easy Home EBT-089 Smart Basal Thermometer User Manual
- June 3, 2024
- EASY HOME
Table of Contents
- INTENDED USE
- BENEFITS OF THE EBT-089
- WHAT’S INCLUDED
- SETUP AND USE
- DATA STORAGE AND UPLOAD
- CHOOSING MEASUREMENT UNIT
- REMINDER SETTINGS
- CHARGING REMINDERAND OPERATION
- TROUBLESHOOTING
- MAINTENANCE & CLEANING
- TECHNICAL SPECIFICATIONS
- PREMOM APP SYMBOLS
- EXPLANATION OF SYMBOLS
- PRECAUTIONS
- WARNING
- WARRANTY
- DISCLAIMER
- EMC/FCC INFORMATION
- FCC ID:2ADNQBTA41CNBT
- Customer Support
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
easy Home EBT-089 Smart Basal Thermometer
INTENDED USE
The Smart Basal Thermometer with Blue Tooth function, Model No. EBT-089 is intended for the measurement and monitoring of women body temperature at home through Bluetooth ( BLE ) function transfer to the smart phone using the Premom App for the purpose of confirming ovulation.
BENEFITS OF THE EBT-089
- Upon setup, data auto syncs to the free Premom app.
- With your BBT data, Premom does auto charting for you.
- Premom analyzes your BBT with your other fertility information.
- Premom’s all-inclusive platform predicts your best conception chance.
- LED display makes reading easier in a dark environment.
- Extremely light weight, makes the measurement a comfortable experience.
- Accuracy of 0.09°F for temperature readings.
WHAT’S INCLUDED
- 1 Thermometer
- 1 User manual
- 1 Charging cord
SETUP AND USE
❶ Download the app
| Simply search “Premom” in the Apple App Store or the Google Play Store to
download and install the app.
---|---
❷ Create an account
Open the Premom app and create your account by clicking “Sign up!” and follow the instructions on the sign up pages.
Note : Completing as much of the information on the Signup Pages will help the app to track your fertility most accurately. These values are important so Premom app can use them to predict your ovulation.
- Date of Your Last Period
- Your Average Pertod Length
- Your Average Cycle Length
- Your Age
❸ Pairing the thermometer
Keep the thermometer close lo your smartphone while the connection is being
established.
Step 1: Tap on the app homepage and choose “Pair”.
Step 2: Start the pairing.
Step 3: Pairing is complete, and ready to use.
❹ Taking your temperature
Step1: Keep the smart thermometer near your bed. Make sure to take your basal body temperature each morning at the same lime for the best results.
Note: Take measurement immediately when you first awake in the morning before any activities because any activities may tend to increase your temperature which will cause inaccurate temperature measurement.
Step2: Upon waking, tum on the smart thermometer. Place the metal probe
under the tongue and dose the lips tight. Hold the thermometer in place until
you hear 2 short beeps, which indicates the completion of the measurement.
This usually takes 80 to 90 seconds.
The reading of the test result will then display on the thermometer for 60
seconds and then the thermometer will tum off automatically.
Stop3: Your measurement will automatically sync to your smartphone if 111s nearby, the Bluetooth is enabled, and the app is running in the background. Otherwise the reading will remain on the queue until next lime the thermometer connects to the app.
Note: When the ambient temperature/measured temperature is lower than 89.6″F,
the screen will display’ Lo’.
When the ambient temperature/measured temperature is higher than 109.4°F, the
screen will display ‘HI’.
DATA STORAGE AND UPLOAD
Memory stores up to 200 measurements on the device itself. After the thermometer is turned on, only the last measured temperature is displayed. To sync all temperature data to your account, enable the Bluetooth on your phone, open the Premom app, and turn on the thermometer. A popup of “connected” will show al the bottom of the homepage. Once the thermometer and app are connected, all the stored data will automatically sync to the app.
Note: If the temperature data fails to sync lo the app please check the connection status by pressing ” Device ” under “ Settings ” on the app. If the status Is “not connected double check the thermometer Is on and Bluetooth Is enabled on the app.
CHOOSING MEASUREMENT UNIT
Fahrenheit is the default unit. You may skip this selling if ºF is the right unit for you.
Step 1: Tap on the top left of the homepage of the Premom app and select “Settings”.
Step 2: Find the temperature units on the settings list, switch the temperature unit between ºC(Celcius) and ºF (Fahreneheit}, then turn on the thermometer.
REMINDER SETTINGS
Tap on the top left. of the home page, and select “Reminders” in the app. Here you can set reminder notifications for BBT (or urine tests like PDG and LH if you use them), PDG, LH Testing if you use them). The Premom app will send you reminders for you lo lake BBT or others like PDG and LH testing if either of those are something you also use.
CHARGING REMINDERAND OPERATION
❶ When you see a red indicator flashing after the thermometer is switched on,
it indicates low power. Please stop using and charge ii immediately.
❷ Use the Micro USB cable in the package and the adaptor from your smartphone
to charge the thermometer. A yellow indicator will flash while charging is in
progress.
❸ When the indicator turns green, charging is completed and the thermometer
is ready for use.
Note :
The full charging time is about 1 hour. Do not use the thermometer during
charging. After the thermometer is fully charged, it can be used once a day
for about 60 limes.
TROUBLESHOOTING
- Unable to switch on the thermometer Please charge the thermometer for at least 1 hour.
- Unable to pair the thermometer with PREMOM APP Please make sure the Bluetooth of your mobile phone is enabled and the thermometer is on al the same lime. If ii fails lo connect, restart the phone and try again.
- App unable to connect with the device Possible Solutions: Make sure the Bluetooth is enabled on your smart device. Reboot the smartphone if necessary.
- Unstable body temperature data When taking your temperature, please follow the measurement instruction 3.4 very closely.
- High basal body temperature Please make sure lo measure immediately after waking up. The mouth has to keep closed for at least 5 minutes before measurement.
Do not exercise, eat or speak before taking the measurement. Otherwise your basal body temperatures might fluctuate a lot.
Note : If you still cannot get an effective solution, please contact Premom customer service by phone or email.
MAINTENANCE & CLEANING
- This thermometer is NOT waterproof. Clean it every time with alcohol Prep Pads before and after every use.
- Never submerge the thermometer into water or any other liquids. Keep ii away from direct sunlight and heat.
- Do not use cleansing and disinfecting agents other than water and alcohol to dean the probe. GD Do not sterlize the thermometer by high temperature, high pressure or soaking methods.
TECHNICAL SPECIFICATIONS
-
Product Size: 120rrvn x 20rrvn x 20rrvn
-
NetWeight:21g
-
Measuring Range: 89.8″F – 109.2″F (32.0″C – 42.9.C)
-
Accuracy: ±0.18′ FI 0.10’C (from 95.0’F to 102.2′ F/ 35″C-39″CJ ±0.36″F/ o.2o·c (from 89.6″F to 95.0′ F/ 32’C-35′ C, and from 102.2’F to 109.4″F/39’C-43’C)
-
Laboratory accuracy: ±0.09′ F/ ±0.0S”C (from 95.00″F to 102.20″FI 35.00′ C-39.00″C) ±0.18′ FI ±0.1o·c (the rest temperature)
-
Display Resolution: 89.6″F-109.2°F (32.00-C- 42.99″C)
-
Temperature Unit: Fahrenheit “For Gelsius ·c
-
Operating Condition:
-
Temperature: 41 “F – 104.F(5·c- 40″C)
-
Humidity: 15%- 85%RH
-
Storage Condition: Temperature: – 4·F -131·F (- 2o·c – 55·c)
-
Humidity: !i 85%RH
-
Lifetime:5years
-
Battery Model: 4.”N Lithium Battery
-
Applicable Mobile Devices:
IOS System: Supports iPhone SS and above, the operating sY5tem requires iOS11 and ebove; -
Android System: Supports common models with the operating syiitem Android4.4 and above.
