GLOBAL INDUSTRIAL 412651 Heavy Duty LED Digital Crane Scale with Remote User Manual
- June 3, 2024
- GLOBAL INDUSTRIAL
Table of Contents
**GLOBAL INDUSTRIAL 412651 Heavy Duty LED Digital Crane Scale with Remote User Manual
**
Heavy Duty LED Digital Crane Scale W/Remote
Models: 412651, 412652, 412653, 412654, 412655
SPECIFICATIONS
Product Standard | GB/T11883-2017 |
---|---|
Accuracy Grade | Ill |
Zero Range | 100% Full Scale |
Time to Stable Reading | <10 Seconds |
Display Specifications | 5-digit Super High Brightness 25 mm red LED display |
Or 5-digit 20 mm FSTN LCD display with back lighting
Hanging Fixture| 360-degree swirl safe hook & shackle
Operating Temperature| -10°C — +40°C
Operating Humidity| 30%’° 90% RH
Auto Power Off| 30 minutes after the scale inactive or at extreme low power
supply
Internal circuit with
charging protection| To enhance the energy of battery and prolong its
performing life
Scale casing| Cast aluminum casing, corrosion safe, anti-static and light
weight
Keypad| Light touch keypad
The keypad includes On/Off, Units, Zero, and Hold.
( Note : The above keys can be used in sub-menu to set up lb-kg
conversion, Hold, Beeper On/Off, Zeroing and backlighting, etc.)
Max. Capacity | Division | Max. Capacity | Division |
---|---|---|---|
6000 lb | 1 lb | 3000 kg | 0.5 kg |
10000 lb | 5 lb | 5000 kg | 2 kg |
20000 lb | 10 lb | 10000 kg | 5 kg |
KEYPAD FUNCTIONS
- [HOLD] : Press this key to keep the current weight and there is a LED indication lamp on the bottom of the display window. Press this key again when the displaying weight flickers to cancel the HOLD function.
- [UNITS] : Press this key to change units between lb and kg.
- [ZERO] : Press this key to set the current weight to zero.
SCALE OPERATIONS
-
Turn on the Scale
Press the power switch located under the displaying window of scale. The scale’s maximum weighing capacity is first shown, and then the scale goes through a self-check sequence. 5 seconds later, the scale will stabilize and be ready for operation. (Note: it is recommended to allow scale 3~5 minutes of warm-up time before starting weighing operation). -
Zeroing
In default, the scale shows “0kg” or “0.0kg” after it is turned on. In case the display is showing numerical value other than “0”, press [ZERO] on the keypad or the remote to set the display to “0”. -
Weight Measurement
-
Once the load is suspended completely, the display show the weight value of the load. When the “Stable” indicator is lit, weight value can be recorded.
-
In case there is tare such as cable, load the tare and press [ZERO] to zero the display to “0”kg. The weight value after this will be the net weight. This will not change until the tare change or the scale being turned off.
-
Turn Off the Scale
After weighing operation, press the power switch to shut off the power completely to prevent the leakage of the battery.
BATTERY CHARGING INSTRUCTIONS
-
Then indicator will be on if there is low power. The battery needs to be charged now. The scale, however, can
continue to operate for about 5 hours without charging. -
After the indicator is ON for several hours without charging or there is no more power in the battery, the scale will be powered off automatically.
-
After battery charging, if there is no display, it indicates that either there is difficulty in battery charging or a damaged battery. To prolong the battery life, we suggest you charge the battery after using 48hours or no less than once per week. To avoid any damage to the battery, please charge it correctly. Additionally, we suggest you switch off the scale to shorten the charging time. The charging lamp on the displaying window and adaptor will turn red during charging. When the charging lamp on the adaptor becomes green, it means the battery is fully charged.
PRECAUTION
- Please charge the scale with standard charger.
- The load placed on the scale hook must not exceed the maximum weighing capacity of the scale.
