SellEton SL-910X Remote Display User Manual
- June 1, 2024
- selLEton
Table of Contents
Scales.com
User Manual SL-910X Remote
Display
USER’S MANUAL
NOV 2023
www.selletonscales.com
FEATURES
- Connects to your indicator to display live weight on a larger screen
- Bright LED display is readable in high and low light
- Display turns green when weight is stable and red when unstable
- 6 digit display
- Painted metal construction
- For indoor or outdoor use
- Includes two mounting brackets
- Connects to most indicators
- Ideal for use with vehicle scales, so drivers can see the weight from inside their vehicle, and proceed once the weight is green/stable
- Easy to install, connects with RS232 port
MOUNTING DIMENSIONS
CONNECTOR
SET-UP EXAMPLE
Here is an example of how to pair your scoreboard to SellEton’s most popular indicators. To set up SL-910X remote display, parameter settings need to be changed on your SL-7510 or SL-7516 indicator to allow communication between the two devices.
SL-7510 PARAMETER SETTINGS
To enter parameter settings, follow the procedure below:
- Press and hold the HOLD and PRINT key at the same time for 2 seconds
- Use the arrow keys to change C01 to C18
- Press the PRINT key to enter/edit the parameter setting
- Use the arrow keys to change the settings of the below parameters
- Press the ACCUM key to save and exit parameter settings
SL-7516 PARAMETER SETTINGS
To enter calibration/parameter settings, follow the procedure below:
- Press and hold the ON/OFF and SET key at the same time for 2 seconds
- Use the arrow keys to change C01 to C18
- Press the SET key to enter/edit the parameter setting
- Use the arrow keys to change the settings of the below parameters
- Press the ON/OFF key to save and exit parameter settings
Function | Parameter | Settings/Options |
---|---|---|
Communication Setting | C18 | Set the serial interface data output method: |
0 = Turn off serial interface data output
1 = Continuous sending mode, for remote display
2 = Print mode, for ticket printer
3 = Command request mode, connect computer.
4 = PC continuous sending mode, connect computer
Baud Rate| C19| 0=1200
1=2400
2=4800
3=9600 (SL-910X remote display)
For more help, contact us at:
844-735-5386
Remote Display Continuous Sending Mode
Note: Baud Rate must be set to 9600
State A
Bits0,1,2
0| 1| 2| Decimal point position
1| 0| 0| XXXXXX0
0| 1| 0| XXXXXXX
1| 1| 0| XXXXX.X
0| 0| 1| XXXX.XX
1| 0| 1| XXX.XXX
Bits3,4
| Division
0| 1| X1
1| 0| X2
State B
BitsS| function
Bits0| gross=0, net=1
Bits1| Symbol: positive=0, negative=1
Bits2| Overload (or under zero)=1
Bits3| dynamic=1
Bits4| unit: lb=0, kg=1
Bits5| Constant 1
Bits6| Constant 0
State C
Bit2| Bit1| Bit0| unit
0| 0| 0| Kg or lb
0| 0| 1| g
0| 1| 0| t
Bit 3| printing=1
Bit 4| Extend display=1
Bit 5| Constant 1
Bit 6| Constant 0