easy home FDTH-V0-13 Digital Clinical Thermometer User Manual
- May 15, 2024
- EASY HOME
Table of Contents
- easy home FDTH-V0-13 Digital Clinical Thermometer
- Overview
- What’s included
- Installation and measurement
- Display and sound tips
- Memory recall
- Low battery prompt function
- Clean and maintenance
- Product specifications
- Contraindications
- Safety Preca utions Measurement
- Warnings or precautions
- Troubleshooting instructions
- Battery Disposal
- Electromagnetic compatibility information
- Standards
- Warranty
- Explanation of symbols
- ABOUT COMPANY
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
easy home FDTH-V0-13 Digital Clinical Thermometer
Overview
The Easy@home Dual Digital Thermometer (FDTH-V0-13) is intended for the measurement and monitoring of human body temperature by consumers at home. The Dual Digital Thermometer has two modes – rapid read thermometer or basal body temperature (BBT) thermometer. In the mode of rapid read thermometer, the oral body temperature can be measured in about 8 to 12 seconds. When you feel unwell, you may use this mode to help you measure your body temperature quickly. The BBT thermometer mode is design to help measure BBT for ovulation tracking purpose.
Note:
- This product is only for monitoring body temperature, not for diagnosis of disease.
- You may use Premom APP to track BBT only if you use BBT thermometer mode.
What is Basal Body Temperature, and why do you need a digital basal
thermometer that has BBT thermometer mode to measure it?
Basal body temperature (BBT) is your temperature when you are fully at rest.
It is taken immediately upon awakening before any activity. Unlike traditional
thermometers, basal body thermometers can measure with increased accuracy to
easily detect your fertile window. The Digital Basal Thermometer is sensitive
enough to measure subtle changes in body temperature with the high accuracy of
±0.05’C (±0.10°F), and only takes about 60-120 seconds for the reading with
proper use in the BBT thermometer mode.
Note: It is important to record your temperature every day to identify
your BBT trend for ovulation prediction.
How does your Basal Body Temperature (BBT) help you pinpoint ovulation?
What do you need to know?
Your °BBT °temps will ° likely °surge right after ovulation, with a 0.20
C-0.60 C {0.40 F-1.00 F) or more increased shift. The free Premom app can
automatically chart your reading inputs and draw your coverline, a visual tool
to help you identify your basal body temperature shift. Premom allows
unlimited measurement storage in the cloud.
Note: Users MUST manually enter temperature in the Premom app with this
non-Bluetooth enabled model.
How to use the Premom app to help confirm ovulation?
- Tap the “Log BBT” button on the main screen.
- Choose “Manual” to log your Basal Body Temperature (BBT).
- Tap the degree area to enter your current numerical BBT and tap “Save”.
Note:
- To cha nge the time, tap the current time and scroll to the previous time and press save.
- If you would like to log the temp from a previous day, simply tap the arrow down a on the top of the screen, then choose the date and tap “Done”.
- If you would like to edit or delete a logged temp, just tap charts on the bottom of the main home screen. Tap “BBT” on the top of that next screen. After you access the table, swipe left and it will show you “Edit” or “Del” to proceed for a given temp.
Note:
- As we are constantly improving and updating the Premom app to offer the best user experience for our customers, the screen design or information may be different from the illustrations included but all features mentioned should be still available and similar.
- The Premom APP is only for tracking basal body temperature under the help of FDTH-V0-13 in BBT thermometer mode.
What’s included
- Thermometer * 1
- Manua l * 1
- Storage case “‘ 1
Installation and measurement
Product component
Installation of battery
- This thermometer uses a CR1632 battery which is pre-installed in the battery compartment.
- To replace the battery, turn counterclockwise with a Phillips screwdriver to remove the screw on the battery compartment cover.
- Carefully remove the cover, take out the old 1 battery, and replace it with a new battery of the same model.
- Follow the battery polarity mark in the battery compartment when making the rep!acement.
- Reinstall the battery cover and use a Phillips screwdriver to turn clockwise to tighten the fixing screw.
