Safety Information
Please read the following safety information carefully before operating the fixture. Information includes important safety information about installation, usage, and maintenance. Pay attention to all warning labels and instructions in this manual and printed on the fixture.

  • Keep this device dry.
  • For indoor use only.
  • Always connect to a grounded circuit to avoid the risk of electrocution.
  • Install only in a well-ventilated area.
  • Do not connect the device to a dimmer pack.
  • Make sure the power cord is never crimped or damaged.
  • Do not attempt to remove or break off the ground prong. The ground prong is provided for your safety.
  • Before connecting the fixture to power, always check the voltage indicated on the fixture matches your local AC voltage. Do not use the fixture if the AC power voltage does not match.
  • Disconnect the fixture from AC power before servicing and when not in use.
  • No user-serviceable and modifiable parts inside. Never try to repair this product, unauthorized repair may lead to fixture damage and/or malfunction.
  • Protect the power cord from being walked on or pinched, particularly at plugs.
  • Make sure there are no flammable materials close to the fixture while operating.
  • If the fixture fails to work, unplug the fixture and stop operation immediately. Contact your local Antari dealer for advice.

Unpacking and Inspection

Immediately upon receiving the fixture, carefully unpack the carton and check all content to ensure that all parts are present and have been received in good condition. If any parts appear damaged or mishandled from shipping, notify the shipper immediately and retain the packing material for inspection.

What is included:

  • 1 x PM-1 Pan Motor
  • 1 x Power Cord
  • 1 x Omega Clamp
  • 1 x User Manual

Product Dimension
The product dimensions are not provided in the given text extract. Please refer to the complete user manual for detailed product dimensions.

Product Overview

Setting Up:

  • Use the supplied mounting bracket or rigging clamp to install the fixture.
  • Make sure the installation location, fastening connecting, and rigging hardware can hold at least 10 times the weight of the fixture.
  • Make sure there are no combustible or flammable materials nearby.
  • Secure each fixture with an approved safety cable that can hold at least 10 times the weight of the fixture.
  • Make sure the fixture is installed in a well-ventilated area.
  • Consider lamp replacement and routine maintenance access when selecting the installation location.
  • Mounting: Use omega clamps for truss mounting.

Operation

Control Panel Operation:
The fixture can be operated with the onboard digital control interface.

Button Function
[MENU] Scroll through the settings menu
[UP] Move up in the menu
[DOWN] Move down in the menu
[ENTER] Setup/Confirm

Control Menu:

Address Set DMX address from 1 to 512
ChNd Set DMX channel mode 01 or 02
ShNd SPNd SLND LoSt Select auto chase pan movement: 60/90/120 degrees
ShNd SPNd SLND LoSt Select auto chase speed from 1 to 5
ShNd SPNd SLND LoSt Set fixture as Master/Slave 1/Slave 2
ShNd SPNd SLND LoSt When the DMX signal is lost, use this function to set the

fixture to
Master/Slave, Blackout, or run the last signal

Safety Information

Please read the following safety information carefully before operating the fixture. Information includes important safety information about installation, usage, and maintenance. Pay attention to all warning labels and instructions in this manual and printed on the fixture.

If you have questions about how to operate the fixture safely, please contact your local Antari dealer for help.

  • Keep this device dry. For indoor use only.
  • Always connect to a grounded circuit to avoid the risk of electrocution.
  • Install only in well-ventilated areas.
  • Do not connect the device to the dimmer pack.
  • Make sure the power cord is never crimped or damaged.
  • Do not attempt to remove or break off the ground prong. The ground prong is provided for your safety.
  • Before connecting the fixture to power, always check the voltage indicated on the fixture matches your local AC voltage. Do not use the fixture if the AC power voltage does not match.
  • Disconnect the fixture from AC power before servicing and when not in use.
  • No user-serviceable and modifiable parts inside. Never try to repair this product, unauthorized repair may lead to fixture damage and or malfunction.
  • Protect the power cord from being walked on or pinched particularly at plugs.
  • Make sure there are no flammable materials close to the fixture while operating.
  • If the fixture fails to work, unplug the fixture and stop operation immediately. Contact your local Antari dealer for advice.

Unpacking and Inspection

Immediately upon receiving the fixture, carefully unpack the carton, and check all content to ensure that all parts are present and have been received in good condition. If any parts appear damaged or mishandled from shipping, notify the shipper immediately and retrain the packing material for inspection.

