sellEton Scales com SL-7517 Weighing Indicator User Manual

June 1, 2024
sellEton Scales com

sellEton Scales com SL-7517 Weighing Indicator

sellEton-Scales-com-SL-7517-Weighing-Indicator-PRODUCT

Product Specifications

  • Model: SL-7517
  • Type: Weighing Indicator
  • Main Function: Basic weighing functions, Peak hold, Hold function, Auto hold, Animal function, Battery capacity indication, RS232 function
  • Power: Battery operated (with battery capacity indication) or optional power adapter
  • Interface: User-friendly display
  • Additional Features: Power efficiency, Cost-effectiveness, Optional real-time clock for RS232 function

Product Usage Instructions

Installation

  • Installation: Install the SL-7517 weighing indicator within the body of the floor scale as per the provided installation picture.
  • Electrical Connection: Connect the indicator to power using either batteries or an optional power adapter. Ensure proper electrical connection for accurate functionality.

Operation

Ensure the indicator is securely installed within the floor scale body. Use the user-friendly interface to perform basic weighing functions like Zero, Tare, Total Peak hold, Hold function, and Animal function.

Calibration & Parameter Setting

  • Enter Calibration: Follow the calibration instructions provided in the manual to calibrate the indicator for accurate weighing.
  • Key’s Function: Familiarize yourself with the key functions for the efficient operation of the indicator.

Maintenance

  • Regular Error   and Maintain Method: Refer to the manual for troubleshooting common errors and maintaining the indicator.
  • Daily Maintenance: Perform daily maintenance tasks to ensure optimal performance of the indicator.
  • Battery Maintenance: If using batteries, follow the maintenance instructions for battery longevity.
  • Restore Default Parameters: In case of any issues, restore default parameters as instructed in the manual.

Frequently Asked Questions

Q: How do I calibrate the SL-7517 weighing indicator?

A: To calibrate the indicator, follow the calibration instructions provided in section 4 of the user manual.

Q: Can I use a power adapter instead of batteries to operate the SL-7517?

A: Yes, you can use an optional power adapter to operate the SL-7517 weighing indicator.

Q: What is the main function of the SL-7517 indicator?

A: The main functions include basic weighing operations, peak hold, hold function, animal function, battery capacity indication, and optional RS232 function with a real-time clock.

SAFETY INSTRUCTIONS

  • WARNING Set, calibrating, inspecting, and fixing the weighing indicator is prohibited by non-professional staff.
  • Please make sure the weighing display is well-earthing.
  • The indicator is an electrostatic-sensitive device.
  • Please power off during electrical connections, internal components touched by hand are prohibited, and please take the anti-static measure.

SUMMARY

  • The SL-7517 is a slim plastic indicator, custom-designed by our company for floor scale applications. This indicator can be installed within the body of the floor scale, making it convenient for transportation and packaging.
  • The interface of the indicator display is user-friendly, offering straightforward operation, stable performance, power efficiency, and cost-effectiveness.
  • Main Function
    • Basic weighing function: Zero /Tare /Total
    • Peak hold/Hold function/Auto hold/ Animal function
    • Battery capacity indication
    • Automatically power OFF
    • RS232 function can be optional by a real-time clock
  • Technical Parameters
    • Stimulating voltage +3.3 VDC
    • A/D converting speed 10 times/sec
    • Load capacity It can connect 4 pcs 350Ω load cell at most
    • Resolution 5000e
    • Interval 1/2/5/10/20/50
    • Display 6-digit LED word height: 20.3mm
    • Key ON/OFF TOTAL TARE ZERO SET
    • Load Signal range: -7 12.8mV
    • Ambient temperature: -10 ~40℃
    • Optional power Built-in power supply 3.7V/2Ah Lithium battery life of 25 hours

Outline and Installation PicturesellEton-Scales-com-SL-7517-Weighing-
Indicator-FIG-13

INSTALLATION & CALIBRATION

Installation

  • Please open and inspect the accessories listed in the included packing list as per the instructions.
  • If any parts are missing or damaged, kindly contact the company’s after-sales service department promptly to ensure the proper use of the indicator.
  • The indicator can be positioned directly on a desktop surface.

Electrical Connection:

  • Power Supply: The indicator is powered by a 5V/1A adapter.
  • To power it, simply plug the adapter directly into the “DC” pin on the back cover of the indicator.
  • This will provide the necessary power supply for the indicator to function properly.