- Perform routine inspection and maintenance to ensure operation safety for these basic items:
- Check for loose bolts.
- Check hook and shackle for deformation, wearing and tearing.
- Check other scale component for signs of metal fatigue.
- Check for missing hook latch.
- Avoid hitting, bumping the display window.
- Do not use the scale in the rain or heavily polluted environment.
- If the scale is not going to be used for some time, please clean it, remove the battery and store it in dry conditions.
CALIBRATION METHOD
Please do not attempt to calibrate the scale without standard weight
Step | Operation | Display | Remarks |
---|---|---|---|
1 | Press & Hold [ZERO] Key to power on | 0 | Input the password “****” |
2 | Press [ZERO] to confirm | SPAn | Enter Into setting state, and make sure the |
scale is with non-load.
3| Press [HOLD] Key| SEt
00000| It will display “00000” after S seconds.
4| Press [HOLD] Key to add Press [UNITS] Key to move the digit left| 3000|
Load the scale. The closer to full capacity the better. For example, 3000kg
5| Press [ZERO]| HOLd| The scale will record the new calibration data.
SETUP FUNCTIONS IN SUB-MENU
Function | Operation | Display | Remarks |
---|---|---|---|
Sets buzzer | Press (UNITS] during self-check sequence from “99999” to “00000” | ||
bEE 1 | 0: Disable |
1: Enable
Press (HOLD) or [UNITS) to change.
HOLD function| Press (ZERO)| Hod 1| 0: Disable
1: Enable
Press (HOLD) or (UNITS) to change.
Zero Function| Press [ZERO)| Stb 0| 0: zeroing allowed when unstable
1: zeroing not allowed when unstable Press [HOLD) or [UNITS) to change.
Backlighting setts!)| Press(ZERO)| Aut 1| 0: Manual 1: to Auto press (HOLD) or
[UNITS) to change.
Sets units| Press (ZERO)| CHt 0| 0: lb
1: kg
Press [HOLD) or (UNITS) to change.
Auto Power Off| Press [ZERO)| OFF 1| 1: Auto Power Off (after 30 minutes when
the scale in inactive)
0: shut off the auto power off
Save results| Press [ZERO)| YES 0| Automatic re-start
——————-| Press [ZERO)| | Automatic re-start
SCHEMATICS
Dimensions
unit : mm
Model | L | F | C | G | D |
---|---|---|---|---|---|
412651 | 683 | 80 | 60 | 176 | 52 |
412652 | 787 | 90 | 70 | 191 | 52 |
412653 | 787 | 90 | 70 | 191 | 52 |
412654 | 590 | 76 | 50 | 167 | 50 |
412655 | 590 | 76 | 50 | 167 | 50 |
REMOTE CONTROL
Fault analysis by checking the internal code
- 【Zero】: To zero the displaying weight.
- 【Hold】: Keep the current displaying weight and the indicating lamp will be lit.
- 【+/BL】: Turn on the backlighting. . (Only applies when the scale has a LCD display.)
- 【SW】: Change the division value between measured division and hi-resolution division.
Battery : 9V/6F 22 layer-built battery.
Note : Please extend the antenna before using the remote control.
ERROR INFORMATION
- ErrO: The calibration data should not less than 4 digits. Or the data will be invalid.
- Err1: The calibration data should not exceed the data 65536
- Err2; There is incorrect password to modify the calibration data.
- Err3: The weight value at the calibration point is too small. It should be no less than 3 valid digits
- Err4: Incorrect calibration password. Please input the correct password.
- Err5: The internal code at the calibration point is too small. The valid internal code is from 3000 to 65536.
Fault analysis by chedcing the internal code
Press (Zeroj to power on the scale, it will first show “Ad”. Then unpress the
key, it will show the internal code. If there is no load on the scale, the
internal code should be between 6000 and 8000. If the internal code is not in
the range from 6000 to 80130, please send the scale back to your supplier for
repair.