What is included
  • 1 x PM -1 Pan Motor
  • 1 x Power Cord
  • 1 x Omega Clamp
  • 1 x User Manual

Product Dimension

Antari-PM-1-Pan-Motor-fig- \(1\)

Product Overview

Antari-PM-1-Pan-Motor-fig- \(2\)

Setting Up

AC Power Connection
This fixture includes an auto-sensing power supply ranging from AC100-240V, 50-60Hz. Only connect the fixture to AC power within this range.

Data Linking
Serial data links are required when operating the fixture through the DMX controller. When planning the data link please consider the following:

  • The maximum recommended length of a data link is 500 meters.
  • The maximum recommended number of data-linked fixtures is 32 units.
  • The fixture must be daisy-chained by linking the data output to the next data input.
  • Data output must be terminated on the last fixture of each chain using a termination plug.
  • Avoid long parallel runs of AC power and data cables as they may cause interference on the data link.
Physical Installation

Important

  • Use a supplied mounting bracket or rigging clamp to install the fixture.
  • Make sure the installation location, fastening connecting, and rigging hardware can hold at least 10 times the weight of the fixture.
  • Make sure no combustible or flammable material is nearby.
  • Secure each fixture with an approved safety cable that can hold at least 10 times the weight of the fixture.
  • Make sure the fixture is installed in a well-ventilated area.
  • Consider lamp replacement and routine maintenance access when selecting the installation location.
Mounting

Use omega clamps for truss mounting

Operation

Control Panel Operation

The fixture can be operated with an onboard digital control interfaceAntari-
PM-1-Pan-Motor-fig- \(4\)

Button Function
[MENU] Scroll through the setting menu
▲ [UP] Up
▼ [DOWN] Down
[ENTER] Setup/Confirm
Control Menu
  • Addr Set DMX address from 1 to 512
  • ChNd Set DMX channel mode 01 or 02
  • ShNd Select auto chase pan movement 60/90/120 degrees
  • SPNd Select auto chase speed from 1 to 5
  • SLND Set fixture as Master/Slave 1/Slave 2
  • LoSt When the DMX signal is lost, use this function to set the fixture to Master/Slave, Blackout, or run the last signal
  • Pan Turn on or off pan inversion
  • LeD Turn on or off display auto shut off
  • DISP Turn on or off display inversion
  • Test Activate self-testing mode
  • FhrS Show fixture running an hour
  • Uer Show software version
  • RSet Reset fixture to the factory default setting

DMX Connector Pin Assignment
The fixture provides 3 3-pin XLR connectors for DMX connection. The diagram below indicates pin assignment information

Pin Function
1 Ground
2 Data-
3 Data+

DMX Operation
Making DMX connection – Connect the machine to a DMX controller or to one of the machines in the DMX chain. The machine uses a 3-pin XLR connector for DMX connection. The connector is located at the back of the fixture.

Antari-PM-1-Pan-Motor-fig- \(8\)

channels. The starting address is defined as the first channel from which the fixture will respond to the controller. Always double-check to make sure there are no overlapping channels in order to control the fixture correctly.

DMX Channel Function

Channel Mode Channel Value Function
1 1 Pan Movement 0-255 0 to 120 degrees
  2 Auto Chase 0-15 Off
16-31 Pan 60 Speed 1
32-47 Pan 60 Speed 2
48-63 Pan 60 Speed 3
64-79 Pan 60 Speed 4
80-95 Pan 60 Speed 5
96-111 Pan 90 Speed 1
112-127 Pan 90 Speed 2
128-143 Pan 90 Speed 3
144-159 Pan 90 Speed 4
160-175 Pan 90 Speed 5
176-191 Pan 120 Speed 1
192-207 Pan 120 Speed 2
208-223 Pan 120 Speed 3
224-239 Pan 120 Speed 4
240-255 Pan 120 Speed 5

Service and Maintenance

Important!
Smoke fluid residue, dust, and any excessive particle residue will degrade product performance, cause overheating, and damage the fixture. Damages caused by inadequate cleaning or maintenance are not covered by a product warranty.

Cleaning

  • Unplug the fixture from AC power before starting.
  • Use a vacuum or air compressor and soft brush to remove dust on components and vents.
  • Clean the fixture with a moist, lint-free cloth.
  • Never use alcohol or solvents.

Technical Specifications

Input voltage AC100-240V 50-60Hz
Power 11W
Pan 120 degrees
Control option DMX 512, Manual
DMX channels 1, 2
Operation DMX 512, 4-digit display with 4 buttons
Power connection IEC
DMX data connection 3-pin XLR
Housing Metal chassis with plastic cover
Protection rating IP-20 Indoor use only
Dimension L 169 x W 154 x H 150/5 mm
Dry weight 1.9 kg

© 2016 Antari Lighting and Effects Ltd.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals