AMERICAN LIGHTING STL-WW-100 24V Trulux Single Color Standard Grade LED Tape Light Instruction Manual

June 3, 2024
American Lighting

AMERICAN-LIGHTING-logo

AMERICAN LIGHTING STL-WW-100 24V Trulux Single Color Standard Grade LED

Tape Light

AMERICAN-LIGHTING-STL-WW-100-24V-Trulux-Single-Color-Standard-Grade-LED-
Tape-Light-product

WARNING

  • These products may represent a possible shock or fire hazard if improperly installed or attached in any way. Products should be installed in accordance with these instructions, current electrical codes, and/or the current National Electric Code (NEC).
  • Use only 24V DC drivers with a wattage capacity that can handle the total load; see page 2 for more details. Factory warranty will be void if used with a non-recommended power supply, transformer or driver.
  • To reduce the risk of fire, electric shock or injury to persons, make sure that the electrical power to the system is disconnected at the source prior to installation or any servicing.
  • Never fold Trulux® or bend past the minimum bending radius of 1” whether lighted or unlighted.

LAYOUT CONSIDERATIONS

Pay close attention to the following maximum run lengths:

Series| Wattage| Cut Increments| Maximum run| Reel Length
---|---|---|---|---
STL Series| 2.19W/ft| 6.56”| 32.8 feet (71.8 watts)| 16.4 feet or 32.8 feet
HTL Series| 4.6W/ft| 3.94”| 22 feet (101.2 watts)| 16.4 feet
SPTLECO Series| 5.8W/ft| 2.8”| 16.4 feet (95.12 watts)| 16.4 feet
SPTL Series| 7.8W/ft| 1.97”| 13.1 feet (102.1 watts)| 13.1 feet
SPTLX Series| 7W/ft| 0.33”| 13.1 feet (91.7 watts)| 13.1 feet
VTL Series| 7W/ft| 1.4”| 13.1 feet (91.7 watts)| 13.1 feet

SAFETY INFORMATION

  • Read all installation instructions before beginning; if not qualified, do not attempt installation. Contact a qualified electrician.
  • To reduce the risk of fire, electric shock, or injury to persons, pay close attention to this manual and stay within its guidelines when using this product. Save these instructions for future use.
  • Do not cover this product with paper surface coverings, fabrics, streamers, or other similar combustible materials.
  • Do not operate Trulux on the reel, nor while it is coiled.
  • This IP54-rated tape light is suitable for indoor use in dry and damp locations, but not for direct contact with water or moisture. Do not submerge flexible light in liquids, or use the product in the vicinity of standing water or other liquids, or where water can accumulate.
  • Do not route the cord or tape light through walls, ceilings, doors, windows, or any similar part of the building structure.
  • Secure tape light using only the adhesive provided with the tape and/or factory-recommended mounting clips, mounting track, and aluminum channel (sold separately).
  • Do not secure this product or its cord with staples, nails, or like means that may damage the outer jacket or cord insulation.
  • Do not use if there is any damage to the tape light, diodes, or power cord insulation; inspect periodically.
  • Do not install on gates or doors, or were subject to continuous flexing.
  • Do not install airtight tanks or enclosures of any kind.
  • Size your 24V DC driver appropriately for your run distance. Be sure not to load a driver to 100% as this will reduce its efficiency; a 90% maximum load is recommended.

PRODUCT INFORMATION

IP54 reels include attached 3ft lead wires, (3) TL-BLKS connectors, (3) 4-in-1 connector kits (TL-CONKITs) which have 18AWG lead wire attached, and (3) TL- 2PWR-HD heavy-duty snap connectors with 6’ wires attached. Mount tape light using the 3M® VHB adhesive on the back of the tape. Once the VHB protective backing is removed, the tape should be placed on the prepared mounting surface and not be repositioned, removed, or re-used. For best results, let the adhesive cure 24 hours prior to first use.

Trulux® tape light utilizes nano-coating for ingress protection. It is recommended to scrape off the coating from each conductor to ensure a proper connection.

INSTALLATION INSTRUCTIONS

CUTTING & LINKING TRULUX® TAPE LIGHT (See Figures 2-7):
Do not exceed the maximum tape light run length in any single run. Cut increments are clearly marked on the tape light (see Layout Considerations on Page 1). Ensure an even cut along the center of the copper conductors to ensure enough surface area is exposed for snap connector pins to pierce through.

MAKING A TAPE-TO-TAPE CONNECTION (See Figures 3-5):

  1. Ensure the polarity of the conductors on the two pieces of tape light to be connected are aligned. See Figure 3.
  2. Using a tape-to-tape snap connector, open both sides of the connector so the metal teeth inside are exposed. See Figure 4.
  3. Peel a small portion of the protective backing from the tape light on the end to be connected, then insert cut tape light end so the copper pad conductors are aligned with the metal teeth inside.
  4. Close the snap connector and use pliers to ensure the connector “snaps” through the tape light. See Figure 5.AMERICAN-LIGHTING-STL-WW-100-24V-Trulux-Single-Color-Standard-Grade-LED-Tape-Light-fig- \(3\)

TO MAKE A TAPE-TO-WIRE CONNECTION (See Figures 6-9):

  1. Using a tape-to-wire snap connector, follow steps 1-4 from “Making a Tape-to-Tape Connection” above to connect tape light.
  2. Ensure the polarity of the conductors on the connected piece of tape light and the polarity of the wires align. See Figure 6.
  3. Cut the desired length of wire from the 15ft reel of wire including being sure to leave approximately 1/2’ on each end to be connected.
  4. Separate wires slightly so they fit in the grooves of the snap connector. There is no need to strip the wire. See Figure 7.
  5. Insert the cut wire into the slots of the snap connector so the wire is aligned with the metal teeth inside. See Figure 8.
  6. Close the snap connector and use pliers to ensure the connector “snaps” through the wire. See Figure 9.AMERICAN-LIGHTING-STL-WW-100-24V-Trulux-Single-Color-Standard-Grade-LED-Tape-Light-fig- \(4\)