CyberPower DTC36U12V3-G CyberShield User Manual

June 3, 2024
CyberPower

User’s Manual for CyberShield
DTC36U12V3-G

DTC36U12V3-G CyberShield

CyberShield UPSs are designed to provide a local power solution for cable telephony, wireless local loop (WLL), and fiber to the home (FTTH) broadband equipment. FTTx not only needs backup power to prevent utility power failure, but also supports making emergency calls (e.g., 911) for help.

IMPORTANT SAFETY WARNINGS
(SAVE THESE INSTRUCTIONS)

This manual contains important instructions regarding the installation and operation of this device. Read this manual thoroughly before attempting to unpack, install, or operate this device.
CAUTION! The battery can energize hazardous live parts inside even when the AC input power is disconnected.
CAUTION! To reduce the risk of fire or electric shock, install in an indoor area that both temperature and humidity could be controlled, and free of conductive contaminants. To find the acceptable ranges of temprature and humidity, please refer to the specification.
CAUTION! To avoid electric shock, unplug power cable from the AC power source before servicing the battery or installing a computer component.
CAUTION! To reduce the risk of electric shock, keep the cover on. There are no user-serviceable parts inside the unit. Please contact us or our dealer for service.
CAUTION! It is recommended to connect the unit to the required equipment and battery before plugging in the utility power.
CAUTION! The UPS battery is charging when it’s connected to utility power. The battery is charging during its first 24 hours of normal operation. Don’t expect full battery capacity during this initial charging period.
CAUTION! Runtime is based on testing fully-charged and new batteries at normal operating conditions. Runtime curve is approximate and varies based on battery age, level of charge at test, environment, and other variables.
CAUTION! Before replacing the battery, remove conductive jewelry, such as chains, watches
and rings. Use tools with insulated handles to avoid high energy, which could pass through conductive materials and cause severe burns.
CAUTION! Before replacing the battery, make sure the replacement has the same rating: Certified Valve Regulated Lead Acid Battery, 12V, 7.2Ah maximum.
CAUTION! The battery must be supplied by CyberPower. Using improper battery which is not evaluated with this model could cause a risk and is at the user’s own risk.
CAUTION! To store the UPS for an extended period, refer to the typical recharge time in the specification and recharge the battery every three months to ensure battery life.
CAUTION! The means of power cord should be connected to a socket-outlet with earthing connection.

OVERVIEW

Number Description
1 LED Indicator
2 Alarm Silence Button
3 Cold Start Button
4 Cable Retainer Installation Point
5 Communication Cable Connector
6 AC Power Cable Connector
7 Battery Cover

INSTALLATION

DESKTOP USE:

  1. Remove the battery cover at the back of the DTC36U12V3 and connect the battery wires.
  2. Connect the communication cable and simply place the DTC36U12V3 on or under a desk to begin backing up the optical home network.
  3. Plug the AC power cable into wall outlet.
  4. DTC36U12V3 desktop placement is shown as OVERVIEW illustration.

WALL MOUNT USE:

Step 1:
a. Use the enclosed installation paper template to mark the location of the screw holes used to mount the DTC36U12V3 to the wall.
b. Place the screws into the wall using and required anchors for a secure installation.
c. Place the round portion of the keyhole slots of the unit over the installed mounting screws.
d. Connect the battery connector carefully, reinstall the battery into the unit and secure the strap.
Step 2:
a. Connect the communication cable between the DTC36U12V3 and the ONT device.
b. Install the cable retainer to secure the commnication cable.

Step 3:
Connect the AC cable to the wall outlet.

BATTERY REPLACEMENT

As long as utility power is on, you may leave the UPS and connected equipment while replacing a new battery. (For service personnel reference only)

Step 1:
a. Slide off the battery cover at the back of the unit.

Step 2:
a. Remove the battery from the enclosure. b. Disconnect the battery cable connectors.

Step 3:
a. Replace with new battery and reconnect the battery connector. Make sure the red wire is connected to the “+” polarity, and the black wire is connected to the “-” polarity.
b. Slide the battery back into the compartment and cover the unit.

COLD START
The cold start feature is used when utility power is no longer present and a new or fresh battery is installed to support the load device. Once the new/charged battery is installed, depress the COLD START button until the 4 LED indicators light up.

BUTTON FUNCTIONS

Functions Instructions
Cold Start Press the COLD START button for 3 seconds.
Reset Output Press the ALARM SILENCE button for 20 seconds to turn off the

output power, and it will turn on automatically after 15 seconds.
Temporarily Alarm On/Off| Press the ALARM SILENCE button for 1 second to turn the alarm off for 24 hours. A short beep will occur to confirm the alarm is off.
Press the ALARM SILENCE button for 1 second again to restore the alarm. Two short beeps will occur to confirm the alarm is on.
Permanent Alarm On/Off| Press the ALARM SILENCE button for 15 seconds to turn the alarm off for permanently. A short beep will occur to confirm the alarm is off.
Press the ALARM SILENCE button for 15 seconds again to restore the alarm. Two short beeps will occur to confirm the alarm is on.

LED STATUS INDICATION

Indicator Color Light on Light off Blinking

SYSTEM
STATUS| Green| Normal operation| System fault Sy
(Output off)| N/A
DC| Green| Battery mode| Utility mode| Low battery
MUTE| Orange| Permanent alarm off| Alarm on| Temporarily alarm off
BATTERY| Red| Replace battery/ Battery missing| Battery OK| N/A

COMMUNICATION SIGNALS

The communication signals of this unit are isolated from the internal circuitry via open collector optocoupler transistors. The connection “SIG RTN” (Signal Return) is a return point for all communication signals. In the typical application, the connected equipment digital ground connects to Signal Return, and pull-up resistors turn the open collector signals into logic levels.