Connection indicator with loadcell:

It can connect 4 pcs 350Ω Load cells at most with an M16-5 connector. As shown below

Power connection:

The indicator is powered by a 5V/1A adaptor, If you plug the adapter directly into the “DC” pin at the back cover the indicator is ok.

Communication interface:

Serial port RS232 uses the DB9 to connect to a big display, printer, or computer. As shown below:

Pin Definition Instructions
2 TXD Transmit data
3 RDX Received data
5 GND Ground

BASIC OPERATION

Key and displaysellEton-Scales-com-SL-7517-Weighing-Indicator-
FIG-3

Weighing Indicator Key’s FunctionsellEton-Scales-com-SL-7517-Weighing-
Indicator-FIG-4 sellEton-Scales-com-SL-7517
-Weighing-Indicator-FIG-5

Weighing indicator display instructionssellEton-Scales-com-SL-7517
-Weighing-Indicator-FIG-6

Operation:

  • Press for 3 seconds to power on or power off.
  • Kg/Lb Conversion: If you choose kg/lb conversion, in normal weighing mode, you can press a key to achieve kg/lb conversion.
  • TARE/ZERO: When weighing exceeds the zero range( ±2%) and is stable, press to enter into net weighing mode, display net weight zero, Tare and Net light on,
  • Gross light off.
  • When weighing in the zero range ( ±2%)and stable, press back to gross weighing mode, display gross weight zero, Gross light on, Tare, and Net light off.
  • Preset tare.
  • Press “Tare” for 2 seconds and enter the Tare weight to the Tare function.

Hold Functions

  • This indicator includes peak hold, hold, auto-hold, animal function, and trails of animal function.
  • C11=0 no hold function
  • C11=1 Peak hold C11=2 Data hold
  • C11=3 Auto-hold
  • C11=4 Animal function
  • C11=5 Trails of animal function
  • C11=6 Stable hold function
  • Peak-hold: Press the HOLD key, then the Hold light is on, and show the maximum data on the weighing indicator. Press the HOLD key again to exit the hold function
  • Hold: Press the HOLD weighing indicator. Press the HOLD key, then the Hold light is on and show the data on the key again to exit the hold function.
  • Auto-hold: If the weight on the scale is above 20d and keeps stable, the indicator will show the data for 6 seconds and the (HOLD) light is on, after 6 seconds the indicator back to general weighing, and the HOLD light is off.
  • Animal function: Press the HOLD key, and the indicator will show “LOC” for 5 seconds, average the collected weight, and show the calculated animal weight the (light is on.
  • Press the HOLD key again to exit it. The HOLD light is off.
  • Trails of animal function: In the trails, animals are automatically weighed with the front legs placed on the scale. The duration of the animal weighing process can be configured using C40.
  • Once the animal’s weight has been determined, the indicator will briefly display “LOC” for 5 seconds.
  • During this time, the collected weights are averaged to calculate the animal’s weight. After the animal steps off the scale, the indicator returns to its standard weighing mode, and the “Hold” light turns off.
  • Stable hold function: Once the animal is on the scale, it will automatically stabilize, and the indicator will calculate the weight of the animal.
  • This automatic animal weighing function, when compared to the trial of animal function, doesn’t require any manual triggering and offers a quicker response.
  • It also can support the weighing of multiple animals on the scale simultaneously.
  • However, it is important to note that this function may not be suitable for very active animals.
  • To use this function effectively, it is necessary to configure the parameters C28 and C29 for digital filtering.

TOTAL

  • Accumulation operation: At Zero mode, load weight till stable, press the TOTAL key to go to accumulating mode, TOTAL light on, display “n001”, and then display loaded weight; unload weight, back to zero, load weight again till stable, press
    then show the loaded weight. Repeat it a maximum of 999 times. TOTAL display “nO02”,

  • Check the total weight operation: Press PRINT hold it then press TOTAL at the same time, display “n (accumulating times) then display total weight. If the total weight does not exceed 6 digits, it is displayed as 6 data total, otherwise, the total weight is 8 data total, and it shows the first 4 digits, then the last 4 digits. For example, the first 4 digits are 0012 the last 4 digits are “34.56”, which means the actual weight is “1234.56

  • Exit accumulate function: At TOTAL (accumulate) mode, press a TOTAL key the indicator shows cir n which means don’t clear the total weight, press the key to confirm it and exit;

