GLOBAL INDUSTRIAL 293132 Evaporative Air Cooler Fan User Manual

May 15, 2024
GLOBAL INDUSTRIAL

GLOBAL-INDUSTRIAL-LOGO

GLOBAL INDUSTRIAL 293132 Evaporative Air Cooler Fan

Thank you for purchasing an Evaporative Air Cooler from Global Industrial.

Please Read These Instructions Carefully Before the Operation.

PACKAGE CONTENTS

  • 1 Evaporative Air Cooler Unit
  • 1 Remote Control
  • 1 Operating Instructions Manual

WARNING

  1. DO NOT Use an Extension Cord with this Fan.
  2. Check the outlet that this fan is plugged into for correct polarity before using the outlet.
  3. Do not open the control box compartment. No serviceable parts inside.
  4. All repairs must be done by an authorized technician.
  5. Disconnect the power cord before changing the media or opening fan housing
  6. DO NOT modify equipment or power cord; the Warranty will be voided.
  7. Test the GFCI breaker on the cord before each use of fan.

This product contains chemicals that are known to the State of California to cause cancer, birth defects, or other reproductive harm

ABOUT THE PRODUCT

The Evaporative Air Cooler is a high-tech product that utilizes water evaporation and movement air to cool the air. The cooler consists of a fan, a corrugated and fluted paper media pad and a water supply sump and water circulation system that maintains the saturation of the media. As the moisture in the moving air evaporates there is a cooling effect. The water level in the sump, if manually filled, can be monitored by the sight tube on the front of the housing. For constant automatic feed the water level is controlled by a float valve in the sump tank.

TECHNICAL SPECIFICATION

GLOBAL-INDUSTRIAL-293132-Evaporative-Air-Cooler-
Fan-FIG 5

FEATURES

  1. Micro-computer programmed control panel with LCD display.
  2. 3-speed fan operation
  3. Time setting function
    • Running Time
    • Starting Time
  4. Convenient remote control.
  5. Specially Designed 36″ diameter fan.
  6. Thick cooling pad measures
    • 60.9″W x 7.9″D x 50.4″H for improved heat absorption.
  7. 5″ rubber casters with brakes.

WARNING INFORMATION

Before operating the machine, Please read the instructions carefully.

Operate in the following conditions:

  1. 68-122°F Operating Temperature.
  2. MAX with 113°F Water Temperature.
  3. The area must be free from airborne pollutants and contaminants.
  4. Ventilated, Open environment with fresh air supply.
  5. Electric voltage must not exceed 115V +/- 5V voltage.

WARNING: Low Voltage less than 110V or High Voltage greater than 120V may cause damage to motor and electronic controls.

  1. DO NOT use a fan if the power cord is damaged.
  2. DO NOT drive forklifts, power trucks or any vehicle overpowering card
  3. If the product is not operating correctly, Please refer to the Troubleshooting Guide or contact Customer Service at 800-645-2986
  4. Any modification to fan will void the warranty.GLOBAL-INDUSTRIAL-293132-Evaporative-Air-Cooler-Fan-FIG \(1\)

CONTROL FUNCTIONS: Operate functions by pressing the button on the control panel

  1. Power “ON/OFF” switch.
  2. Press the “COOL” button to activate the cooling function. The water pump will circulate water into the cooling pad for one minute, then the fan will activate.
  3. Airflow Wind “SPEED” for desired airflow setting. (Low/Medium/High).
  4. “TIMER” button to set an automatic timer. Dual Timer.
    • The timer can be set to start in x hours.
    • The timer can be set to turn off in x hours.

SET-UP

WARNING

Unplug the fan before removing the media pad. Fan can start unexpectedly due to the timer control feature.

Before operating the machine, please follow the instructions listed below

  1. Add Water.
    • Clean water must be used.
    • Use the hose connection on the left side (Hose not included)
    • Manually add water through the water inlet opening on the right side.
    • Pour water slowly to avoid water spillage and prevent the risk of electric shock.
    • Fill up to the “MAX” level only.
  2. Plug the unit into a 115V/60Hz, Single phase outlet (Check outlet for correct polarity)
    • The power indicator will light up.
  3. NOTE: If the power cord is damaged, it must be replaced by the manufacturer or a qualified electrician to avoid hazards.

WARNING

on it is tal panned for a by happier and a with red, celes yale, se bery given supervision or instruction concerning use by a person responsible for their safety

To ensure the unit releases fresh and clean air, always change the water when dirty and regularly clean the cooling pad.

  1. Remove the filter by removing the screws and then pressing the lock.
    • Rinse the filter under running water to wash off dirt. DO NOT use a pressure washer.
  2. Pull out the cooling pad and wash both sides under running water.
    • NOTE: Never use pressurized water.
    • NOTE: Never use liquid detergent. This may damage the pad.
  3. Open the drainage valve to remove the remaining water, and then clean the water tank thoroughly with a soft cloth to remove dirt.
  4. Wash off dirt from the water sensor, water pump, and drainage valve.
  5. Use mild soap and soft, clean cloth when cleaning the housing and chassis.
    • NOTE: DO NOT Use strong chemicals when cleaning the unit.

TROUBLESHOOTING

NOTE: Instructions are for reference purposes only. If technical assistance is needed, Please call Customer service at 800-645-2986

Product Overview

GLOBAL-INDUSTRIAL-293132-Evaporative-Air-Cooler-Fan-FIG
\(2\)GLOBAL-
INDUSTRIAL-293132-Evaporative-Air-Cooler-Fan-FIG \(3\)

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

GLOBAL INDUSTRIAL User Manuals

Related Manuals