Pin Signal Message
1 12V + Voltage output
2 12 V RTN 12 Volt power return
3 SIG RTN Signal return
4 ON BATTERY Low when the UPS is in utility mode. Open when the UPS is in

battery mode.
5| REPLACE BATTERY| Low when the battery is in a normal state. Open when the battery needs to be replaced.
6| BATTERY MISSING| Low when battery is present.
Open when battery is missing or needs to be replaced.
7| LOW BATTERY| Low when battery has sufficient capacity. Open when the battery’s capacity is low.

SPECIFICATION

Model DTC36U12V3

Input
Voltage Range| 100 Vac – 240 Vac
Frequency Range| 50 – 60 Hz
Output
On Battery Output Voltage| 12 Vdc
Continuous Power Capability| 36 W
Efficiency (at Full Load, 25°C)| ≥ 80%
Battery
Battery Type| Sealed, Maintenance Free Lead-Acid Battery
Numbers of Battery| 12 Vdc / 7.2 AH   x  1
Typical Recharge Time (25°C)| 14 hours
Maximum Full Charge Time (25°C)| 36 hours
Replaceble| Yes
Surge Protection and Filtering
Lightning / Surge Protection| Yes
Management
Auto Charge| Yes
Physical
Dimensions (LWD)| 16.8 cm x 8.1 cm x 18.5 cm
Weight (with battery)| 3.13 kg
Environment
Operating Temperature|   – 4ºF – 113ºF (-20 ºC – 45ºC)
Operating Humidity| 0 – 95% noncondensing within enclosure
Max Operating Elevation| 10,000 ft (3,048 m)
Max Storage Elevation| 50,000 ft (15,240 m)
Storage Temperature|   – 4ºF – 113ºF (-20 ºC – 45ºC)

LIMITED WARRANTY

CyberPower warrants to you, the Initial Purchaser, that the Product will be free from defects in material and workmanship for three years from the date of original purchase, subject to the terms of this Limited Warranty. This Limited Warranty gives you specific rights, and you may have other rights, which vary from State to State and Province to Province.
Any Implied Warranty of Merchantability or for Fitness for a Particular Purpose, if applicable to the Product, is limited in duration to three years. This provision shall NOT create any Implied Warranty or Merchantability or of Fitness for a Particular Purpose that would not otherwise apply to the Product. NOTE: Some States and Provinces do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.
To be covered, you must be the owner of the Product at the time of the failure that results in the claim made under this Limited Warranty. Your sole and exclusive remedies are those provided by this Limited Warranty. This exclusion of other express warranties applies to written and oral express warranties. CyberPower excludes any liability for personal injury. CyberPower excludes any liability for direct, indirect, special, incidental, or consequential damages, whether for damage to or loss of property, loss of profits, business interruption, information or data. This exclusion applies even though damage or loss is caused by negligence or other faults. NOTE: Some States or Provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you.
DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT OR OTHER HIGH RISK ACTIVITIES.
CyberPower does not sell the Product for use in high-risk activities. The Product is not designed or intended for use in hazardous environments requiring fail-safe performance, including the operation of nuclear facilities, aircraft navigation or communication systems, air traffic control, weapons systems, life support or medical applications or for use in any circumstance in which the failure of the Product could lead directly to death, personal injury, or severe physical or property damage, or that would affect operation or safety of any medical or life support device (collectively, “High Risk Activities”).CyberPower expressly disclaims any express or implied warranty of fitness for High Risk Activities. CyberPower does not authorize the use of any Product in any High Risk Activities. ANY SUCH USE IS IMPROPER AND IS A MISUSE OF A CYBERPOWER PRODUCT.
The Limited Warranty is governed by the laws of the United States and the State of Minnesota, without reference to conflict of law principles. The application of the United Nations Convention of Contracts for the International Sale of Goods is expressly excluded.

FCC NOTICE
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and radiate radio frequency energy and, if not installed and used in accordance with these instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: (1) Reorient or relocate the receiving antenna. (2) Increase the separation between the equipment and receiver. (3) Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. (4) Consult the dealer or an experienced radio/TV technician for help.
CAUTION: Shielded signal cables must be used with this device to ensure compliance with Class B FCC limits.
CAUTION: Any changes or modifications which are not expressly approved by CyberPower could void the authority granted by the FCC to operate this equipment.

CAUTION: Batteries are considered HAZARDOUS WASTE , so they must be disposed of properly.
Most retailers that sell lead-acid batteries collect used batteries for recycling, as required by local regulations.
CAUTION: CyberPower Systems encourages environmentally sound methods for disposal and recycle of its UPS products.
Please dispose and/or recycle the UPS in accordance to the local regulations of your state.

WARNING: Cancer and Reproductive Harm-www.P65Warnings.ca.gov.

For more information, please contact:
CyberPower Systems ( USA ), Inc. 4241 12th Avenue East, Suite 400, Shakopee, MN 55379

Phone: (952)403-9500
Fax: (952)403-0009 cyberpowersystems.com
CyberPower Systems ( EUROPE ), Inc. Flight Forum 3545, 5657DW Eindhoven, The Netherlands E-mail: sales@cyberpower-eu.com eu.cyberpowersystems.com

All rights reserved. Reproduction without permission is prohibited.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals