WATERWARE FWCU9507 Side Shower Installation Guide

June 3, 2024
WATERWARE

WATERWARE FWCU9507 Side Shower

FWCU9507 Side Shower

Installation Instruction

Installation Instruction Illustration

  1. Mark the center by extending 600mm upwards from the center of threaded tail. Place the fixing plate in the center and mark center position of holes. Drill two 6mm holes for masonry and tiled walls.
    Installation Instruction Illustration

  2. Press plastic plugs into holes, insert screws through the fixing plate and tighten firmly with a Phillips Head Screwdriver .
    Installation Instruction Illustration

  3. Apply Teflon tape to threaded tail and screw inlet adaptor onto threaded tail. Tighten firmly.
    Installation Instruction Illustration

  4. Slide the dress plate onto upper and lower pillar.
    Installation Instruction Illustration

  5. Push shower rail assembly onto mounting flanges. Tighten Grub Screws firmly.
    Installation Instruction Illustration

  6. Finished Work
    Installation Instruction Illustration

Notes
  1. Pressure rating:150-500kpa. If the pressure exceeds or is likely to exceed 550kpa, an approved pressure limiting device must be installed.
  2. Temperature rating: 1-75°C. If the water temperature exceeds 55°G, an approved tempering valve must be fitted.
  3. Flush out all pipes prior to installation.
  4. installation should comply with Australia standard AS/NZS3500 or relevant local authority requirements.
Maintenance and Care
  1. All products should be cleaned with mild detergent or soapy water by using a soft cloth or dampened sponge.
  2. Dry with a soft cloth after each use and clean regularly.
  3. Do not use any chemical or abrasive cleaners