Switch measurement mode
- In the off state, press and hold the power control button for 6 seconds, until the screen shows #, then release the button to enter measurement mode setting.
-
Press the button to choose measurement mode. The ti shows on the screen means in BBT thermometer mode, while no this symbol means in rapid read thermometer mode.
-
After 3 seconds of no operation, the thermometer will automatically exit the mode switch setting and enter the measurement phase.
Note: The default measurement mode is BBT thermometer mode. When used as a basal thermometer, please make sure the proper mode is set.
Switch between Fahrenheit and Celsius
- When the thermometer is off, press and hold the button for 9 seconds until °F or °C display on screen. Keep holding the button, °C and °F will automatically switched every 2s. When the desired unit is displayed, release the button for confirmation.
- After temperature unit is confirmed, the thermometer immediately enters measuring mode.
Operating instructions
-
Disinfect the probe before each use with 70% ethyl alcohol.
-
Press the power control button to switch the device on.
-
Place the thermometer probe under the tongue and close the mouth tight. The thermometer probe should remain in constant contact with the tissue under the tongue, and the mouth should remain closed tightly during measurment. The average measurement time in BBT thermometer mode is 60-120 seconds, and in rapid read thermometer mode is about 8-12 seconds.
-
A long beep indicates that the measurement is complete.
-
If the thermometer is not operated for 30 seconds, it will auto power-off. Also, you can press the power control button to turn it off any time before 30 seconds.
Note:- Avoid eating, d rinking, or speaking before measuring the temperature, as this will result in an inaccurate temperature reading.
- When using the rapid read thermometer mode, if you move your body, talk, or eat, the measurement results may take longer than 8 seconds to appear.
Display and sound tips
When the measurement completes, the temperature unit (°F or ‘C) will stop flashing with a single beep sound indication. It is not recommended to measure basal body temperature (BBT) if the user may have a fever. If the measurement result exceeds 99.67°F or 37.60 °C1 you will hear three beep sounds in succession.
Memory recall
- When the thermometer is powered-off, press and hold the power button for 3 seconds, until the screen shows?, then release the button to enter memory recall mode.
- Press the power control button (the main button) to read the first reading In memory, press again to skip to the next one, and 30 readings in memory will be displayed in the cycle.
- Press and hold the button for 3 seconds to exit memory recal l mode and enter measurment mode. The thermometer will automatically power off after 30 seconds without any operation.
Low battery prompt function
- The thermometer automatically detects the battery charge every time it is turned on. When the battery voltage is low1 the icon appears on the display screen, which indicates the battery needs to be replaced by a new battery as soon as possible.
- When the battery icon appears in flashing, the thermometer will be forced to shut down in about 8 seconds.
Clean and maintenance
- Please use a soft, dry cloth to gently wipe the dirt on the mainframe. If the surface is more serious dirty, you can dip some alcohol to wipe. Cleaning is recommended every 1 month.
- Caution: Do not wash with water or use cleaners, diluents or volatile oils containing a brasives.
- After the thermometer measuring probe is soiled, please use a soft cloth dipped in more than 70% concentration of medical alcohol to cover the measuring probe end and gently wipe it. If the wipe is still not clean, please contact customer service.
- If the thermometer measuring probe, button, display and other parts are damaged, please contact the service.
- Do not put in direct sunlight, high temperature and humidity, dust, near the fire, vulnerable to vibration shock place custody
Product specifications
Statement: The product may not perform as claimed if stored or used outside the manufacturer’s specified temperature, humidity, and atmospheric pressure range.
Contraindications
Do not use the thermometer if you have oral lesions such as inflammation, trauma and postoperative. It is forbidden for those who are allergic to stainless steel and ABS plastic to use this product.
Safety Preca utions Measurement
- This product is only for monitoring body temperature, and cannot be used to diagnosis disease. It is very dangerous for customers to judge and treat themselves only by the results,so please follow the guidance of your doctor.
- To ensure the accuracy of the measurement, please set the thermometer in normal working environment for more than 30 minutes, so that it reaches the equilibrium state before measuring.
- Please do not measure under strong electromagnetic interference environment {working microwave oven, induction cooker, mobile phone nearby, etc.), this may cause incorrect measurement or the inability to measure.
- Users taking measurements after taking medications that change their body temperature (e.g. aspirin, acetaminophen, ibuprofen), which may cause measurement bias.
- The subjects may cause temperature fluctuations after intense exercise, crying, eating, etc. It is recommended to rest for 30 minutes before measurement.
- When measuring, please keep quiet and steady, according to the measurement method shown in this manual, so as not to cause the measurement deviation caused by improper operation.
- The slight fluctuation of human body temperature is normal, and the body temperature collected from different parts will also vary. It is recommended to measure and observe the body temperature in the same part of the mouth several times under similar condistions.
- Different thermometer brands cannot be compared. It is recommended to use the same thermometer brand to measure temperature to better know the temperature fluctuations.
- Keep new and used batteries out of the reach of children.Seek im mediate medical attention if a battery is ingested, and follow any other consensus medical advice from a trusted medical advisor.
- Choking Ha,ard-Small parts, not for children under 3 years or any individuals who tend to place inedible objects in their mouths.
Warnings or precautions
- Do not forcibly collide, drop, step on, or shake the product, as it may cause product failure or cause inaccurate measurements.
- Do not disassemble, repair, or modify the product by yourself.
- Do not use in electromagnetic interference environment, which may affect the measurement results.
- Please keep the product in accordance with the product transportation / storage conditions to avoid use problems or measurement abnormalities.
- If thermometer is not used for a long time, the battery should be removed to prevent battery lea kage or corrosion.
- Do not place this product in a place with electric shocks.
- Do not insert the metal probe end of the thermometer into the power socket. This may cause electric shock.
- Do not throw the thermometer and its accessory batteries into the fire, which may cause an explosion.
- Please dispose of waste or residue at the end of the product1s service life in accordance with local laws and regulations.
Troubleshooting instructions
Battery Disposal
Please dispose of the battery in accordance with your local law or regulation.
Electromagnetic compatibility information
WARNING:
- Use of this equipment adjacent to or stacked with other equipment should be avoided because it could result in improper operation. If such use is necessary, this equipment and the other equipment should be observed to verify that they are operating normally.
- Not use of accessories1 transducers and cables other than those specified or provided by the manufacturer of this the FDTH-V0-13 could result in increased electromagnetic emissions or decreased electromagnetic immunity of this equipment and result in improper operation.
- Portable RF communications equipment (including peripherals such as antenna cables and external antennas) should be used no closer than 30 cm (12 Inches) to any part of the FDTH-V0-13, including cables specified by the manufacturer. Otherwise, degradation of the performance of this equipment could result.
Guidance and manufacturer’s declaration – electromagnetic emission-for all EQUIPMENT AND SYSTEMS
Guidance and manufacturer’s decl aration – electromagnetic immunity for all EQUIPMENT and SYSTEMS
Guidance and manufacturer· s declaration – electromagnetic immunity for EQUIPMENT and SYSTEM that are not LIFE-SUPPORTING
Recommended separation distances between portable and mobile RF communications equipment and the EQUIPMENT or SYSTEM – for EQUIPMENT and SYSTEMS
Standards
FDTH-V0-13 complies with the following standards
Warranty
This product is warranted by the manufacturer for one year from the date of retail purchase. It does not cover damages or wear resulting from an accident, misuse or abuse, commercial use, or an unauthorized adjustment or repair of the product.
Explanation of symbols
ABOUT COMPANY
- www.premom.com
- Questions or Comments?
- E-mail: support@premom.com
- Distributed by: Easy Hea lthcare Corporation 360 Shore Dr., Burr Ridge, IL USA 60527 Man ufactured by: Famidoc Technology Co., Ltd . No. 212 Yilong Road, Hexi Industrial Zone, Jinxia, Changan Town, Dongguan 523853, Guangdong
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>