GLOBAL-INDUSTRIAL-436981-1000W-Pure-Sine-Wave-Portable-Power-Supply-
PRODUCT

Specifications

  • Model: 436981
  • 100 AH / 1000W Pure Sine Wave Portable Power Supply
  • Converts DC 12V Lead-Acid Battery to AC 100-120V/60Hz AC Voltage
  • Features: under-voltage protection, overload protection, power display, low-voltage prompt
  • Components: Main housing, Lead-acid battery, Charger, Inverter, Relay, American Standard power strip, Power display, 12V DC power supply, Heat dissipation fan

Product Usage Instructions

First Time Set-up Instructions

  1. Unplug the charging power cord before opening the unit.
  2. Remove the power cabinet cover.
  3. Open Casing by loosening Hex Screws using included Allen Key.
  4. Identify the battery wire terminals. Note that RED terminals correspond to the Positive (+) battery terminal.
  5. Insert bolt through Red (+) wire terminal. Place the flat washer, lock the washer, then bolt onto the battery terminal nut and tighten securely with wrenches.
  6. Insert bolt through Black (-) terminal. Be cautious of sparks; it is normal to spark for a first-time connection. Place the flat washer, lock the washer, then bolt into the nut and tighten securely with wrenches.
  7. Place the battery cover on and securely tighten Hex Screws.

Charging Instructions

Insert one end of the input line into the charging socket of the housing, and the other end into an external energy source, including wall outlets. Check that the input voltage is within 100-240VAC 50/60Hz.

Product Operation Steps

  1. Connect the device to the Power Strip on the housing.
  2. Turn on the power switch located on the front of the housing and the red button on the power strip IN THAT ORDER.

Maintenance Information

Avertissement: [Maintenance information goes here]

FAQ

Q: What should I do if the power display shows a low-voltage prompt?

  • A: If the power display shows a low voltage prompt, please check your battery connection and ensure it is securely fastened.

Q: How do I know if the overload protection has been activated?

  • A: If the overload protection is activated, the device will automatically shut off to prevent damage.
  • Allow it to cool down before attempting to use it again.
  • Converts the power of a DC 12V Lead-Acid Battery to AC 100-120V/60Hz
  • AC Voltage through an inverter to supply power to electric hardware.
  • This product has: under-voltage protection, overload protection, power display, and low-voltage prompt

Product Composition

  • This product is composed of Main housing, Lead-acid battery, Charger, Inverter, Relay, American Standard power strip, Power display, 12V DC power supply, Heat dissipation fan

Product Parameters

  • Overall Size: 17″ x 13.5″ x 13.5″
  • Weight: Net: 90lbs, Gross: 105lbs
  • Charging Input Voltage: 100-240VAC 50/60 Hz, 5A (max)
  • Load Output Parameters AC: 100-120V, 60Hz, 1000W
  • USB Output Parameters DC: 5V 2.1A
  • Charging time: 5hrs Full Charge
  • Operating Ambient Temperature: 32-104 °F
  • Power Display: 7 Bar Voltage and Percentage Display
  • Product Service Life: 1 year (Battery Deep Discharge: 300 Charge Cycles)
  • This product charges the internal lead-acid battery through the charger. After the battery is fully charged, the battery voltage (DC 12V) is converted to 100-120V AC through the inverter for output.
  • When the battery is fully charged, the charger will automatically protect the battery by disconnecting the charger plug, and the relay coil to the inverter is closed.
  • At this time, the inverter can be used with a load. During the use of this product, the power display shows the corresponding voltage prompt according to the power consumption proportion of the battery voltage.
  • When the voltage of the lead-acid battery is lower than 10%, a buzzer will start an alarm. When charging, the charger must be connected to an external power supply to charge the lead-acid battery.
  • During charging, the relay disconnects the lead-acid battery from the inverter. The inverter cannot supply a load while charging.
  • This product has over-load and over-current protection, as well as under-voltage protection and charging surge protection.

Warnings:

  • The voltage of each electrical appliance is different. Before using any device with this power supply, check whether the rated voltage range of the product is compatible with the output of the power supply.
  • Mis-matched voltage can cause damage and injury to the device, the power supply, and the user.
  • If the battery is discharged to the cut-off voltage, further discharge is called over-discharge. Over-discharging can easily cause severe loss of battery power and shorten battery life.
  • Avoid over-discharging the batter when in use by charging it once the cut-off voltage is reached.
  • Keep the battery away from fire, high temperatures, and humid or rainy environments during use and storage.
  • Do not disassemble the power supply. This item has a built-in high-voltage power supply.
  • Do not throw this power supply in general trash at the end of its life. Please recycle this item according to local laws and regulations.
  • The product’s casing should be effectively and firmly grounded before use.
  • Disconnect the charging power cord before removing the case lid to remove or replace the battery.
  • Disconnect the charging power cord before plugging any devices into the power supply.

Product Features Descriptions

GLOBAL-INDUSTRIAL-436981-1000W-Pure-Sine-Wave-Portable-Power-Supply-
FIG-1

First Time Set-up Instructions

Warnings: Unplug the charging power cord before opening the unit.

  1. Step 1: Open Casing by loosening Hex Screws using included Allen Key
  2. Step 2: Remove the power cabinet cover.
  3. Step 3: Identify the battery wire terminals. Note that RED terminals correspond to the Positive (+) battery terminal.
  4. Step 4: Insert bolt through Red (+) wire terminal. Place the flat washer, lock the washer, then bolt onto the battery terminal nut and tighten securely with wrenches.GLOBAL-INDUSTRIAL-436981-1000W-Pure-Sine-Wave-Portable-Power-Supply-FIG-5
  5. Step 5: Insert bolt through Black (-) terminal. Be cautious of sparks; it is normal to spark for a first-time, connection. Place the flat washer, lock the washer, then bolt into the nut and tighten securely with wrenches.
  6. Step 6: Place the battery cover on and securely tighten Hex Screws.

Charging Instructions

  • Insert one end of the input line into the charging socket of the housing, and the other end into an external energy source, including wall outlets.
  • Check that the input voltage is within 100-240VAC 50/60Hz.

Product Operation Steps

  1. Connect the device to the Power Strip on the housing.
  2. Turn on the power switch located on the front of the housing and the red button on the power strip IN THAT ORDER.

Maintenance Information

  • Charge fully before use, especially for first-time use.
  • Periodically clean dust and dirt from heat dissipation louvers.
  • Keep the housing dry and clean to protect the battery from discharging on its own.
  • Do not store the battery uncharged. If it is to be stored for a long time, it should be fully charged, placed in a cool and dry place, and recharged regularly.
  • At low temperatures, there can be issues of battery power loss caused by poor charging acceptance and insufficient charging.
  • Thermal insulation and anti-freezing measures must be taken at low temperatures, especially while charging.
  • The device should be kept in a warm environment to prevent irreversible sulfation.
  • Do NOT expose the product to moisture or water- Do not wash the product.
  • Customer Service US: 1-800-645-2986