SellEton SL-60KX Heavy Duty 7′ Truck Axle Scale Installation Guide

June 3, 2024
selLEton

Scoles.com
Installation Instruction for Axle Scales

SL-60KX Heavy Duty 7′ Truck Axle Scale

SellEton SL 60KX Heavy Duty 7 Truck Axle Scale-

SellEton SL 60KX Heavy Duty 7 Truck Axle Scale-fig1

Scale Components

SellEton SL 60KX Heavy Duty 7 Truck Axle Scale-fig2

Bolts details

| bolt for load cell M24 x 75 mm (total: 16 pcs)
---|---
| expansion bolt M16 x 100 mm (total: 28 pcs)
| Limit bolt M20 x 70 mm (total: 8 pcs)
| bolt for bending plate (total: 16 pcs)
| M16 eyebolt (total: 2 pcs)

Tools Required for Installation

SellEton SL 60KX Heavy Duty 7 Truck Axle Scale-fig3

  1. Make sure the complete installation is done on a level ground .
    SellEton SL 60KX Heavy Duty 7 Truck Axle Scale-fig4

  2. Bolt the installation plate to the ramps and place the ramps 87″ apart in parallel with forklift .

  3. Bolt the installation plates to the platform and screw the four threaded level feet into the four corners of the platform while lifting it with the forklift .

  4. Place the platform between the two ramps, making sure all the feet sit inside the rings on the ramps .
    If necessary, adjust the height with a screwdriver from the top.

  5. Pull out the interface cable Open the cover on the side and you will find the junction box with a 50ft long cable nested inside. Run the cable (with connector) through hole on the bottom and pull it out from underneath as long as you need . Close the cover with the original screws after this is finished .

  6. Follow the same steps to install the other set .

  7. Plug the connectors on the interface cables to the 2 ports of the indicator .
    SellEton SL 60KX Heavy Duty 7 Truck Axle Scale-fig9

  8. For permanent use, install anchoring bolts to the ramps .