voltage value
(2) Class 2 power supply unit that conforms to UL1310
(3) Circuit (class 2 circuit) with 30Vrms (42.4V peak) or less of maximum
voltage, and which uses a class 2 transformer that conforms to UL1585 as its
power supply
- In a residential environment, this product may cause radio interference, in which case the user may be required to take adequate measures.
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please
consult your OMRON representative if you have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will
be free from defects in materials and workmanship for a period of twelve
months from the date of sale by Omron (or such other period expressed in
writing by Omron). Omron disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR
IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE
PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for
claims or expenses based on infringement by the Products or otherwise of any
intellectual property right. (c) Buyer Remedy. Omron’s sole obligation
hereunder shall be, at Omron’s election, to (i) replace (in the form
originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying
Product, or (iii) repay or credit Buyer an amount equal to the purchase price
of the non-complying Product; provided that in no event shall Omron be
responsible for warranty, repair, indemnity or any other claims or expenses
regarding the Products unless Omron’s analysis confirms that the Products were
properly handled, stored, installed and maintained and not subject to
contamination, abuse, misuse or inappropriate modification. Return of any
Products by Buyer must be approved in writing by Omron before shipment. Omron
Companies shall not be liable for the suitability or unsuitability or the
results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or
substances or environments. Any advice, recommendations or information given
orally or in writing, are not to be construed as an amendment or addition to
the above warranty.
See http://www.omron.com/global/ or contact your Omron representative for
published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR
CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY
WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT,
WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability
of Omron Companies exceed the individual price of the Product on which
liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards,
codes or regulations which apply to the combination of the Product in the
Buyer’s application or use of the Product. At Buyer’s request, Omron will
provide applicable third party certification documents identifying ratings and
limitations of use which apply to the Product. This information by itself is
not sufficient for a complete determination of the suitability of the Product
in combination with the end product, machine, system, or other application or
use. Buyer shall be solely responsible for determining appropriateness of the
particular Product with respect to Buyer’s application, product or system.
Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR
PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE
HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS
PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT
OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a
programmable Product, or any consequence thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is
provided as a guide for the user in determining suitability and does not
constitute a warranty. It may represent the result of Omron’s test conditions,
and the user must correlate it to actual application requirements. Actual
performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on
improvements and other reasons. It is our practice to change part numbers when
published ratings or features are changed, or when significant construction
changes are made. However, some specifications of the Product may be changed
without any notice. When in doubt, special part numbers may be assigned to fix
or establish key specifications for your application. Please consult with your
Omron’s representative at any time to confirm actual specifications of
purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to
be accurate; however, no responsibility is assumed for clerical, typographical
or proofreading errors or omissions.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
2022.10
In the interest of product improvement, specifications are subject to change
without notice.
(c)Copyright OMRON Corporation 2022 All Right Reserved.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>