GLOBAL INDUSTRIAL 534802 IP54 OriginCal Absolute Digital Caliper Instruction Manual

June 1, 2024
GLOBAL INDUSTRIAL

GLOBAL INDUSTRIAL 534802 IP54 OriginCal Absolute Digital Caliper

GLOBAL-INDUSTRIAL-534802-IP54-OriginCal-Absolute-Digital-caliper-
product

Please read through this owner’s manual carefully before using the gauge. Use the tool properly and only for its intended use.

Item# Range Accuracy

  • 534802 0-6”/0-150mm 0.001”/0.02mm
  • 133790 0-8”/0-200mm 0.0015”/0.03mm
  • 133791 0-12”/0-300mm 0.0015”/0.03mm

Parts

GLOBAL-INDUSTRIAL-534802-IP54-OriginCal-Absolute-Digital-caliper-
featured

  1. Measure Beam
  2. SPC 5-PIN
  3. Data Port
  4. HD LCD Display
  5. Thumb Roll
  6. Function Keys
  7. External Measure Jaws
  8. Battery Compartment
  9. Internal Measure Jaws
  10. Depth Rod (rear)

Specification

  • Reading: 0.0005” / 0.01mm
  • Measuring speed: 3 meters per second
  • Protection rating: IP54 water splash and dust protection
  • Power: Battery 3V, CR2032; Storage temperature: 0-40°C
  • Operating environment: 0-40°C

Battery Replacement

  1. Slide the battery cover to the right
  2. Remove the battery rubber seal
  3. Pull out the battery tab for battery removal
  4. Insert a new CR2032 battery
    • Make sure the battery is facing out / up
    • Make sure the battery tab is not interfering with the battery contacts
    • Make sure the top part of the battery tab is on top of the battery
  5. Re-insert the battery rubber seal + 6. Slide the battery cover back into the original position
  6. Responsibly dispose of spent batteries.

Operation

  • Press Power to switch the gauge ON or Off. Caliper will auto shut off within 5 minutes of non-use.
  • Press mm/in to switch the display reading between measuring units: inch, mm
  • Press the Origin key to reset origin zero. Origin zero is the absolute zero position for the calliper. Close the measure jaws and press the key to set the origin zero.
  • Press the 0/ABS key to switch between absolute/incremental reading.
  • Press the key to enter Incremental mode, and “INC” will show on the display. This gives the user the ability to set an incremental zero.
  • Press the key again to exit the mode. Normal reading/measuring will resume. “INC” will disappear from the display.
    Battery: 3V CR3023 (1 Piece)

Precautions

  • Do not expose the instruments to direct sunlight or cold temperatures.
  • Do not attempt to disassemble the calliper for an extended period.
  • Avoid exposure to electromagnetic fields.
  • Keep dry when not in use.