SALUS RX10RF Wireless Receiver Unit
SALUS Controls plc
SALUS House
Dodworth Business Park South,
Whinby Road,
Dodworth, Barnsley S75 3SP, UK.
SALES: T: +44 (0) 1226 323961
E: sales@salus-tech.com
TECHNICAL: T: +44 (0) 1226 323961
E: tech@salus-tech.com
www.salus-controls.com
SALUS Controls is a member of the Computime Group
Maintaining a policy of continuous product development SALUS
Controls plc reserve the right to change specification, design and materials
of products listed in this brochure without prior notice.
For PDF Installation guide please go to www.salus-controls.com
BOX CONTENTS, COMPLIANCE & SAFETY INFORMATION
-
1 x Installer / User manual
-
2 x Screws & 2 x Wall Plugs
-
Boiler Receiver x 1
For PDF Installation guide please go to www.salus-controls.com
INTRODUCTION
Thank you for purchasing the SALUS RX10RF system receiver. This unit is
designed to work with iT600 range of Zigbee network products.
The RX10RF can be configured as remote boiler switch or a simple single
channel output to control, a thermal actuator or zone valve. Please note the
two configuratons above can be used together in the one system.
These instructions are applicable to the SALUS model stated on the front cover
of this manual only.
Product Compliance
This product is CE compliant and meets the following EC Directives 2014/30/EU;
2014/35/EU; 2014/53/EU and 2011/65/EU.
Warning
This product must be fitted by a competent person, and installation must
comply with the guidance, standards and regulations applicable to the city,
country or state where the product is installed. Failure to comply with the
requirements of the relevant guidance, standards and regulations could lead to
injury, death or prosecution.
Sources of danger
The RX10RF must be disconnected from mains supply before removing the cover.
Emergency
Switch off the voltage to the individual thermostat wring centre or complete
system.
Warning
Always isolate the AC Mains supply before installing or working on any
components that require 230 VAC 50Hz supply.
SYSTEM OVERVIEW
iT600 System
User Interface
-
AUTO – System receiver output will switch on and off in relation to the command from the iT600 transmitter. The bottom slide switch in active
-
RED led only in AUTO means that there is no output from the receiver.
-
RED and Green LED only in AUTO means that there is an output from the receiver. The device that the receiver is connected to will be switched on.
-
Manual- system receiver output is controlled by the bottom slide switch. Either permenetly ON or OFF. The LED status in manual is the same as AUTO.
RX1 & RX2 RECEIVER CONFIGURATION
The receiver can be configured as a Boiler Receiver (RX1) where it will react to signals from a large number of components such as SALUS wireless wiring centres, wireless thermostats used with SALUS wireless radiator valves as well as another receiver configured as a Stand Alone receiver (RX2).
SYSTEM OVERVIEW – IT600 SYSTEM CONFIGURED AS RX1
The unit can be switched internally switched to be used on two channels, RX1
(boiler receiver) or RX2 (single room receiver). Ensure the unit is not
powered during setting of the RX1/RX2 slide switch.
The unit is supplied with the switch in the RX1 position (Boiler Receiver). In
this mode, the unit can be wired to the boiler to switch it on or off using
the wireless signals it receives other SALUS products on the SALUS Zigbee
network
System Receiver configured to boiler receiver RX1. Refer to reverse side for wiring.
SYSTEM OVERVIEW – IT600 SYSTEM CONFIGURED AS RX2
With the unit switched to RX2, the unit will act as a single room receiver.
Switching of the unit will be controlled by a paired SALUS VS10/20RF
Thermostat. Depending on its intended use, the unit can be used to switch a
motorised valve, thermal actuator or pump.
As well as being used in this way, the RX2 can be used in conjunction with
another unit set up as an RX1 (Boiler receiver). When there is a call for heat
from the thermostat paired to the RX2 both of the wireless receivers will
operate turning on both the boiler and the motorised valve / pump.
NB: Only 1 RX1 and 1 RX2 can be used as part of a network.
System receiver configured as stand alone receiver RX2. Refer to reverse side for wiring.
INSTALLATION
Electrical Connection
Terminal | Function |
---|---|
COM | Common Contact (volt free input) |
NO | Normally Open Contact (volt free output) |
L | Incoming Mains – Live |
N | Incoming Mains – Neutral |
The RX10RF Receiver should be mounted in a suitable location that is both
accessible for the connection of mains and control wiring, and allows good
reception of the RF signal. The Receiver needs a 230V AC mains supply to
operate, and this should be fused appropriately (16A max.).
The Receiver should be mounted in a location where it will not come into
contact with water, moisture or condensation. There are few electrical
connections required to the RX10RF, and these connections should be made to
the terminal block inside the Receiver. No Earth connection is required for
the correct and safe operation of the RX10RF, but a parking terminal is
provided to connect an Earth wire if one is present.
-
Loosen the screws at the bottom of the receiver unit.
-
Unclip the front of the unit.
-
Fit the back of the receiver unit to the wall using the fittings supplied.
-
Wire up the receiver using one of the schematics*.
-
Clip the front of the unit back on by aligning the fittings and pushing into place.
-
Securely screw the front of the receiver in place.
Schematics
*Configured as RX1
*Configured as RX2
Reset Button
If for any reason the system receiver stops operating, press reset and check
system operation.
Replacing the System Receiver
If for any reason the system receiver needs to be removed/replaced, press the
delete from network.
Power Up
-
Ensure Coordinator is powered up and ready for pairing.
-
Power up the receiver. The red light will flash.
-
When the receiver has successfully joined the Zigbee network, the red LED will go steady.
-
Please refer to VS10/VS20RF manual for system pairing.
-
Once your system setup is complete, remember to take the coordinator out of pairing mode.
TECHNICAL DETAIL
Model | RX10RF |
---|---|
Type | Wired system receiver designed for 230VAC heating applications |
Control | ON-OFF control |
Environment Ratings | |
Operating Temperature | 0 ºC to +50 ºC |
Storage Temperature | -20 ºC to +60 ºC |
Operating Humidity | 5-95 %RH |
Switch Voltage | 0-230VAC 16AMP |
Power Source | 230Vac 50Hz |
User Interface | Slide switch, Bi Colour LED, RED/GREEN |
Operating Temperature | 0 to 50 ºC |
Storage Temperature | -20ºC to 60ºC |
Frequency | 2.4 GHz |
Approval | CE |
WARRANTY
SALUS Controls warrants that this product will be free from any defect in
materials or workmanship, and shall perform in accordance with its
specification, for a period of five years from the date of installation. SALUS
Controls sole liability for breach of this warranty will be (at its option) to
repair or replace the defective product.
Customer Name: …………………………………………………………………………………………….
Customer Address: ………………………………………………………………………………………….
………………………………………………………. Post Code: ……………………………………………
Tel No: ……………………………………………. Email: ………………………………………………….
Engineers Company: ……………………………………………………………………………………….
Tel No: ……………………………………………. Email: ………………………………………………….
Instalation Date: …………………………………………………………………………………………….
Engineers Name: ……………………………………………………………………………………………
Engineers Signature: ………………………………………………………………………………………