  • If clear the total weight is when displaying “cir n”, press TARE ZERO to change it to “cir y” It means a clear total weight display. Press mode. PRINT to clear the total weight and exit accumulating

Ten times higher resolutions

Press the PRINT and TARE ZERO keys at the same time, and you will get 10 times higher resolutions. And it will back to normal weighing after 3 seconds

Up and Under limit alarm

Please. set C13= Up limit, C14=Under limit, when the weight is over the up limit, the “Hi” light will on, and the indicator will make a sound to alarm
When the weightis below than the low limit, the “Lo” light will be on. When the weight is within the limit, the “OK” light is on

Print

When the data is stable, the connection to the printer will be printed after pressing PRINT 1 second.

Calibration and Parameter Settings

Enter setting

  • There are two methods to enter the settings menu.
  • When the switch “CAL” is off, press PRINT then press **** at the same time, hold it, and you will enter the C08-C39 setting.

Key Functions

Steps of calibration operation:

Before going to the next step, kindly press PRINT

Step Display Remarks
1. [C01   ] After you enter calibration mode, it displays [C01    ]. Press

Print.
2.| [C1    1] [C1   2]| Weight unit option:1=kg option:2=lb
3.| [C02    ] [C02   1] [C02   2] [C02   3] [C02   4]| Set decimal digits option:0/1/2/3/4 Select decimal digit example: two decimal points:[C02 2]
4.| [C03    ] [C03   1] [C03   5] [C03   10] [CO3  20] [CO3  50]| Division setting option:1/2/5/10/20/50 Select required disvion example:division 5:[C03 5]
5.| [C04    ] [0100.00]

[0100.00]| Max capacity example: max weighing 100kg: [0100.00]
6.| [C05    ] [C05   0] [C05   1] [CAL 10]~ [CAL  0] 。。。。。。 [0000.00]| Zero calibration option:0=non-calibration zero 1=need calibration zero calibration zero please choose 1 and ensure the scale is empty and the “stable” light is on Ensure zero calibration and countdown. Till show[0.00](example for two decimal points)。

sellEton-Scales-com-SL-7517-Weighing-Indicator-FIG-14

NOTE: After completing the configuration of the parameters mentioned above, it is advisable not to frequently reset the default parameters. Doing so can help avoid the loss of the original parameter settings.

Application parameters setting chart

Functions Setting Items parameters setting and instruction
Warning tone C08 warning tone Options: 0 = close warning tone 1 = open

warning tone
Automatic power off| C09 Automatic power off| Option:0=close auto power off 10= keep still within 10 min. power off automatically 30= keep still within 30 min. power off automatically 60= keep still within 60 min. power off automatically
Power saving setting| C10 Power saving setting power off| Option:0= close power saving setting 1= Close the backlight after 3 minutes 2= Close the backlight after 5 minutes
Hold function| C11 Hold mode| Option:0=close hold function

1=Peak hold /2=Data Hold /3=Auto-hold /4=Animal weighing

/5=Trails of animal function

Hold: it shows the current weight value. Mainly application for animal weighing.

Hold time| C12 value| Hold time (if you choose C11=4, you can set the time) Enter a sampling time of 0-9 seconds
---|---|---
Upper/lower limit alarm| C13 Upper limit alarm value| At setting function mode, after directly entering C15, the indicator will show the inner code
C14 Lower limit alarm value value
Inner Code display| C15 Check the inner code value| At setting function mode, after directly entering C15, the indicator will show the inner code
Date and time| C16 Date value| At setting function mode, after directly entering C15, the indicator will show the inner code
C17 Time value| At setting function mode, after directly entering C15, the indicator will show the inner code

Communication Setting

sellEton-Scales-com-SL-7517-Weighing-Indicator-FIG-15

Application settingsellEton-Scales-com-SL-7517-Weighing-Indicator-
FIG-16sellEton-Scales-com-SL-7517-Weighing-
Indicator-FIG-17sellEton-Scales-com-SL-7517
-Weighing-Indicator-FIG-18

Exit setting

For example [C10 1], press, confirm it and then press to exit and save it.

OUTPUT DATA FORMAT

Computer continuous sending formatsellEton-Scales-com-SL-7517-Weighing-
Indicator-FIG-10

  • S1: weight status, ST= standstill, US= not standstill, OL= overload
  • S2: weight mode, GS=gross mode, NT=net mode
  • S3: weight of positive and negative, “+” or ” –“
  • S4: measurement unit, “kg” or “lb”
  • Data: weight value, including decimal point
  • CR: carriage return
  • LF: line feed

Serial interface reception command

RS232COM serial interface can receive simple ASCII commands.

Command word and role as follows:

Command Name Role
T Tare command Save the weight
Z Zero command Zero the weight
P Print command Print the weight
R Read   gross/net weight Read gross/net weight

Print output format

  • Net 10.00kg
  • Tare 18.88kg
  • Gross 28.88kg

Computer continuous sending format

Output continuous format

STX| SWA| SWB| SWC| X| X| X| X| X| X| X| X| X| X| X| X| C R| C K S
1| 2| 3| 4| 5| 6
State  A

Bits0,1,2
0| 1| 2| Decimal point position
1| 0| 0| XXXXXX0
0| 1| 0| X
1| 1| 0| XXXXX.X
0| 0| 1| XXXX.XX
1| 0| 1| XXX.XXX
Bits3,4| Division
0| 1| X1
1| 0| X2
1| 1| X5
State  B

Bits S| function
Bits 0| gross=0, net=1
Bits 1| symbol:positive=0,negative=1
Bits 2| overload(or lower zero)=1
Bits 3| dynamic=1
Bits 4| unit:lb=0,kg=1
Bits 5| Constant 1
Bits 6| Constant0

Maintenance

Regular Error and maintain method:sellEton-Scales-com-SL-7517-Weighing-
Indicator-FIG-11 sellEton-Scales-com-
SL-7517-Weighing-Indicator-FIG-12

Daily maintenance

To ensure a clear display on the indicator and extend its lifespan, please observe the following guidelines.

  1. Avoid placing the indicator directly in sunlight.
  2. Ensure a proper connection between the load cell and the indicator. The system should have a robust ground and be kept away from strong electric or magnetic fields.
  3. Refrain from using the indicator outdoors in rainy conditions, and it is recommended to keep it powered off in such situations.

Battery

  • In the lower right corner of the indicator, there’s a visible battery voltage display.
  • If the battery voltage becomes too low, the last grid will begin to blink, indicating that it’s time to recharge.
  • During the charging process, the battery grid will flicker, and typically, it takes around 6-8 hours to fully charge.
  • Once the battery is fully charged, all the power grid lights will illuminate.
  • It’s worth noting that the indicator features a built-in intelligent charge management chip, which allows it to continue using the power supply after reaching a full charge, preventing overcharging of the battery.

Restore default parameters

  • Enter the setting menu, set C07= 1, press PRINT then press exit saving setting, all parameters will be back to the default setting
  • Note: Please avoid restoring default parameters if you lack professional knowledge and do not have experience with scale calibration.

Default parameter form

Parameter Instruction Default value
C01 Calibration unit 1
C02 decimal digits 0
C03 Division value 2
C04 Max capacity 10000
C05 Empty scales 0
--- --- ---
C06 Capacity calibration 0
C07 restore the default parameters 0
C08 Warning tone 1
C09 Automatic power off 0
C10 Power saving mode 3
C11 Hold function 2
C12 Animal weighing mode 5
C13 Upper limit warning 000000
C14 Lower limit warning 000000
C15 Inner code display
C16 Date
C17 Time
C18 Serial    interface    data   output method 0
C19 Serial interface Baud rate 3=9600
C20 Manual zero setting 2
C21 Initial zero setting 10
C22 Automatic zero tracking range 0.5
C23 Automatic zero tracking time 1
C24 Overload range 9
C25 Negative display range 10
C26 Standstill time 1
C27 Standstill range 2
--- --- ---
C28 Dynamic filter 1
C29 Noisy filter 2
C30 Date format 0 (1*)
C31 kg/lb conversion 0 (1*)
C35 Print format 1
C36 Local gravitational acceleration 9.7936
C37 Destination gravitational acceleration 9.7936
C38 Version number view
C39 Multi-interval application 0
C40 Animal scale delay

NOTE: means this option is only for NTEP version

Documents / Resources

| sellEton Scales com SL-7517 Weighing Indicator [pdf] User Manual
SL-7517, SL-7517 Weighing Indicator, Weighing Indicator, Indicator
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

sellEton Scales com User Manuals

Related Manuals