SATCO 8T8-LED-24-8XX-DR 4000K LED Light Bulb Instruction Manual

June 4, 2024
SATCO

SATCO 8T8-LED-24-8XX-DR 4000K LED Light Bulb

Product Features

  • UL certified
  • Pug-n-Play replacement
  • Full glass housing: No Aging, Yellowing
  • Bending
  • Compatible with Instant Start
  • Program Start
  • Rapid Start T8 electronic ballast and Emergency ballast.

Product Applications

Widely used in residential buildings, offices, shopping malls, supermarkets, hospitals, assembly lines, warehouses, etc. for energy saving illumination.

Please completely comply with these instructions and notes, to ensure that the product is operated in a safe condition.

Safety Precautions

WARNING
Risk of shock
Disconnect power before installation. LED T8 lamp for use only with products described and installed in accordance with product specifications. LED T8 lamp to be operated with fluorescent electronic ballast and Emergency ballast

RISK OF FIRE
USE ONLY IN PLACE OF FLUORESCENT LAMPS SPECIFIED ON LABEL.

RISK OF ELECTRIC SHOCK
SUITABLE FOR DAMP LOCATIONS.

INSTALLATION INSTRUCTIONS

Turn Power OFF
  • Remove lens or diffuser if applicable
  • Remove existing fluorescent lamps from the luminaire.

SATCO 8T8-LED-24-8XX-DR 4000K LED Light Bulb 2

Bring LED lamp to luminaire and insert lamp pins into Luminaire lamp holders.

Rotate LED lamp

Until lamp locks in place. Ensure that the LED lamp front points away from the back of the luminaire.

Note
Install LED T8 replacement lamp one for each fluorescent lamp removed.

  • Place lens or difuser back in place (if applicable)
  • Switch nower ON

Instant Start Ballast Wiring Diagram(Correct)

Two Lamps Ballast Correct Wiring

SATCO 8T8-LED-24-8XX-DR 4000K LED Light Bulb 6

Three Lamps Ballast Correct Wiring

SATCO 8T8-LED-24-8XX-DR 4000K LED Light Bulb 7

Four Lamps Ballast Correct Wiring

SATCO 8T8-LED-24-8XX-DR 4000K LED Light Bulb 8

Instant Start Ballast Wiring Diagram(Incorrect)

Two Lamps Ballast Incorrect Wiring

SATCO 8T8-LED-24-8XX-DR 4000K LED Light Bulb 9

Three Lamps Ballast Incorrect Wiring

SATCO 8T8-LED-24-8XX-DR 4000K LED Light Bulb 10

Four Lamps Ballast Incorrect Wiring

SATCO 8T8-LED-24-8XX-DR 4000K LED Light Bulb 11

DO NOT INSTALL THIS LAMP IN A PRE HEAT LUMINAIRE

THIS LAMP ONLY OPERATES ON ELECTRONIC BALLASTS. IF LAMP DOES NOT LIGHT WHEN THE LUMINAIRE IS ENERGIZED, REMOVE LAMP FROM LUMINAIRE AND CONTACT LAMP MANUFACTURER OR QUALIFIED ELECTRICIAN.

CAUTION

RISK OF FIRE
IF THE LAMP OR LUMINAIRE EXHIBITSS UNDESIRABLE OPERATION (BUZZING, FLICKERING, ETC.), IMMEDIATELY TURN OFF POWER, REMOVE LAMP FROM LUMINAIRE AND CONTACT MANUFACTURER.

Safety Information

  • Check the lamp before installation, if there is any damage caused during transportation, do not install.
  • Maintenance should be carried Out by technical personnel only.
  • Do not stare at the light source with bare eyes for a long time, or beam to others eyes.
  • Do not place any objects on the lamp.
  • Keep the lamp away from flame or high temperature objects.
  • Only replace with same type of LED tube.

Risk of electrical shock
If the glass lamp tube is broken, the lamp must be disposed of immediately

Maintenance Notes

  • Disconnect lamp from power supply before any maintenance.
  • Clean luminaire with dry cloth.
  • Do not clean the lamp with corrosive chemicals.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions

  • This device may not cause harmful interference.
  • This device must accept any interference received, including interference that may cause undesired operation.