SellEton SL-7510-SS Stainless Steel Indicator Instruction Manual

June 1, 2024
selLEton

SellEton SL-7510-SS Stainless Steel Indicator

SellEton-SL-7510-SS-Stainless-Steel-Indicator-product

Product Information

Specifications

  • Platform: 2 pieces
  • Ramp A: 4 pieces
  • Load Cell: 8 pieces
  • Feet: 8 pieces
  • Indicator: 1 piece
  • Junction Box: 2 pieces
  • Signal Cable for Indicator: 2 pieces
  • Bending Plate: 2 pieces
  • Bolt for Load Cell M24 x 75 mm: 16 pieces
  • Expansion Bolt M16 x 100 mm: 28 pieces
  • Limit Bolt M20 x 70 mm: 8 pieces
  • Bolt for Bending Plate: 16 pieces
  • M16 Eyebolt: 2 pieces

Product Usage Instructions

Tools Required for Installation

  • Forklift
  • Tape
  • Churn drill
  • Wrench
  • Flat screwdriver
  • Hammer

Installation Steps

  1. Make sure the complete installation is done on a level ground.
  2. Bolt the installation plate to the ramps and place the ramps 87 inches apart in parallel with the forklift.
  3. Bolt the installation plates to the platform and screw the four threaded level feet into the corners of the platform while lifting it with the forklift.
  4. Place the platform between the two ramps, ensuring all feet sit inside the rings on the ramps. Adjust height if necessary with a screwdriver.
  5. Pull out the interface cable from the junction box and run it through the hole on the bottom. Connect it to the indicator.
  6. Repeat steps for the other set.
  7. Plug the connectors on the interface cables to the ports of the indicator.
  8. For permanent use, install anchoring bolts to the ramps.

FAQ

Q: What should I do if the indicator is not displaying accurate readings?

A: Check the connections between the load cells and the indicator. Ensure they are securely plugged in and not damaged. Recalibrate the system if needed.

Q: Can I use this product outdoors?

A: The product is designed for indoor use. Exposure to outdoor elements may affect its performance and longevity.

Q: How often should I check and calibrate the scale?

A: It is recommended to perform regular checks for accuracy and calibration at least once a month or as per your usage frequency to maintain precise measurements.

PRODUCT OVERVIEW

SellEton-SL-7510-SS-Stainless-Steel-Indicator-fig-1

WHAT IS IN THE BOX

SellEton-SL-7510-SS-Stainless-Steel-Indicator-fig-2

Scale Components

SellEton-SL-7510-SS-Stainless-Steel-Indicator-fig-3

Bolts details

SellEton-SL-7510-SS-Stainless-Steel-Indicator-fig-4

Tools Required for Installation

SellEton-SL-7510-SS-Stainless-Steel-Indicator-fig-5

  1. Make sure the complete installation is done on a level ground.
  2. Bolt the installation plate to the ramps and place the ramps 87″ apart in parallel with forklift .
  3. Bolt the installation plates to the platform and screw the four threaded level feet into the four corners of the platform while lifting it with the forklift .
  4. Place the platform between the two ramps, making sure all the feet sit inside the rings on the ramps .
    If necessary, adjust the height with a screwdriver from the top.

SellEton-SL-7510-SS-Stainless-Steel-Indicator-fig-6

  1. Pull out the interface cable Open the cover on the side and you will find the junction box with a 50ft long cable nested inside. Run the cable (with connector) through hole on the bottom and pull it out from underneath as long as you need .
    Close the cover with the original screws after this is finished .

  2. Follow the same steps to install the other set .

  3. Plug the connectors on the interface cables to the 2 ports of the indicator .

  4. For permanent use, install anchoring bolts to the ramps .

SellEton-SL-7510-SS-Stainless-Steel-Indicator-fig-7

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals