PeakTech 2800 A Laser-Distance Meter Instruction Manual
- June 3, 2024
- PeakTech
Table of Contents
- Safety Precautions
- Features
- Technical Data
- Front Panel Description
- Keypad
- Initial Operation and Setting
- Switching on and off
- Clear Key
- Setting the reference level
- Display Illumination
- Distance Unit Setting for Instrument
- Single Distance Measurement
- Continous Measurement & Max / Min Measurement
- Addition/Subtraction of Areas
- Addition/Subtraction of Areas
- Area Measurement
- Volume Measurement
- Pythagorean measurement
- Indirect Measurement – length (x) using 3 Measurements
- Readings memory
- Stacking Out – Preset distance
- Delayed Measurement
- Measuring Conditions
- Troubleshooting
- Battery Replacement
- Customer Support
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
PeakTech 2800 A Laser-Distance Meter
Safety Precautions
This product complies with the requirements of the following European
Community Directives: 2004/108/EC (Electromagnetic atibility) amended by
2004/22/EC (CE-Marking). Pollution degree 2.
To ensure safe operation of the equipment, the following safety precautions
must be observed.
Damages resulting from failure to observe these safety precautions are exempt
from any legal claims whatever.
- Handle the device with extreme caution when it is switched on (laser beam emission)
- Never point the laser beam at the eyes of humans or animals.
- Do not point the laser beam at gaseous substances or gas containers (risk of explosion).
- Keep the laser beam away from reflective objects (risk of injury to the eyes).
- Avoid contact with the laser beam (do not expose the body to laser beam emissions).
- Never let children play with laser-emitting devices unsupervised.
- Do not operate the meter before the cabinet has been closed and screwed safely as terminal can carry voltage.
- Comply with the warning labels and other info on the equipment.
- Do not subject the equipment to shocks or strong vibrations.
- Do not operate the equipment near strong magnetic fields (motors, transformers etc.).
- Keep hot soldering irons or guns away from the equipment.
- Allow the equipment to stabilize at room temperature before taking up measurement (important for exact measurements).
- Replace the battery as soon as the battery indicator “BAT” appears. With a low battery, the meter might produce false reading that can lead to electric shock and personal injury.
- Fetch out the battery when the meter will not be used for long period of time.
- Periodically wipe the cabinet with a damp cloth and mid detergent. Do not use abrasives or solvents.
- The meter is suitable for indoor use only
- Do not store the meter in a place of explosive, inflammable substances.
- Do not modify the equipment in any way
- Do not place the equipment face-down on any table or work bench to prevent damaging the controls at the front.
- Opening the equipment and service – and repair work must only be performed by qualified service personnel
- Do not use the instrument without instruction
- Avoid deliberate or irresponsible behavior on scaffolding, when using ladders, when measuring near machines which are running, or near parts of machines which are unprotected
- Avoid aiming directly into the sun
- Avoid inadequate safeguards at the surveying site
- Measuring instruments don’t belong to children hands.
Cleaning the cabinet
Clean only with a damp, soft cloth and a commercially available mild household
cleaner. Ensure that no water gets inside the equipment to prevent possible
shorts and damage to the equipment.
Laser Classification
The Laser Distance Meter produced a visible laser beam which emerges from the
front of the instrument.
Laser Class 2 products
Do not look into the laser beam and do not point the laser beam unnecessarily
at other people. The eyes are normally protected by aversion reactions,
including the blink reflex. Be sure to read the corresponding warning notices
on the device and in these operating instructions and make them accessible to
subsequent users as well.
Warning!
Looking directly into the beam with optical aids (e.g. binocular, telescopes)
can be hazardous.
Precautions: Do not look directly into the beam with optical aids.
Caution!
Looking into the beam may be hazardous to the eyes.
Precautions: Do not look into the laser beam. Make sure the laser is aimed
above or below eye level.
Features
This professional Laser Distance Meter with LCD-Display and backlight is designed for high accuracy, one person distance measurement and as estimating tool to measure remote and difficult reachable places. Shortcut keys for addition, subtraction, Pythagoras, area and volume calculation allow a fast and reliable measurement. 99 recorded readings can be stored to the internal memory by keystroke to recall these values again later. In addition, a 90° angle try square at the lower end of the measuring device can be expanded in order to ensure a precise alignment to the measuring point.
Features
- Area, volume calculation
- Indirect measurement using Pythagoras
- Addition / Subtraction
- continuous measurement
- Min / Max Distance Tracking
- Display illumination and multi-line display.
- Audible alerting signal
- Measurements in m (meters); in (inches) or ft (Foot)
Technical Data
Range:| 0.05m to 60m (P 2800A)
0.05m to 60m (P 2801)
0.05m to 80m (P 2802)
---|---
Display:| multi function display
Measuring Accuracy:| +/- 1,5mm, typically
Measuring units:| m (meter), in (inches), ft (feet)
Memory:| 99 values
Laser:| Class 2
Laser type:| 620 ~ 680 nm, < 1mW
Auto laser switch-off:| after 20 sec.
Auto instrument switch-off:| after 150 sec.
Storage Temperature:| – 20°C … 60°C
< 80% RH
Operating Temperature:| 0°C … 40°C
< 85% RH
Battery Life:| up to 8000 measurements
Operation voltage:| 2 x 1,5 V (AAA) batteries
Dimensions (WxHxD):| 54 x 118 x 27mm
Gewicht:| ca. 135g
Front Panel Description
- Lens for laser (on the top panel)
- Multi-function display
- Keypad
- Rubberized grip surface
- Water level
- 90° Try square
Display Symbols
- Laser is ON
- Reference top, middle, bottom, angle
- Maximum
- Area, Volume, and Pythagoras
- Minimum
- Continuous measurement
- Main display
- Memory number
- Distance default
- Battery status
- Auxiliary display
- Measuring Unit
Area, Volume & Pythagorean measurement
Area measurement
Volume measurement
Indirect measurement
Indirect (second) measurement
Keypad
- On / Meas – button
- Plus (+) – button
- Area / Volume – button
- Reference point / Delayed Measurement
- Off / Clear button
- Unit – button
- Minus (-) – button
- Pythagoras measurement
- Memory – button
- Backlight – button
Initial Operation and Setting
Switching on and off
turn on the instrument and laser with the “ON / MEAS” key (1),.
If you hold down the “Clear / Off” button (5) for 2 sec., The unit turns off.
The instrument automatically turns off when it is not used for 150 seconds.
Clear Key
The last action is canceled and the displayed data is erased. If you press the Clear / Off “button (5) in the” Memory ” mode, the stored value is erased.
Setting the reference level
The default setting for the reference level is the lower edge of the
instrument. Press the “Reference” button (4) to cycle through the four
reference settings.
Whenever you change the reference setting a beep sounds. After restarting the
device, the reference level automatically returns to the default setting
(lower edge).
**Top
**
**Middle
**
**Lower edge
**
**Angle piece
**
Display Illumination
Press “Backlight”-button (10) and the backlight of the display can be switched on or off, user can trigger the function when there is a darkness situation. The value is clear visible on the LCD.
Distance Unit Setting for Instrument
Press the “UNITS”-button (6) longer to change the next type of unit, m, ft, In, ft+In then continue to click the button for the next unit selection.
Single Distance Measurement
Press the “ON/MEAS”-button (1) to the activate the laser.
Press again to trigger the distance measurement. The measured value is
displayed immediately.
Continous Measurement & Max / Min Measurement
The continuous measurement function (tracking) is used for the transferring of measurements, e.g., from construction plans. In continuous measurement mode, the measuring tool can be moved to the target, whereby the measured value is updated approx. every 0,5 seconds in the third line. The corresponding minimum and maximum values are displayed dynamically in the first and second line. As an example, the user can move from a wall to the required distance, while the actual distance can be read continuously. For continuous measurement, push the “ON/MEAS”-button (1) until the min/max symbol is displayed or the “Clear/Off”-button (5) again to stop the function.
Addition/Subtraction of Areas
Make your desired distance measurement. The next length measurement is added to the previous measurement with the “+” – button (2) or subtracted from the previous measured value with the “-” key (7) value. After the addition / subtraction, the system automatically switches back to the normal measurement mode.
Addition/Subtraction of Areas
Set the meter to Area Calculation via the corresponding key (3).
Measure the first area until the calculation is shown in the main display
(Figure 1).
Click the “+” – button (2) and carry out the second area measurement (Figure 2).
Finally, press the “Meas” key (1) and the added measurement of both areas is displayed.
For the subtraction of surfaces, proceed as described above, just by pressing the “-” – button (7) instead of the “+” – button (2)
Area Measurement
Press the “Area- / Volume” button (3).
The area symbol appears on the display:
Press the “ON/MEAS” key (1) for the first length measurement (eg length).
Press the “ON/MEAS” key (1) again for the second length measurement (eg
width).
The result of the area measurement is shown in the third line, the individual
measured values are displayed in lines 1 and 2.
Volume Measurement
Press for volume measurement the “Area- / Volume” button (3) twice until the symbol for volume measurement appears in the display:
Press the “ON/MEAS” key (1) for the first distance measurement (eg length) and
then, again the “ON / MEAS” key (1) for the second distance measurement (eg
width). The result of the area measurement of already measured values will be
displayed in the main display.
Press the “ON/MEAS” key (1) again to measure the third distance(eg height).
The value is displayed in the third line.
The result of the volume measurement will be shown in the main line, the three
previously measured readings are displayed in rows 1, 2 and 3.
Pythagorean measurement
- Indirect measurement for determining a distance (x) using 2 auxiliary measurements.
Example: Measuring heights at which the measurement of two or three
measurements is required. Follow these steps: Press the “Pythagorean” button
(8). The display shows The distance to be measured (a) flashes in the symbol.
Aim at the upper point and make the measurement.
After the first measurement the value is adopted. Now the second distance to
be measured (b) flashes. Keep the instrument as horizontal as possible.
Press the “ON/MEAS” key (1) to measure the distance of the horizontal point.
The result of the function (x) is displayed in the summary line.
- To determine the hypotenuse (x) press the “Pythagorean” button (8) again until the icon for the cathetus (a) flashes:
Measure to the first cathetus (a) with the “ON/MEAS” key (1). Then flashes the second cathetus (b) that you measure with the “ON/MEAS” key (1). In the main line now the result of the hypotenuse (x) is displayed.
Indirect Measurement – length (x) using 3 Measurements
- Press the “Pythagoras” button (8) three times until the indicator
for “indirect measurement by three readings” switches to:
The distance to be measured (a) flashes in the symbol. Aim at the upper point of the measured distance (x) and trigger the measurement of the distance (a). After the first measurement the value is adopted. Measure the distance (b) the lower point of the track (x) and press the “ON/MEAS” key (1). The second value is now displayed. Keep the instrument as horizontal as possible now. Press the “ON/MEAS” key (1) to the distance (c) measure. The result of the function (x) is shown in the summary line.
- 2. To measure the total length (x) of two short sides using three related measurements:
Press the “Pythagoras” button (8) four times, until the display for indirect
measurement switches through the three readings. The distance to be measured
(a) flashes in the symbol. Aim at the upper point of the measured distance (x)
and trigger the measurement of the distance (a). After the first measurement
the value is adopted. Measure the distance (b). Keep the instrument as
horizontal as possible and then press the “ON/MEAS” key (1). Press the
“ON/MEAS” key (1) to measure the distance (c) the lower point of the track
(x).
The result of the function (x) is shown in the summary line.
Readings memory
In order to store a displayed measurement value to the internal memory of 99
readings, press the “Memory” button (9) for about 3 seconds until the memory
icon appears. Go on as necessary, with all to be saved measurements and
continue until the memory is exhausted.
To recall a stored measured value, press and release the “Memory” button (9)
briefly. The requested measured value is now displayed in the main line, where
the storage number (1 – 99) is shown in the upper left corner of the display.
Switch trough the stored values with the “+” and “-” keys.
To delete a stored measured value, press the “Off/Clear” button (5).
Stacking Out – Preset distance
If you want to preset a certain measuring distance determined and then for example change the distance between the laser distance meter on a moving platform, hold down the “Area/ Volume” button (3) until the stacking icon appears in the display:
Change the value of the distance (a) with the “-” and “+” – keys and confirm the value with the “ON/MEAS” key (1). Now change the value for the flashing second distance (b) also with the keys “-” and “+”. Confirm again with “ON/MEAS” key (1). Now the distance measurement starts, which shows the remaining distance to reach the selected distance in the main display. If the meter is placed too far away from the set value, an icon appears that you should move forward. Are you too close, an icon appears and shows you to move backwards:
Move forwards:
Move backwards:
Once the desired distance achieved following symbol appears:
Delayed Measurement
In order to trigger a time-delayed measurement, hold down the button (4) until the timing seconds-selection of the time delay is displayed:
Now use the “-” and “+” – buttons to set the seconds to the time delayed measurement and confirm by pressing the “ON/MEAS” key (1). Now begins a countdown to zero, in which the measurement is initiated
Measuring Conditions
Measuring Range
The range is limited to 60 m (P 2801) or 80m (P 2802). At night or dusk and if
the target is in shadows the measuring range without target plate is
increased. Use a target plate to increase the measurement range during
daylight or if the target has poor reflection properties.
Target Surfaces
Measuring errors can occur when measuring toward colorless liquids (e.g.
water) or dust free glass, Styrofoam or similar semipermeable surfaces. Aiming
at high gloss surfaces may deflect the laser beam and lead to measurement
error.
Against non-reflective and dark surfaces the measuring time may increase.
Care
Do not immerse the instrument in water. Wipe off dirt with a damp, soft cloth.
Do not use aggressive cleaning agents or solutions. Handle the instrument as
you would a telescope or camera.
Troubleshooting
Code | Cause | Corrective measure |
---|---|---|
Err1 | Received signal too weak, measurement time too long. | Use target plate |
Err2 | Received signal too strong | Target too reflective (use target plate) |
Err3 | Battery weak | Replace batteries |
Err4 | Temperature too high / Low | Cool down or warm up the |
instrument
Err5| Pythagorean meas. error| Hypotenuse must be longer than Cathete
Err6| Record damaged| Switch on/off the device several times, if the symbol
still appears, please contact your dealer for assistance.
Battery Replacement
When it is necessary to replace the battery, battery-symbol will appear on the display.
-
Remove battery compartment lid
-
Insert batteries, observing correct polarity.
-
Close the battery compartment again.
If the instrument is not be used for any extended period, remove batteries.
Notification about the Battery Regulation
The delivery of many devices includes batteries, which for example serve to
operate the remote control. There also could be batteries or accumulators
built into the device itself. In connection with the sale of these batteries
or accumulators, we are obliged under the Battery Regulations to notify our
customers of the following:
Please dispose of old batteries at a council collection point or return them
to a local shop at no cost. The disposal in domestic refuse is strictly
forbidden according to the Battery Regulations.
You can return used batteries obtained from us at no charge at the address on
the last side in this manual or by posting with sufficient stamps.
Contaminated batteries shall be marked with a symbol consisting of a crossed-
out refuse bin and the chemical symbol (Cd, Hg or Pb) of the heavy metal which
is responsible for the classification as pollutant:
- “Cd” means cadmium.
- “Hg” means mercury.
- “Pb” stands for lead.
All rights, also for translation, reprinting and copy of this manual or parts
are reserved. Reproduction of all kinds (photocopy, microfilm or other) only
by written permission of the publisher.
This manual considers the latest technical knowing. Technical changings which
are in the interest of progress reserved.
We herewith confirm, that the units are calibrated by the factory according to
the specifications as per the technical specifications. We recommend to
calibrate the unit again, after 1 year.
Customer Support
PeakTech Prüf- und Messtechnik GmbH – Gerstenstieg 4 – DE22926 Ahrensburg /
Germany
+49 (0) 4102 97398-80 +49 (0) 4102 97398-99
info@peaktech.de
www.peaktech.de
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>