R V R Elettronica VJ5000TE V1 Tube Amplifiers Family Owner’s Manual

June 13, 2024
R V R ELETTRONICA

R V R Elettronica VJ5000TE V1 Tube Amplifiers Family Owner’s Manual

VJ5000TE/V1
VJ5000TE/V2

Features

  • Tuning motorized for input, plate and load able to cover the entire band from 87,5 to 108 MHz.
  • High impedance for the low-pass filter.
  • High overall efficiency.
  • Built-in remote control.
  • Measuring extremely accurate for the forward and reflected power.
  • Electronic start timing with Time Saving.
  • Power amplifier on extractable undercarriage, in order to facilitate the transportation and maintenance.
  • Meets or exceeds all FCC and CCIR requirements.
  • Protections against excessive VSWR, grid current, temperature, safety interlocks, inadequate ventilation and unbalanced AC line.
  • No neutralization required.
  • Visualization of the interventions number.

Characteristics

  • Motorized tuning for input, frequency tuning and power output coupling (Tune & Load), capable of covering the entire band from 87.5 to 108 MHz.
  • High efficiency low pass filter.
  • High overall efficiency.
  • Integrates the possibility of remote control.
  • Extremely accurate direct and reflected power measurement.
  • Time-saving electronic start adjustment.

R.F. Power Amplifiers 87,5 – 108 MHz

  • Removable power supply on trolley, to facilitate transport and maintenance.

  • Meets or exceeds all FCC and CCIR requirements.

  • Protection circuits for VSWR, grid current, plate current, temperature, safety lockout systems, airflow failure and unbalanced AC line. Filament control in both current and voltage.

  • No neutralization is required.

  • Display of the number of interventions.

  • Advanced recycling overload and protection system that provides automatic re-start after approximately 30 seconds of stand-by in case of failure. This procedure is repeated 9 times and, in the case of a persistent fault, the block becomes permanent until a manual or remote re-start command is applied.
    If, however, during one of the re-starts the fault disappears, the counting system is reset after a regular working period of 30 minutes.

  • Foldback system on all protection actions so as to never completely interrupt the power amp, but to keep the broadcast on so as not to damage the amplifier.

Technical specifications

All pictures are RVR’s property and they are only indicative and not binding. The pictures can be modified without notice. These are general specifications. They show typical values and are subject to change without notice.

Ordering information

RVR Elettronica SpA Via del Fonditore, 2/2c

Roveri Industrial Area  40138 Bologna  Italy Phone: +39 051 6010506  Fax: +39 051 6011104
e-mail: info@rvr.it  web: http://www.rvr.it

Read More About This Manual & Download PDF:

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>