CyberPower CPLI72D48V CyberShield Unit User Manual

June 3, 2024
CyberPower

CyberPower CPLI72D48V CyberShield Unit User Manual

OVERVIEW

Number Description
1 Output (Green)
2 On Battery (Yellow)
3 Fault (Red)
4 Silence Button
5 Cold Start Button
6 Input Connector
7 DC Output Cable
8 Battery Cover
9 Mounting Hole

BATTERY REPLACEMENT (FOR TECHNICIAN ONLY)

Follow these instructions carefully during the replacement of the battery.

UNPACKING

Check the CyberShield unit upon receipt. It should contain the following items:

  • CPLI72D48V unit
  • Lithium battery pack
  • User’s manual
  • Wall-mounted installation template

BUTTON FUNCTIONS

Button Functions Instructions

__

__

__

Silence

| Temporarily Alarm Off| Press the Silence button for 1 second to turn the alarm off for 24 hours. A short beep will occur to confirm the alarm is off.
Temporarily Alarm On| Press the Silence button for 1 second again to restore the

alarm. Two short beeps will occur to confirm the alarm is on.

Shut down| In battery mode, press the Silence button for 10 seconds to

shut down CPLI72D48V.

__

Reset

| In line mode, press the Silence button for 10 seconds to reset

output power and CPLI72D48V.

__

Cold Start

| __

Cold Start

| When utility power is no longer present and a new battery is

installed, press the Cold Start button to start CPLI72D48V.

LED STATUS INDICATION

Indicator Color Conditions
On Off Blinking
Output Green Output is normal
On Battery Yellow Battery mode
Fault Red Replace battery Battery missing

System error (Every 5 sec.)

AUDIO ALARM

Alarm Condition
1 long beep Transfer to battery mode
1 short beep every 15 minutes Replace battery/ Battery missing
4 short beeps every 1 minute Low battery
1 short beeps every 5 seconds System error
1 short beep Temporary alarm off
2 short beep Temporary alarm on

COMMUNICATION SIGNALS

The communication signals of this unit are isolated from the internal circuitry via open collector optocoupler transistors. The connection “SIG RTN” (Signal Return) is a return point for all communication signals. In the typical application, the connected equipment digital ground connects to Signal Return, and pull-up resistors turn the open collector signals into logic levels.

Pin Number Function Message
1 Power “+” + Voltage output.
2 On Battery Low when the unit is in utility mode.

Open when the unit is in battery mode.

3| Battery Missing| Low when the battery is present.

Open when the battery is missing.

4| SIG RTN| Signal return.
5| Power “-”| – Voltage output.
6| Replace Battery| Low when the battery is in a normal state.

Open when the battery needs to be replaced.

7| Low Battery| Low when the battery has sufficient capacity.

Open when the battery’s capacity is low.

8| No Use

SPECIFICATION

Model CPLI72D48V

Input
Voltage Range| 48 – 56 Vdc
Output
Output Voltage| 50 – 56 Vdc
Continuous Power Capability (Utility Mode)| 72 W
Max Power Capability (Utility Mode)| 80 W (<5 sec)
Continuous Power Capability (Battery Mode)| 40 W
Max Power Capability (Battery Mode)| 72 W (<5 sec)
Efficiency| >80%
Battery
Battery Type| Lithium Battery Pack (with thermal sensor)
Numbers of Battery| 2,200 mAh/14.4 V x 1
Typical Recharge Time| 5 Hours
Replaceable| Yes (technician only)
Warning Diagnostics
LED Indicators| Output, On Battery, Fault
Audible Alarm| Yes
Management
Auto Charge| Yes
Battery Pre-charge Function| Yes
Communication Interface| On Battery, Replace Battery, Battery Missing,Low Battery
Physical
Maximum Dimensions (LWD)| 16.5 x 9.6 x 4.7 (cm)
Weight (including battery)| 575 g
Environment
Operating Temperature| 23 ~131°F (-5 ~ 55 °C)
Operating Humidity| 0 ~ 95% noncondensing within enclosure
Max Operating Elevation| 10,000 ft (3,048m)
Max Storage Elevation| 50,000 ft (15,240m)
Storage Temperature| 23 ~ 131°F (-5 ~ 55 °C)