PREMOM APP SYMBOLS
| Paired with thermometer, not connected
---|---
| Paired with thermometer and successfully connected
| User Profile/ Slide Menu for Settings/ Syncing
| Temperature Log/Pairing
EXPLANATION OF SYMBOLS
| Batch Code
---|---
| Manufacturing Date
| WEEE(Waste Electrical and Electronic Equipment)
| Type BF Applied Part
| Refer to instruction manual
| RF transmitters
| Ingress protection rating
| Bluetooth
| Humidity limitation of 0% – 85%
| Temperature limit of – 4″F -131’F(- 2o·c – 55’C)
PRECAUTIONS
- Do not bite, bend, drop or take apart the thermometer.
- Keep the device out of the reach of children/pets to avoid inhalation or swan owing of small parts.
- Do not expose it to direct sunlight, high temperature and moisture.
- Not intended to be sterilized. Prevent saliva or cleaning solution from penetrating the display window.
- Clean the thermometer after of before use with alcohol Prep Pads and soft cloth and store in cool place.
WARNING
- No servicing/maintenance while the thermometer is in use.
- Not for use in an OXYGEN RICH ENVIRONMENT.
- Before every use, check the device. Do not use the device if it is damaged in any way. The continuous use of a damaged unit may cause injury, improper results, or serious danger.
- If you have any problems with this device, such as setting up, maintaining or using, please contact with easy@home customer service.
- Never attempt to open or repair the thermometer.
- The main material of the shell is ABS. Pay attention to the potential allergic reactions to these materials.
- Protection against electric shock: Internally powered ME equipment.
- Protection against harmful ingress of water or particulate matter: IP22.
WARRANTY
- This product is warranted from manufacturing defects for one year from the date of retail purchase. It does not cover damages or wear resulting from an accident, misuse, abuse, commercial use, or an unauthorized adjustment or repair of the product.
- Please direct an returns to the place of original receipt, and you may be asked to provide proof of purchase. To find the customer service menu, please visit our official website at ww.premom.com
DISCLAIMER
This thermometer is not a medical device and is only used for fertility tracking.
NOTE: As we are constantly improving and updating the Premom app to offer the best user experience for our customers, the interface may be different from the illustrations included and all features mentioned should be available still and similar.
EMC/FCC INFORMATION
- This product needs special precautions regarding EMC and needs to be installed and put into service according to the EMC information provided, and this unit can be affected by portable and mobile RF communications equipment.
- Do not use a mobile phone or other devices that emits electromagnetic fields, near the unit. This may result in incorrect operation of the unit.
- Caution : This unit has been thoroughly tested and inspected to assure proper performance and operation I
- Caution : this machine should not be used adjacent to or stacked with other equipment and that if adjacent or stacked use is necessary, this machine should be observed to verify normal operation in the configuration in which it will be used.
Guidance and manufacture’s declaration – electromagnetic emission
The EBT-089 is intended for use in the electromagnetic environment specified
below. The customer or the user or the EBT-O89 should assure that it is used
in such an environment.
EMISSION TEST| COMPLIANCE| ELECTROMAGNETICENVIRONMENT
GUIDANCE
RF emissions CISPR 11| Group 1| The EBT-089 use RF energy only for its
internal function. Therefore, its RF emissions are very low and are not likely
to cause any interference in nearby electronic equipment.
RF emission CISPR 11| Class B| The EBT-089 is suitable for use in all
establishments, including domestic establishments and those directly connected
to the public low-voltage power supply network that supplies buildings used
for domestic purposes.
Guidance and manufacture’s declaration – electro magnetic
immunity
The EBT – 089 is intended for use in the electromagnetic environment specified
below.
The customer or the user of EBT-089 should assure that it is used in such an
environment.
IMMUNITY TEST| IEC80601 TEST LEVEL| COMPLIANCE LEVEL|
ELECTRO MAGNETIC ENVIRONMENT GUIDANCE
Electrostatic discharge (ESD) IEC 61000-4-2| ±6 kV contact
±8 kV air
| ±6 kV contact
±8 kV air
| Floors should be wood, concrete or ceramic tile. If floor are covered with
synthetic material, the relative humidity should be at least 30%.
Power frequency (50Hz/60Hz) magnetic field IEC 61000-4-8| 3A/m| 3A/m| Power
frequency magnetic fields should be at levels characteristic of a typical
location in a typical commercial or hospital environment.
NOTE: UT is the a.c. mains voltage prior to application of the test
level.
Guidance and manufacturer’s declaration – electromagnetic immunity
The EBT-089 is intended for use in the electromagnetic environment specified
below.
The customer or the user of the EBT-089 should assure that it is used in such
an environment.
| IEC 60601 TEST LEVEL| COMPLIANCE LEVEL| ELECTROMAGNETIC
ENVIRONMENT – GUIDANCE
Conducted RF IEC 61000-4-6
Radiated RF IEC 61000-4-3
| 3 Vrms 150 kHz to 80 MHz
3 V/m 80 MHz to 2.5 GHz
| Not Applicant
3 V/m
| Portable and mobile RF communications equipment should be used no closer to any part of the EBT-089, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter.
Recommended separation distance
Where P is the maximum output power rating of the transmitter in watts (W)
according to the transmitter manufacturer and d is the recommended separation
distance in metres (m).
Field strengths from fixed RF transmitters, as determined by an
electromagnetic site survey,
a should be less than the compliance level in each frequency range.
b Interference may occur in the vicinity of equipment marked with the
following symbol:
NOTE 1: At 80 MHz and 800 MHz, the higher frequency range applies.
NOTE 2: These guidelines may not apply in all situations.
Electromagnetic propagation is affected by absorption and reflection from
structures, objects and people.
a: Field strengths from fixed transmitters, such as base stations for radio
(cellular/cordless) telephones and land mobile radios, amateur radio, AM and
FM radio broadcast and TV broadcast cannot be predicted theoretically with
accuracy. To assess the electromagnetic environment due to fixed RF
transmitters, an electromagnetic site survey should be considered. If the
measured field strength in the location in which the EBT-089 is used exceeds
the applicable RF compliance level above, the EBT-089 should be observed to
verify normal operation. If abnormal performance is observed, additional
measures may be necessary, such as re-orienting or relocating the EBT- 089.
b: Over the frequency range 150 kHz to 80 MHz, field strengths should be less
than 3 V/m.
Recommended separation distances between portable and mobile RF communications equipment and the EBT-089.
The EBT-089 is intended for use in an electromagnetic environment in which
radiated RF disturbances are controlled. The customer or the user of the
EBT-089 can help prevent electromagnetic interference by maintaining a minimum
distance between portable and mobile RF communications equipment
(transmitters) and the EBT-089 as recommended below, according to the maximum
output power of the communications equipment.
Rated maximum output power of transmitter (W)| Separation distance
according o frequency of transmitter (m)
150 KHz to 80 MHz
| 80 MHz to 800 MHz
|
800 MHz to 2.5 GHz
0.01| 0.12| 0.12| 0.23
0.1| 0.38| 0.38| 0.73
1| 1.2| 1.2| 2.3
10| 3.8| 3.8| 7.3
100| 12| 12| 23
For transmitters rated at a maximum output power not listed above, the
recommended separation distanced in metres (m) can be estimated using the
equation applicable to the frequency of the transmitter, where Pis the maximum
output power rating of the transmitter in watts 0/V) according to the
transmitter manufacturer.
NOTE 1: At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.
NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people.
FCC ID:2ADNQBTA41CNBT
FCC compliance statement
-
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
• This device may not cause harmful interference.
• This device must accept any interference
received, including interference that may cause undesired operation. -
Changes or modifications not expressly approved by the party responsible for componence could void the user’s authority to operate the equipment.
-
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15ofthe FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.
-
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measure:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio! TV technician for help.
Customer Support
www.premom.com
Questions or comments?
Please call toll-free:
1-855-822-6999 M-F 9 a.m.-5 p.m. CST
E-mail: support@premom.com
Easy Healthcare Corporation
360 Shore Dr. Unit B, Burr Ridge, IL USA 60527
Made in China
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>